In this study, subjects were randomized to different doses of a nicotine inhaler. The recommended usage instructions for the nicotine inhaler were provided to the subject at each visit. At visits 1-3, subjects were to use 6-10 cartridges per day, and during visits 4-6 subjects were to use 3-6 cartridges per day. Subjects were encouraged not to use any other tobacco products, nicotine replacement therapies or alcohol during the study. Data on usage of these products were collected using an e-diary, where the subject provided information on the products used each day. Only days where a product was used were represented.
Alcohol usage and tobacco product usage were represented in the SU domain. SUCAT allows the records to be grouped into tobacco-related data and alcohol related data. In this example, the products were prespecified so SUTRT does not require a standardized SUDECOD equivalent. The sponsor only includes SUSTDTC and SUENDTC as timing variables.
Row 1:
Shows the cigarettes used for the day of assessment. SUDOSFRQ was represented using the controlled terminology for per day, QD.
Rows 2-3:
Show 2 other records for a subject's usage of tobacco products on two other days.
Row 4:
Shows the subject's use of alcohol. Note, the sponsor collected the ounces of the product used using a pre-specified amount per drink.
su.xpt
xx.xpt
Row
STUDYID
DOMAIN
USUBJID
SUSEQ
SUTRT
SUCAT
SUDOSE
SUDOSU
SUDOSFRQ
SUSTDTC
SUENDTC
1
TIN111
SU
TIN701
1
CIGARETTE
TOBACCO
1
CIGARETTE
QD
2020-06-26
2020-06-26
2
TIN111
SU
TIN701
2
CIGAR
TOBACCO
2
CIGAR
QD
2020-07-27
2020-07-27
3
TIN111
SU
TIN801
1
CIGARETTE
TOBACCO
1
CIGARETTE
QD
2020-07-15
2020-07-15
4
TIN111
SU
TIN801
2
BEER
ALCOHOL
24
OZ
QD
2020-07-20
2020-07-20
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
Drugs used to treat nicotine dependency are considered drugs and were represented in the Concomitant Medication (CM) domain. This subject used a 14 mg nicotine replacement patch. The sponsor included the CMCLASS, CMDECOD, and CMMODIFY. These were included to reflect standardized coding of the medication.
cm.xpt
cm.xpt
Row
STUDYID
DOMAIN
USUBJID
CMSEQ
CMTRT
CMMODIFY
CMDECOD
CMCLAS
CMDOSE
CMDOSU
CMDOSFRM
CMSTDTC
CMENDTC
1
TIN111
CM
TIN701
1
Nicotine Replacement Patch
Nicotine
NICOTINE
DRUGS USED IN NICOTINE DEPENDENCE
14
mg
PATCH
2020-06-26
2020-06-27
$warningHtml
A Product Accountability (DA) domain was used to represent the amount of study product transferred to or from the study subjects. At each visit, each subject was supplied with 90 cartridges per week for weeks 1-3, and 50 cartridges per week for weeks 4-6. The number of cartridges returned were counted. DACAT was used to indicate that the product of interest was the study product. DASPID and DAREFID can be used for code numbers that appeared on the study product label, in this case no code numbers were included on the labels. The sponsor included VISITNUM and DADTC as these variables are expected in this domain. DADTC was the date the supplies were dispensed or returned, these corresponded to the dates of the visits.
Rows 1, 3:
Show the number of cartridges dispensed to the subject.
Rows 2, 4:
Show the number of cartridges returned by the subject.
da.xpt
da.xpt
Row
STUDYID
DOMAIN
USUBJID
DASEQ
DATESTCD
DATEST
DACAT
DAORRES
DAORRESU
DASTRESC
DASTRESN
DASTRESU
VISITNUM
DADTC
1
TIN111
DA
TIN701
1
DISPAMT
Dispensed Amount
STUDY PRODUCT
90
CARTRIDGE
90
90
CARTRIDGE
1
2004-06-26
2
TIN111
DA
TIN701
2
RETAMT
Returned Amount
STUDY PRODUCT
13
CARTRIDGE
13
13
CARTRIDGE
2
2020-07-06
3
TIN111
DA
TIN701
3
DISPAMT
Dispensed Amount
STUDY PRODUCT
50
CARTRIDGE
50
50
CARTRIDGE
2
2020-07-06
4
TIN111
DA
TIN701
4
RETAMT
Returned Amount
STUDY PRODUCT
10
CARTRIDGE
10
10
CARTRIDGE
3
2020-07-14
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
The sponsor used a patient diary (not shown here) to determine how many cartridges the subject used on each day, then created the EC data shown below to represent the collected exposure data. The usage recommendations were represented in ECDOSRGM, which is the intended Dose Regimen. The ECMOOD permissible variable was used to reflect the prescribed and the actual usage of the inhaled nicotine. When this variable is used, it must be populated for all records. This variable cannot be used in EX.
Row 1:
Shows the scheduled usage recommendation for the inhaled nicotine. Note, the details on the scheduled records are described at a different level than the performed records. ECDOSRGM shows that for these start and end dates the subject was recommended to use 6-12 cartridges every day.
Rows 2, 3:
Show the actual "performed" amount of inhaled nicotine used by the subject each day. Note only a few rows of the performed records are shown.
Row 4:
Shows the scheduled usage recommendation for the inhaled nicotine. ECDOSRGM shows for these start and end dates the subject was recommended to use 3-6 cartridges per day..
Row 5:
Shows the actual "performed" amount of inhaled nicotine used by the subject each day. Note only a few rows of the performed records are shown.
ec.xpt
ec.xpt
Row
STUDYID
DOMAIN
USUBJID
ECSEQ
ECTRT
ECMOOD
ECDOSE
ECDOSU
ECDOSFRM
ECDOSRGM
ECROUTE
EPOCH
ECSTDTC
ECENDTC
1
TIN111
EC
TIN701
1
INHALED NICOTINE
SCHEDULED
CARTRIDGE
CARTRIDGE
6 -10 cartridges per day
RESPIRATORY (INHALATION)
PRODUCT EXPOSURE
2004-06-26
2004-07-06
2
TIN111
EC
TIN701
2
INHALED NICOTINE
PERFORMED
7
CARTRIDGE
CARTRIDGE
RESPIRATORY (INHALATION)
PRODUCT EXPOSURE
2004-06-26
2004-06-26
3
TIN111
EC
TIN701
3
INHALED NICOTINE
PERFORMED
2
CARTRIDGE
CARTRIDGE
RESPIRATORY (INHALATION)
PRODUCT EXPOSURE
2004-06-27
2004-06-27
4
TIN111
EC
TIN701
4
INHALED NICOTINE
SCHEDULED
CARTRIDGE
CARTRIDGE
3-6 cartridges per day
RESPIRATORY (INHALATION)
PRODUCT EXPOSURE
2004-07-06
2004-07-14
5
TIN111
EC
TIN701
5
INHALED NICOTINE
PERFORMED
3
CARTRIDGE
CARTRIDGE
RESPIRATORY (INHALATION)
PRODUCT EXPOSURE
2004-07-07
2004-07-07
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
The EX dataset shows the actual administrations. Note the scheduled records are not included. Only a few rows are shown for illustration. The pharmaceutical strength was included to identify the dose of the nicotine inhaler used by the subject. Since EXENDTC is an expected variable, the sponsor populated this timing variable with the start date.