You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 25 Next »

This is a study were subjects were randomized to use 3 different concentration of e-nicotine liquid, or their usual brand of cigarettes. The subject used the product at home for 2 weeks. This 2-week period allowed subjects to become familiar with the e-cigarette. After two weeks, the subjects were confined to the clinical for one day. They were required to not use any  tobacco products for 12 hours prior to the visit. Subjects had to have CO level below a pre-specified level, to attend the visit.  If the level, was too high, the visit was re-scheduled. Subjects were instructed to take 10 puffs on the e-cigarette/usual brand of cigarettes in the morning and afternoon.  Puff topography was measured in the morning and afternoon using the same device for all subjects.  Subjects were not allowed to use any tobacco products between the morning and afternoon sessions. 

A  Study Reference domain, DI, was used to identify the device used to measure puff topography.  The provide a consistent sponsor-defined variable (SPDEVID) for linking data. Device identifiers exist independently from subjects; therefore, the DI domain does not contain USUBJID. Only one device was used for all subjects in the study. 

di.xpt

di.xpt

RowSTUDYIDDOMAINSPDEVIDDISEQDIPARMCDDIPARMDIVAL
1TOPT001DIPUFANYXYZ1DEVTYPEDevice TypePUFF TOPOGRAPHER
2TOPT001DIPUFANYXYZ2MODELModelPUFFALYZER 900
3TOPT001DIPUFANYXYZ3MANUFManufacturerACME
$warningHtml
The sponsor submitted the EX domain to represent the usage of the tobacco product.  For each subject, the usage for the two weeks are represented, and then the specified usage during the in-clinic visit are shown. The sponsor elected not to represent each puff in this EX dataset. Each Puff could have been recorded.       

ex.xpt

ex.xpt

RowSTUDYIDDOMAINUSUBJIDEXSEQSPTOBIDEXLNKIDEXTRTEXDOSEEXDOSUEXROUTEEXPSTRGEXPSTRGUEXSTDTCEXENDTC
1TOPT001EX30011EC-333
e-nicotine liquidAD LIBITUM
INHALED8mg/mL2020-06-262020-07-14
2TENDS01EX30012EC-3331e-nicotine liquid10PUFFSINHALED8mg/mL2020-07-15T9:002020-07-15TT9:45
3TENDS01EX30013EC-3332e-nicotine liquid10PUFFSINHALED8mg/mL2020-07-15T3:002020-07-15TT3:45
4TENDS01EX40011EC-333
e-nicotine liquidAD LIBITUM
INHALED16mg/mL2020-09-062020-09-22
5TENDS01EX40012EC-3331e-nicotine liquid10PUFFSINHALED16mg/mL2020-09-22T9:002020-09-22T9:30
6TENDS01EX40013EC-3332e-nicotine liquid10PUFFSINHALED16mg/mL2020-09-22T3:002020-09-22T3:30
7TENDS01EX50041

Cigarettes Brand XYZAD LIBITUM
INHALED12.1mg/cigarette2020-10-082020-10-22
8TENDS01EX50042
1Cigarettes Brand XYZ10PUFFSINHALED12.1mg/cigarette2020-10-22T9:002020-09-22T9:30
9TENDS01EX50043
2Cigarettes Brand XYZ10PUFFSINHALED12.1mg/cigarette2020-10-22T3:002020-09-22T3:30
$warningHtml
The FAEX domain was used to represent the puff topography associated with the in-clinic visit. A puff -by puff analysis was performed. FATPT was used to represent the time point, in this case, AM and PM.  Typically, the sponsor derives summary results using the individual source data records, these summary results are represented in ADaM.  However, if summary results are collected on a CRF or provided by an external vendor. these derived results can be represented in FAEX using the variable FACOLSRT. In this example, the sponsor created an ADaM dataset to represent the summary data ( Not Shown). 
Rows 1, 6:Show the Number of Puff taken in the time interval specified in FADTC and FAENDTC. This was pre-specified in the design, but the sponsor reported the actual number of puffs taken.
Rows 2-5:Show the various measurements recorded for subject 3001 for Puff 1 during the morning administration of the tobacco product. FADTC and FAENDTC provides the timing of each puff. The individual puff data for the afternoon are not shown.
Rows 6-10:Show the various measurements recorded for subject 3001 for Puff 10 during the afternoon administration of the tobacco product. FADTC and FAENDTC provides the timing of each puff. The individual puff data for the morning session are not shown. Note the data for PUFFS 2-9 are not shown to save space.
Rows 12-15:Show the various measurements recorded for subject 4001. Only a few rows are shown to save space.

fa.xpt

faex.xpt

RowSTUDYIDDOMAINUSUBJIDSPDEVIDSPTOBIDFASEQFALNKIDFASPIDFATESTCDFATESTFAOBJFACATFAORRESFAORRESUFASTRESCFASTRESUVISITNUMFADTCFAENDTCFATPT
1TGI400FA3001PUFANYXYZEC-33311
PUFF TOTTotal Number of Puffse-nicotine liquid

PUFF TOPOGRAPHY

10PUFFS10PUFFS22020-07-15T09:002020-07-15TT9:45

AM

2TGI400FA3001PUFANYXYZEC-33321PUFF 1PUFFVOLPuff Volumee-nicotine liquid

PUFF TOPOGRAPHY

36.7mL/sec37mL/sec2

2020-07-15T09:01.36

2020-07-15T09:01.38

AM

3

TGI400

FA3001PUFANYXYZEC-33331PUFF 1AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY15.5mL/sec15.5mL/sec22020-07-15T09:01.362020-07-15T09:01.38AM
4

TGI400

FA3001PUFANYXYZEC-33341PUFF 1PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY20.5mL/sec20.5mL/sec22020-07-15T09:01.362020-07-15T09:01.38AM
5

TGI400

FA3001PUFANYXYZEC-33351PUFF 1PUFFDURPuff Duratione-nicotine liquidPUFF TOPOGRAPHY2.0msec1.6msec22020-07-15T09:01.362020-07-15T09:01.38AM
6TGI400FA3001PUFANYXYZEC-33362
PUFF TOTTotal Number of Puffse-nicotin liquid

PUFF TOPOGRAPHY

9PUFFS9PUFFS22020-07-15T03:002020-07-15T03:30PM
7

TGI400

FA3001PUFANYXYZEC-33372PUFF 10INTPUFINPuff Intervale-nicotine liquidPUFF TOPOGRAPHY910396.8sec910396.8sec22020-07-15T03:30:342020-07-15T03:30:36PM
8

TGI400

FA3001PUFANYXYZEC-33382PUFF 10PUFFVOLPuff Volumee-nicotine liquidPUFF TOPOGRAPHY43mL/sec43mL/sec22020-07-15T03:30:342020-07-15T03:30:36

PM

9

TGI400

FA3001PUFANYXYZEC-33392PUFF 10AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY14.5mL/sec14.5mL/sec22020-07-15T03:30:342020-07-15T03:30:36

PM

10

TGI400

FA3001PUFANYXYZEC-333102PUFF 10PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY22.5mL/sec22.5mL/sec22020-07-15T03:30:342020-07-15T03:30:36

PM

12TGI400FA4001PUFANYXYZEC-33311
PUFF TOTTotal Number of Puffse-nicotine liquid

PUFF TOPOGRAPHY

10PUFFS10PUFFS22020-08-15T9:002020-08-15TT9:45

AM

13

TGI400

FA4001PUFANYXYZEC-33321PUFF 1PUFFVOLPuff Volumee-nicotine liquidPUFF TOPOGRAPHY34.7mL/sec34mL/sec22020-08-15T09:01.362020-08-15T09:01.38AM
14

TGI400

FA4001PUFANYXYZEC-33331PUFF 1AVGFLOWAverage Flow ratee-nicotine liquidPUFF TOPOGRAPHY15.5mL/sec15.5mL/sec22020-08-15T09:01.362020-08-15T09:01.38AM
15

TGI400

FA4001PUFANYXYZEC-33341PUFF 1PKFLOWPeak Flow Ratee-nicotine liquidPUFF TOPOGRAPHY23.5mL/sec23.5mL/sec22020-08-15T09:01.362020-08-15T09:01.38AM
$warningHtml

Dataset Wrapper Debug Message

Please add a row column to your dataset.

The RELREC dataset was used to record the relationship between the Exposure records in EX and the records in FAEX.
$titleHtml

relrec.xpt

Row

STUDYID

RDOMAIN

USUBJID

IDVAR

IDVARVAL

RELTYPE

RELID

1TD23EX
EXLNKID
ONEEXFA1
2TD23FAEX
FALNKID
MANYEXFA1
$warningHtml

  • No labels