You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 35 Next »

 

This example shows a discrete aneurysm in the aorta. In this instance, the MRI imagining identified the presence of an aneurysm in the chest of a subject, which is in the aorta (RESLOC), extending from the aortic arch to the abdominal aorta (RLOCTX).


Rows 1-2:Show the presence of a single aortic aneurysm.
Rows 3-4:Show the aneurysm is 7.5cm in length, which is measured from the aortic arch to the abdominal aorta and 3.7cm in width.

 

$titleHtml

cv.xpt

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVGRPID

CVTEST

CVORRES

 CVORRESU

CVLOC

CVMETHOD

VISITNUM

VISIT

CVDTC

 CVRESLOC 1CVRESLOC 1

CVRLOCTX

 1  ABC CV  ABC-123 11Aneurysm Indicator Y CHESTMRI1BASELINE 2020-04-27  
 
 2  ABC CV  ABC-123 21Number of Aneurysms 1 CHESTMRI1BASELINE 2020-04-27  
 
 3  ABC CV  ABC-123 31Aneurysm Length/Diameter 7.5 CMCHESTMRI1BASELINE 2020-04-27 AORTA
Aortic Arch to Abdominal Aorta
4  ABC CV  ABC-45612Aneurysm IndicatorY
ABDOMINAL CAVITYMRI1BASELINE2020-04-27



5  ABC CV  ABC-45622Number of Aneurysms2
ABDOMINAL CAVITYMRI1BASELINE2020-04-27
RENAL ARTERYABDOMINAL AORTA

Dataset Debug Message

There is a duplicate variable (CVRESLOC 1) in the dataset.


Dataset Wrapper Debug Message

Please add a row column to your dataset.

 


 

 

 

This example shows the minor axis cross-sectional diameter measurements of the left and right ventricle of the heart, at end ventricular diastole.


Row 1:Shows the cross-sectional diameter of the left ventricle at end ventricular diastole, measured along the minor axis and specifically at the location of the high papillary muscle. The further anatomical details at which the measurement is set and performed is represented by the CVLOCTX NSV.
Row 2:Shows the cross-sectional diameter of the right ventricle at end ventricular diastole, measured along the minor axis and specifically at just below the tricuspid valve. The further anatomical details at which the measurement is set and performed is represented by the CVLOCTX NSV.
$titleHtml

cv.xpt

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVTESTCD

CVTEST

CVORRES

 CVORRESU

CVLOC

CVMETHOD

VISITNUM

VISIT

CVDTC

 

CVLOCTX

1 ABC CV ABC-123 1MNDIAEVDMinor Axis Cross-sec Diameter, EVD 3.7 CMHEART, LEFT VENTRICLETTE1BASELINE  High papillary muscle level
 2 ABC CV ABC-123 2MNDIAEVDMinor Axis Cross-sec Diameter, EVD 3.2 CmHEART, RIGHT VENTRICLETTE1BASELINE  Below the tricuspid valve
$warningHtml

 

 

Dataset Wrapper Debug Message

Please add a row column to your dataset.

 


 

 

 

 

 

  • No labels