Tobacco product HPHC testing results are represented in the PT domain. This example shows HPHC testing with an ENDS device.HPHC testing is conducted on samples of the product of interest, and (if applicable) samples of comparison products. Each product tested would have its own unique sponsor-defined value for SPTOBID to identify the product.
The following references were used as guidance for the example below:
Show the HPHC testing performed for two constituents on Batch 1, Replication 1 for the liquid matrix. The CAS number of the constituent is provided in PTCAS.
Rows 3-5:
Shows the HPHC testing performed for three constituents using the NON-INTENSE SMOKING REGIME for BATCH 1 and Replicate 1.
Rows 6-7:
Shows the HPHC testing performed for three constituents using the INTENSE SMOKING REGIME for BATCH 1 and Replicate 1.
Row Captions Debug Message
Remember to keep number agreement between labels and captions.
pt.xpt
pt.xpt
Row
STUDYID
DOMAIN
SPTOBID
SPDEVID
PTSEQ
PTREFID
PTSPID
PTCAS
PTTESTCD
PTTEST
PTCAT
PTSCAT
PTORRES
PTORRESU
PTSTRESC
PTSTRESN
PTSTRESU
PTSPEC
PTMETHOD
PTREPNUM
PTDTC
1
TOB08
PT
ENDS02a
1
Batch 101
since we started with using PTREFID for the Smoking Regimen in the Cig. example, The batch number could go here. It seems like Smoking Regimen is a method though.
The identifying characteristics of the smoking machine are represented in the Device Identifiers reference dataset.
di.xpt
di.xpt
Row
STUDYID
DOMAIN
SPDEVID
DISEQ
DIPARMCD
DIPARM
DIVAL
1
TOB07
DI
PUFFMASTER3K
1
DEVTYPE
Device Type
Smoking Machine
2
TOB07
DI
PUFFMASTER3K
2
MANUF
Manufacturer
Acme
3
TOB07
DI
PUFFMASTER3K
3
TRADENAM
Trade Name
PuffMaster 3000
$warningHtml
Details of the smoking regimen performed by the smoking machine are represented as device in-use properties, linked to the HPHC testing results in PT above by matching values of PTREFID/DUREFID = "Non-intense Regimen".