The procedures (PR) domain contains interventional activity intended to have diagnostic, preventive, therapeutic, or palliative effects. The example PR dataset below shows the cardiac magnetic resonance imaging with two different MRI machines (PRTRT=MRI and PRLOC=HEART). The sponsor device identifier (SPDEVID) variable is used to represent the imaging device identifier information provided in the DI dataset below.
Row 1:
Shows the results of a cardiac MRI for participant DMD-LGE-01-201.
Row 2:
Shows the results of a cardiac MRI for participant DMD-LGE-01-202 with a different MRI machine. The time of the procedure was not available so only the date is shown in the PRSTDTC variable.
pr.xpt
pr.xpt
Row
STUDYID
DOMAIN
USUBJID
PRSEQ
SPDEVID
PRREFID
PRLNKID
PRTRT
PRLOC
PRFAST
PRSTDTC
1
DMD-EFLGE
PR
DMD-LGE-01-201
1
ABC001
12345678
04
MRI
HEART
Y
2023-07-01T09:15:00
2
DMD-EFLGE
PR
DMD-LGE-01-202
1
ABC002
98765432
05
MRI
HEART
N
2023-07-05
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
The example CV dataset below showsthe results of the LGE test measured using CMR imaging. The analysis method describes the method of secondary processing applied to a complex observation result (e.g., an image, a genetic sequence). There may be machine-centric analysis methods inherit to the type of machine (e.g., full-width half maximum, 5 standard deviations, 6 standard deviations). (Ref: https://jcmr-online.biomedcentral.com/articles/10.1186/1532-429X-12-21). If this information is of interest to the study, it would be represented using the CVANMETH variable.
Row 1:
Shows that LGE is positive for participant DMD-LGE-01-201.
Row 2:
Shows the total LGE percentage is 40%.
Rows 3-19:
Show the segmental LGE results for each of the left ventricle segments.
Row 20:
Shows the LGE segment count.
Rows 21-24:
Show the segmental LGE percentage for each of the positive segments.
Row 25:
Shows that LGE is negative for participant DMD-LGE-01-202.
cv.xpt
cv.xpt
Row
STUDYID
DOMAIN
USUBJID
CVSEQ
CVLNKID
CVTESTCD
CVTEST
CVORRES
CVORRESU
CVSTRESC
CVSTRESN
CVSTRESU
CVLOC
CVMETHOD
CVLOBFXL
CVANMETH
VISITNUM
VISIT
CVDTC
1
DMD-EFLGE
CV
DMD-LGE-01-201
1
04
LGE
LATE GADOLINIUM ENHANCEMENT
POSITIVE
POSITIVE
HEART, LEFT VENTRICLE
MRI
VISUAL
1
VISIT 1
2023-07-01
2
DMD-EFLGE
CV
DMD-LGE-01-201
2
04
LGEPER
LATE GADOLINIUM ENHANCEMENT PERCENTAGE
40
%
40
40
%
HEART, LEFT VENTRICLE
MRI
QUANTITATIVE
1
VISIT 1
2023-07-01
3
DMD-EFLGE
CV
DMD-LGE-01-201
3
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR BASAL ANTERIOR SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
4
DMD-EFLGE
CV
DMD-LGE-01-201
4
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
POSITIVE
POSITIVE
LEFT VENTRICULAR BASAL ANTEROLATERAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
5
DMD-EFLGE
CV
DMD-LGE-01-201
5
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
POSITIVE
POSITIVE
LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
6
DMD-EFLGE
CV
DMD-LGE-01-201
6
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR BASAL INFERIOR SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
7
DMD-EFLGE
CV
DMD-LGE-01-201
7
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR BASAL INFEROLATERAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
8
DMD-EFLGE
CV
DMD-LGE-01-201
8
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
9
DMD-EFLGE
CV
DMD-LGE-01-201
9
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR MID ANTERIOR SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
10
DMD-EFLGE
CV
DMD-LGE-01-201
10
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
POSITIVE
POSITIVE
LEFT VENTRICULAR MID ANTEROSEPTAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
11
DMD-EFLGE
CV
DMD-LGE-01-201
11
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
POSITIVE
POSITIVE
LEFT VENTRICULAR MID INFEROSEPTAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
12
DMD-EFLGE
CV
DMD-LGE-01-201
12
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR MID INFERIOR SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
13
DMD-EFLGE
CV
DMD-LGE-01-201
13
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR MID INFEROLATERAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
14
DMD-EFLGE
CV
DMD-LGE-01-201
14
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR MID ANTEROLATERAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
15
DMD-EFLGE
CV
DMD-LGE-01-201
15
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR APICAL ANTERIOR SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
16
DMD-EFLGE
CV
DMD-LGE-01-201
16
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR APICAL SEPTAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
17
DMD-EFLGE
CV
DMD-LGE-01-201
17
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR APICAL INFERIOR SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
18
DMD-EFLGE
CV
DMD-LGE-01-201
18
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR APICAL LATERAL SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
19
DMD-EFLGE
CV
DMD-LGE-01-201
19
04
SGELGE
SEGMENTAL LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
LEFT VENTRICULAR APEX SEGMENT
MRI
VISUAL
1
VISIT 1
2023-07-01
20
DMD-EFLGE
CV
DMD-LGE-01-201
20
04
LGESEGCT
LATE GADOLINIUM ENHANCEMENT SEGMENT CT
4
4
4
HEART, LEFT VENTRICLE
MRI
VISUAL
1
VISIT 1
2023-07-01
21
DMD-EFLGE
CV
DMD-LGE-01-201
21
04
LGEPER
LATE GADOLINIUM ENHANCEMENT PERCENTAGE
40
%
40
40
%
LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT
MRI
FULL-WIDTH HALF MAXIMUM
1
VISIT 1
2023-07-01
22
DMD-EFLGE
CV
DMD-LGE-01-201
22
04
LGEPER
LATE GADOLINIUM ENHANCEMENT PERCENTAGE
20
%
20
20
%
LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT
MRI
FULL-WIDTH HALF MAXIMUM
1
VISIT 1
2023-07-01
23
DMD-EFLGE
CV
DMD-LGE-01-201
23
04
LGEPER
LATE GADOLINIUM ENHANCEMENT PERCENTAGE
45
%
45
45
%
LEFT VENTRICULAR MID ANTEROSEPTAL SEGMENT
MRI
FULL-WIDTH HALF MAXIMUM
1
VISIT 1
2023-07-01
24
DMD-EFLGE
CV
DMD-LGE-01-201
24
04
LGEPER
LATE GADOLINIUM ENHANCEMENT PERCENTAGE
20
%
20
20
%
LEFT VENTRICULAR INFEROSEPTAL SEGMENT
MRI
FULL-WIDTH HALF MAXIMUM
1
VISIT 1
2023-07-01
25
DMD-EFLGE
CV
DMD-LGE-01-202
1
05
LGE
LATE GADOLINIUM ENHANCEMENT
NEGATIVE
NEGATIVE
HEART, LEFT VENTRICLE
MRI
VISUAL
1
VISIT 1
2023-07-05
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
The procedure agents (AG) domain contains the agents administered to the subject as part of a procedure or assessment. The example AG dataset below shows the timing of the gadolinium-based contrast, 'Gd-DOTA'. The time the contrast was given to participant DMD-LGE-01-202 was not available, so only the date is represented in AGSTDTC variable.
ag.xpt
ag.xpt
Row
STUDYID
DOMAIN
USUBJID
AGSEQ
AGLNKID
AGTRT
AGCAT
AGDOSE
AGDOSU
AGDOSFRM
AGROUTE
VISITNUM
AGSTDTC
1
DMD-EFLGE
AG
DMD-LGE-01-201
1
04
Gd-DOTA
CONTRAST AGENT
8
mL
SOLUTION
INTRAVENOUS
VISIT 1
2023-07-01T09:25:00
2
DMD-EFLGE
AG
DMD-LGE-01-202
2
04
Gd-DOTA
CONTRAST AGENT
10
mL
SOLUTION
INTRAVENOUS
VISIT 1
2023-07-05
$warningHtml
The device identifiers (DI) domain is used to represent the device information details. For this particular example, the device type was the only detail of interest to the researchers. The sequence number (DISEQ) is specific to each device; note there are two different CMR scanners noted with different values in the SPDEVID variable. Each scanners has a value of "1" for the DISEQ variable since there is only one record or row for each device.