SPDEVID = SPTOBID for Sponsor Tobacco Device Identifier
DO/DU = Tobacco Design Parameters (DP)
LB = Tobacco Product Testing (TT)
This is an example for the required tobacco product categorization, property description, and design parameter information in an FDA marketing application for one type of tobacco product Cigarette. There are many more and various types of tobacco products, and their parameters can be found in the in the FDA final rule and guidance documents for tobacco products Premarket Authorization (PMTA) and Substantial Equivalence (SE) Pathways. The applicant submitting for SE and PMTAs should provide test data to include test protocols, quantitative acceptance criteria, data sets, and summary of results as applicable for these parameters.
Tobacco Products (TO) is a study reference dataset that provides a mechanism for uniquely identifying a tobacco product. It is similar to Device Identifiers (DI) in function. The primary purpose of this dataset is to provide a list of the products used in an application or study and to provide identifying information for each product, such as product category type, manufacturer, model (product) name, etc., as applicable. All identifying information is grouped by the Sponsor Tobacco Product Identifier (SPTOBID) (similar to Sponsor Device Identifier (SPDEVID) a consistent variable, that is available for use in other domains where data pertaining to the product may be found.
Steve H's suggestion of combining our previous product identifiers and product descriptors into a single dataset. This is a more traditional findings dataset structure. Advantages: it doesn't break any rules. SPTOBID is the Sponsor-defined Tobacco Product Identifier, and serves as the "subject" of all records since these are not (human) subject-level data.
Rows 1-4:
Show the records for a tobacco product identifiers that were previously represented in a separate DI dataset
Rows 5-10:
Show the product descriptors which we would have originally put in a DO-like dataset.
to.xpt
to.xpt
Row
STUDYID
DOMAIN
SPTOBID
TOSEQ
TOTESTCD
TOTEST
TOCAT
TOORRES
TOORRESU
TOSTRESC
TOSTRESN
TOSTRESU
1
TOB07
TO
CIG01a
1
TBPRDCAT
Tobacco Product Category
PRODUCT IDENTIFIER
Cigarette
Cigarette
2
TOB07
TO
CIG01a
2
TBPRSCAT
Tobacco Product Subcategory
PRODUCT IDENTIFIER
Filtered, Combusted
Filtered, Combusted
3
TOB07
TO
CIG01a
3
MANUF
Manufacturer
PRODUCT IDENTIFIER
Joes Cigs USA
Joes Cigs USA
4
TOB07
TO
CIG01a
4
TRADENAM
Trade Name
PRODUCT IDENTIFIER
Treetop Menthol King Size
Treetop Menthol King Size
5
TOB07
TO
CIG01a
5
PACKTYP
Package Type
PRODUCT DESCRIPTOR
HARD PACK
HARD PACK
6
TOB07
TO
CIG01a
6
PRDQUAN
Product Quantity
PRODUCT DESCRIPTOR
20
CIGARETTE
20
20
CIGARETTE
7
TOB07
TO
CIG01a
7
LENGTH
Length
PRODUCT DESCRIPTOR
86.0
mm
86.0
86.0
mm
8
TOB07
TO
CIG01a
8
CIRCUMF
Circumference
PRODUCT DESCRIPTOR
26.0
mm
26.0
26.0
mm
9
TOB07
TO
CIG01a
9
VENTLTN
Ventilation
PRODUCT DESCRIPTOR
10.0
%
10.0
10.0
%
10
TOB07
TO
CIG01a
10
CHARFLAV
Characterizing Flavor
PRODUCT DESCRIPTOR
MENTHOL
MENTHOL
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
The Tobacco Product Design Parameters (DP) represents the manufacturing parameter specifications of the tobacco product as used. The example below shows the target, minimum, and maximum values associated with each of 19 separate design parameters. These parameters are defined as manufacturing guidelines, not determined experimentally.
dp.xpt
dp.xpt
Row
STUDYID
DOMAIN
SPTOBID
DPSEQ
DPTESTCD
DPTEST
DPCAT
DPORRES
DPORRESU
DPSTRESC
DPSTRESN
DPSTRESU
DPCOLSRT
1
TOB07
DP
CIG01a
1
LENGTH
Length
DESIGN PARAMETER SPECIFICATION
mm
mm
TARGET
2
TOB07
DP
CIG01a
2
LENGTH
Length
DESIGN PARAMETER SPECIFICATION
mm
mm
MINIMUM
3
TOB07
DP
CIG01a
3
LENGTH
Length
DESIGN PARAMETER SPECIFICATION
mm
mm
MAXIMUM
4
TOB07
DP
CIG01a
4
CIRCUMF
Circumference
DESIGN PARAMETER SPECIFICATION
mm
mm
TARGET
5
TOB07
DP
CIG01a
5
CIRCUMF
Circumference
DESIGN PARAMETER SPECIFICATION
mm
mm
MINIMUM
6
TOB07
DP
CIG01a
6
CIRCUMF
Circumference
DESIGN PARAMETER SPECIFICATION
mm
mm
MAXIMUM
7
TOB07
DP
CIG01a
7
TBFLMASS
Tobacco Filler Mass
DESIGN PARAMETER SPECIFICATION
mg
mg
TARGET
8
TOB07
DP
CIG01a
8
TBFLMASS
Tobacco Filler Mass
DESIGN PARAMETER SPECIFICATION
mg
mg
MINIMUM
9
TOB07
DP
CIG01a
9
TBFLMASS
Tobacco Filler Mass
DESIGN PARAMETER SPECIFICATION
mg
mg
MAXIMUM
10
TOB07
DP
CIG01a
10
MOISTURE
Moisture
DESIGN PARAMETER SPECIFICATION
%
%
TARGET
11
TOB07
DP
CIG01a
11
MOISTURE
Moisture
DESIGN PARAMETER SPECIFICATION
%
%
MINIMUM
12
TOB07
DP
CIG01a
12
MOISTURE
Moisture
DESIGN PARAMETER SPECIFICATION
%
%
MAXIMUM
13
TOB07
DP
CIG01a
13
TOCUTSIZ
Tobacco Cut Size
DESIGN PARAMETER SPECIFICATION
mm or cuts per inch 2
mm or cuts per inch 2
TARGET
14
TOB07
DP
CIG01a
14
TOCUTSIZ
Tobacco Cut Size
DESIGN PARAMETER SPECIFICATION
mm or cuts per inch 2
mm or cuts per inch 2
MINIMUM
15
TOB07
DP
CIG01a
15
TOCUTSIZ
Tobacco Cut Size
DESIGN PARAMETER SPECIFICATION
mm or cuts per inch 2
mm or cuts per inch 2
MAXIMUM
16
TOB07
DP
CIG01a
16
FLTRVENT
Filter Ventilation
DESIGN PARAMETER SPECIFICATION
%
%
TARGET
17
TOB07
DP
CIG01a
17
FLTRVENT
Filter Ventilation
DESIGN PARAMETER SPECIFICATION
%
%
MINIMUM
18
TOB07
DP
CIG01a
18
FLTRVENT
Filter Ventilation
DESIGN PARAMETER SPECIFICATION
%
%
MAXIMUM
19
TOB07
DP
CIG01a
19
TPNPLGTH
Tipping Paper Length
DESIGN PARAMETER SPECIFICATION
mm
mm
TARGET
20
TOB07
DP
CIG01a
20
TPNPLGTH
Tipping Paper Length
DESIGN PARAMETER SPECIFICATION
mm
mm
MINIMUM
21
TOB07
DP
CIG01a
21
TPNPLGTH
Tipping Paper Length
DESIGN PARAMETER SPECIFICATION
mm
mm
MAXIMUM
22
TOB07
DP
CIG01a
22
CIGBPPOR
Cigarette Base Paper Porosity or Permeability
DESIGN PARAMETER SPECIFICATION
CORESTA Unit (Cu)
CORESTA Unit (Cu)
TARGET
23
TOB07
DP
CIG01a
23
CIGBPPOR
Cigarette Base Paper Porosity or Permeability
DESIGN PARAMETER SPECIFICATION
CORESTA Unit (Cu)
CORESTA Unit (Cu)
MINIMUM
24
TOB07
DP
CIG01a
24
CIGBPPOR
Cigarette Base Paper Porosity or Permeability
DESIGN PARAMETER SPECIFICATION
CORESTA Unit (Cu)
CORESTA Unit (Cu)
MAXIMUM
25
TOB07
DP
CIG01a
25
BNDDIF
Cigarette Paper Band Porosity or Permeability or Band Diffusivity
DESIGN PARAMETER SPECIFICATION
CORESTA Unit (Cu) or cm2/s
CORESTA Unit (Cu) or cm2/s
TARGET
26
TOB07
DP
CIG01a
26
BNDDIF
Cigarette Paper Band Porosity or Permeability or Band Diffusivity
DESIGN PARAMETER SPECIFICATION
CORESTA Unit (Cu) or cm2/s
CORESTA Unit (Cu) or cm2/s
MINIMUM
27
TOB07
DP
CIG01a
27
BNDDIF
Cigarette Paper Band Porosity or Permeability or Band Diffusivity
DESIGN PARAMETER SPECIFICATION
CORESTA Unit (Cu) or cm2/s
CORESTA Unit (Cu) or cm2/s
MAXIMUM
28
TOB07
DP
CIG01a
28
CPBNDWID
Cigarette Paper Band Width
DESIGN PARAMETER SPECIFICATION
mm
mm
TARGET
29
TOB07
DP
CIG01a
29
CPBNDWID
Cigarette Paper Band Width
DESIGN PARAMETER SPECIFICATION
mm
mm
MINIMUM
30
TOB07
DP
CIG01a
30
CPBNDWID
Cigarette Paper Band Width
DESIGN PARAMETER SPECIFICATION
mm
mm
MAXIMUM
31
TOB07
DP
CIG01a
31
CPBNDSPC
Cigarette Paper Band Space
DESIGN PARAMETER SPECIFICATION
mm
mm
TARGET
32
TOB07
DP
CIG01a
32
CPBNDSPC
Cigarette Paper Band Space
DESIGN PARAMETER SPECIFICATION
mm
mm
MINIMUM
33
TOB07
DP
CIG01a
33
CPBNDSPC
Cigarette Paper Band Space
DESIGN PARAMETER SPECIFICATION
mm
mm
MAXIMUM
34
TOB07
DP
CIG01a
34
FLTREFF
Filter Efficiency
DESIGN PARAMETER SPECIFICATION
%
%
TARGET
35
TOB07
DP
CIG01a
35
FLTREFF
Filter Efficiency
DESIGN PARAMETER SPECIFICATION
%
%
MINIMUM
36
TOB07
DP
CIG01a
36
FLTREFF
Filter Efficiency
DESIGN PARAMETER SPECIFICATION
%
%
MAXIMUM
37
TOB07
DP
CIG01a
37
DPF
Denier Per Filament
DESIGN PARAMETER SPECIFICATION
/filament
/filament
TARGET
38
TOB07
DP
CIG01a
38
DPF
Denier Per Filament
DESIGN PARAMETER SPECIFICATION
/filament
/filament
MINIMUM
39
TOB07
DP
CIG01a
39
DPF
Denier Per Filament
DESIGN PARAMETER SPECIFICATION
/filament
/filament
MAXIMUM
40
TOB07
DP
CIG01a
40
TDENIER
Total Denier
DESIGN PARAMETER SPECIFICATION
g/9000 m
g/9000 m
TARGET
41
TOB07
DP
CIG01a
41
TDENIER
Total Denier
DESIGN PARAMETER SPECIFICATION
g/9000 m
g/9000 m
MINIMUM
42
TOB07
DP
CIG01a
42
TDENIER
Total Denier
DESIGN PARAMETER SPECIFICATION
g/9000 m
g/9000 m
MAXIMUM
43
TOB07
DP
CIG01a
43
FLTRDEN
Filter Density
DESIGN PARAMETER SPECIFICATION
g/cm3
g/cm3
TARGET
44
TOB07
DP
CIG01a
44
FLTRDEN
Filter Density
DESIGN PARAMETER SPECIFICATION
g/cm3
g/cm3
MINIMUM
45
TOB07
DP
CIG01a
45
FLTRDEN
Filter Density
DESIGN PARAMETER SPECIFICATION
g/cm3
g/cm3
MAXIMUM
46
TOB07
DP
CIG01a
46
FLTRLGTH
Filter Length
DESIGN PARAMETER SPECIFICATION
mm
mm
TARGET
47
TOB07
DP
CIG01a
47
FLTRLGTH
Filter Length
DESIGN PARAMETER SPECIFICATION
mm
mm
MINIMUM
48
TOB07
DP
CIG01a
48
FLTRLGTH
Filter Length
DESIGN PARAMETER SPECIFICATION
mm
mm
MAXIMUM
49
TOB07
DP
CIG01a
49
FLTPRDRP
Filter Pressure Drop
DESIGN PARAMETER SPECIFICATION
mm H2O
mm H2O
TARGET
50
TOB07
DP
CIG01a
50
FLTPRDRP
Filter Pressure Drop
DESIGN PARAMETER SPECIFICATION
mm H2O
mm H2O
MINIMUM
51
TOB07
DP
CIG01a
51
FLTPRDRP
Filter Pressure Drop
DESIGN PARAMETER SPECIFICATION
mm H2O
mm H2O
MAXIMUM
52
TOB07
DP
CIG01a
52
TORODDEN
Tobacco Rod Density
DESIGN PARAMETER SPECIFICATION
g/cm3
g/cm3
TARGET
53
TOB07
DP
CIG01a
53
TORODDEN
Tobacco Rod Density
DESIGN PARAMETER SPECIFICATION
g/cm3
g/cm3
MINIMUM
54
TOB07
DP
CIG01a
54
TORODDEN
Tobacco Rod Density
DESIGN PARAMETER SPECIFICATION
g/cm3
g/cm3
MAXIMUM
55
TOB07
DP
CIG01a
55
Cigarette Paper Length
CIGPLGTH
DESIGN PARAMETER SPECIFICATION
mm
mm
TARGET
56
TOB07
DP
CIG01a
56
Cigarette Paper Length
CIGPLGTH
DESIGN PARAMETER SPECIFICATION
mm
mm
MINIMUM
57
TOB07
DP
CIG01a
57
Cigarette Paper Length
CIGPLGTH
DESIGN PARAMETER SPECIFICATION
mm
mm
MAXIMUM
Dataset Debug Messages
There is a leading, trailing, or non-breaking space in the dataset.
The Tobacco Product Testing (TT) domain is used to represent the actual results of testing for conformance to the tobacco product design parameters shown in DP above.
tt.xpt
tt.xpt
Row
STUDYID
DOMAIN
SPTOBID
TTSEQ
TTTESTCD
TTTEST
TTORRES
TTORRESU
TTSTRESC
TTSTRESN
TTSTRESU
1
TOB07
TT
CIG01a
1
LENGTH
Length
mm
mm
2
TOB07
TT
CIG01a
2
CIRCUMF
Circumference
mm
mm
3
TOB07
TT
CIG01a
3
TBFLMASS
Tobacco Filler Mass
mg
mg
4
TOB07
TT
CIG01a
4
MOISTURE
Moisture
%
%
5
TOB07
TT
CIG01a
5
TOCUTSIZ
Tobacco Cut Size
mm or cuts per inch 2
mm or cuts per inch 2
6
TOB07
TT
CIG01a
6
FLTRVENT
Filter Ventilation
%
%
7
TOB07
TT
CIG01a
7
TPNPLGTH
Tipping Paper Length
mm
mm
8
TOB07
TT
CIG01a
8
CIGBPPOR
Cigarette Base Paper Porosity or Permeability
CORESTA Unit (Cu)
CORESTA Unit (Cu)
9
TOB07
TT
CIG01a
9
BNDDIF
Cigarette Paper Band Porosity or Permeability or Band Diffusivity
The following tables illustrate the controlled terminology for the the --TESTCD and --TEST values that should be submitted for in datasets according to the examples above. for each tobacco product category. (We'll add more language as necessary to make this clearer)
Sponsors should always verify controlled terminology using the published CDISC controlled terminology for the associated codelists below
TOTESTCD
TOTEST
TOSTRESC*
Description
TBPRDCAT
Tobacco Product Category
Waterpipe Tobacco Product
TBPRSCAT
Tobacco Product Subcategory
x;y;z
MANUF
Manufacturer
--
TOSTRESC not subject to controlled terminology for this TEST/TESTCD. Use verbatim name
TRADENAM
Trade Name
--
TOSTRESC not subject to controlled terminology for this TEST/TESTCD. Use verbatim name
*Where TOSTRESC is subject to controlled terminology, use the value (or one of the values) shown in this column.
Since the conformance testing of the design parameters and the design parameters themselves speak to the same concepts, they use the same terminology
DPTESTCD /TTESTCD
DPTEST/TTTEST
Description
TOTESTCD
TOTEST
TOSTRESC*
Description
TBPRDCAT
Tobacco Product Category
Smokeless Tobacco Product
TBPRSCAT
Tobacco Product Subcategory
x;y;z
MANUF
Manufacturer
--
TOSTRESC not subject to controlled terminology for this TEST/TESTCD. Use verbatim name
TRADENAM
Trade Name
--
TOSTRESC not subject to controlled terminology for this TEST/TESTCD. Use verbatim name
*Where TOSTRESC is subject to controlled terminology, use the value (or one of the values) shown in this column.
Since the conformance testing of the design parameters and the design parameters themselves speak to the same concepts, they use the same terminology
DPTESTCD /TTESTCD
DPTEST/TTTEST
Description
This images shows the filtration zone where the ventilation occurs.
Question - is this helpful? Will need permission. This is from the second reference.