This example has been updated according to the approached discussed on the team call on 1/17. Additionally, we have simplified the Tobacco Product Identifiers and Descriptors (TO) domain by using parameters (TOPARM) instead of tests (TOTEST)
This images shows the filtration zone where the ventilation occurs.
Question - is this helpful? Will need permission. This is from the second reference.
The following example illustrates the representation of cigarette product design parameter specifications using the PD domain. First, the TO example below shows the identifiers and descriptors associated with this product.
Rows 1-4:
Show the records for the product identifiers for the tobacco product identified in SPTOBID. These records are categorized as product identifiers by TOCAT = PRODUCT IDENTIFIERS.
Rows 5-10:
Show the records for the product descriptors for the tobacco product identified in SPTOBID. These records are categorized as product identifiers by TOCAT = PRODUCT DESCRIPTOR.
to.xpt
to.xpt
Row
STUDYID
DOMAIN
SPTOBID
TOSEQ
TOPARMCD
TOPARM
TOCAT
TOVAL
TOVALU
1
TOB07
TO
CIG01a
1
TBPRDCAT
Tobacco Product Category
PRODUCT IDENTIFIER
Cigarette
2
TOB07
TO
CIG01a
2
TBPRSCAT
Tobacco Product Subcategory
PRODUCT IDENTIFIER
Filtered, Combusted
3
TOB07
TO
CIG01a
3
MANUF
Manufacturer
PRODUCT IDENTIFIER
Joes Cigs USA
4
TOB07
TO
CIG01a
4
TRADENAM
Trade Name
PRODUCT IDENTIFIER
Treetop Menthol King Size
5
TOB07
TO
CIG01a
5
PACKTYP
Package Type
PRODUCT DESCRIPTOR
HARD PACK
6
TOB07
TO
CIG01a
6
PRDQUAN
Product Quantity
PRODUCT DESCRIPTOR
20
CIGARETTE
7
TOB07
TO
CIG01a
7
LENGTH
Length
PRODUCT DESCRIPTOR
86.0
mm
8
TOB07
TO
CIG01a
8
CIRCUMF
Circumference
PRODUCT DESCRIPTOR
26.0
mm
9
TOB07
TO
CIG01a
9
VENTLTN
Ventilation
PRODUCT DESCRIPTOR
10.0
%
10
TOB07
TO
CIG01a
10
CHARFLAV
Characterizing Flavor
PRODUCT DESCRIPTOR
MENTHOL
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
The manufacturing parameter specifications of the tobacco product as used are represented in the Product Design Parameters (PD) domain The example below shows the target, minimum, and maximum values associated with each of 19 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.
pd.xpt
pd.xpt
Row
STUDYID
DOMAIN
SPTOBID
PDSEQ
PDPARMCD
PDPARM
PDVALTRG
PDVALMIN
PDVALMAX
PDVALU
1
TOB07
PD
CIG01a
1
LENGTH
Length
84
83.5
84.5
mm
2
TOB07
PD
CIG01a
2
CIRCUMF
Circumference
24.8
24.6
25
mm
3
TOB07
PD
CIG01a
3
TBFLMASS
Tobacco Filler Mass
783
753
814
mg
4
TOB07
PD
CIG01a
4
MOISTURE
Moisture
14
12.09
13.91
%
5
TOB07
PD
CIG01a
5
TOCUTSIZ
Tobacco Cut Size
22
20
24
cuts/in2
6
TOB07
PD
CIG01a
6
TOCUTSIZ
Tobacco Cut Size
27
25
29
mm
7
TOB07
PD
CIG01a
7
FLTRVENT
Filter Ventilation
30
23
37
%
8
TOB07
PD
CIG01a
8
TPNPLGTH
Tipping Paper Length
31
30
32
mm
9
TOB07
PD
CIG01a
9
CIGBPPOR
Cigarette Base Paper Porosity
NA
NA
NA
CORESTA Unit (Cu)
10
TOB07
PD
CIG01a
10
CIGBPPOR
Cigarette Base Paper Permeability
50
45
55
CORESTA Unit (Cu)
11
TOB07
PD
CIG01a
11
BNDPOR
Cigarette Paper Band Porosity
NA
NA
NA
CORESTA Unit (Cu) or cm2/s
12
TOB07
PD
CIG01a
12
BNDPERM
Cigarette Paper Band Permeability
10
0.2
13
CORESTA Unit (Cu) or cm2/s
13
TOB07
PD
CIG01a
13
BNDDIF
Cigarette Paper Band Diffusivity
NA
NA
NA
CORESTA Unit (Cu) or cm2/s
14
TOB07
PD
CIG01a
14
CPBNDWID
Cigarette Paper Band Width
7
6.7
7.3
mm
15
TOB07
PD
CIG01a
15
CPBNDSPC
Cigarette Paper Band Space
20
19.8
20.2
mm
16
TOB07
PD
CIG01a
16
FLTREFF
Filter Efficiency
NA
N/A
N/A
%
17
TOB07
PD
CIG01a
17
DPF
Denier Per Filament
4
3.6
4.4
4
18
TOB07
PD
CIG01a
18
TDENIER
Total Denier
30000
29100
30900
g/9000 m
19
TOB07
PD
CIG01a
19
FLTRDEN
Filter Density
0.1234
0.105
0.1419
g/cm3
20
TOB07
PD
CIG01a
20
FLTRLGTH
Filter Length
25
24.5
25.5
mm
21
TOB07
PD
CIG01a
21
FLTPRDRP
Filter Pressure Drop
60
51
69
mm H2O
22
TOB07
PD
CIG01a
22
TORODDEN
Tobacco Rod Density
0.2678
0.2437
0.2919
g/cm3
23
TOB07
PD
CIG01a
23
Cigarette Paper Length
CIGPLGTH
53
52
54
mm
$warningHtml
Finally, the Tobacco Product Testing (PT) domain is used to represent the actual results of testing the manufactured product for conformance to the tobacco product design parameters shown in PD above.