Types of Aortic Aneurysm

Renal Artery Aneurysm

Growing Right Renal Artery Aneurysm - Endovascular Today


Often times when patients complain about chest discomforts and pain, the occurrence of aneurysm(s) are suspected. It is difficult to pinpoint the exact location of the aneurysm. Hence MRI and CT scan are the most frequently used tools to detect the presence and location of aneurysms. In this scenario, the test locations are often broadly defined as the subject's chest, abdominal cavity or the whole body. The specific location(s) where aneurysms are identified/found should be mapped to result location, not test.


Rows 1-2:Show subject ABC-123 has a single aortic aneurysm from a chest CT scan.
Row 3:Shows the said aneurysm is 7.5cm in length (diameter), which is measured from the Aortic Arch to Descending Aorta
Rows 4-5:Show subject ABC-456 is found to have aneurysms in two locations from a whole-body MRI Scan: RENAL ARTERY and THORACIC AORTA.

 

$titleHtml

cv.xpt

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVGRPID

CVTEST

CVORRES

 CVORRESU

CVTSTLOC

CVMETHOD

VISITNUM

VISIT

CVDTC


CVRESLOC1CVRESLOC2

CVRLODTL

 1  ABC CV  ABC-123 11Aneurysm Indicator Y
CHESTCT SCAN1BASELINE 2020-04-27
AORTA

 2  ABC CV  ABC-123 21Number of Aneurysms 1
CHESTCT SCAN1BASELINE 2020-04-27
AORTA

 3  ABC CV  ABC-123 31Aneurysm Length/Diameter 7.5 CMCHESTCT SCAN1BASELINE 2020-04-27
AORTA
Aortic Arch to Descending Aorta
4  ABC CV  ABC-45612Aneurysm IndicatorY
BODYMRI1BASELINE2020-04-27
RENAL ARTERYTHORACIC AORTA
5  ABC CV  ABC-45622Number of Aneurysms2
BODYMRI1BASELINE2020-04-27
RENAL ARTERYTHORACIC AORTA
$warningHtml


Dataset Wrapper Debug Message

Please add a row column to your dataset.


From the CV-imaging project we also encountered use-cases where we need sub-LOC variables to help to further specify the free-text, detailed, more granular locations where a test is performed. These values are indeed clinically relevant location information that should NOT be pre-coordinated into the TEST itself, but are also inappropriate for LOC.

So we need a variable that provides additional, more specific and granular information about a proximate location or a range of location(s).


 

This example shows the minor axis cross-sectional diameter measurements of the left and right ventricle of the heart, at end ventricular diastole.


Row 1:Shows the cross-sectional diameter of the left ventricle at end ventricular diastole, measured along the minor axis and specifically at the location of the high papillary muscle. The more granular, free-text anatomical description at which the measurement is set and performed is represented by the CVTLODTL NSV.
Row 2:Shows the cross-sectional diameter of the right ventricle at end ventricular diastole, measured along the minor axis and specifically at just below the tricuspid valve. The more granular, free-text anatomical description at which the measurement is set and performed is represented by the CVTLODTL NSV.
$titleHtml

cv.xpt

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVTESTCD

CVTEST

CVORRES

 CVORRESU

CVTSTLOC

CVMETHOD

VISITNUM

VISIT

CVDTC


CVTLODTL

1 ABC CV ABC-123 1MNDIAEVDMinor Axis Cross-sec Diameter, EVD 3.7 CMHEART, LEFT VENTRICLETTE1BASELINE

At high papillary muscle level
 2 ABC CV ABC-123 2MNDIAEVDMinor Axis Cross-sec Diameter, EVD 3.2 CmHEART, RIGHT VENTRICLETTE1BASELINE

Below the tricuspid valve
$warningHtml

 


Dataset Wrapper Debug Message

Please add a row column to your dataset.








  • No labels

1 Comment

  1. How a thoric arotic dissection maybe collected on a ECHO report:

    Dissection is measured 3mm from the superior margin of the aneurysm