SPDEVID = SPTOBID for Sponsor Tobacco Device Identifier
DO/DU = Tobacco Design Parameters (DP)
LB = Tobacco Product Testing (TT)
This is an example for the required tobacco product categorization, property description, and design parameter information in an FDA marketing application for one type of tobacco product Cigarette. There are many more and various types of tobacco products, and their parameters can be found in the in the FDA final rule and guidance documents for tobacco products Premarket Authorization (PMTA) and Substantial Equivalence (SE) Pathways. The applicant submitting for SE and PMTAs should provide test data to include test protocols, quantitative acceptance criteria, data sets, and summary of results as applicable for these parameters.
Tobacco Products (TO) is a study reference dataset that provides a mechanism for uniquely identifying a tobacco product. It is similar to Device Identifiers (DI) in function. The primary purpose of this dataset is to provide a list of the products used in an application or study and to provide identifying information for each product, such as product category type, manufacturer, model (product) name, etc., as applicable. All identifying information is grouped by the Sponsor Tobacco Product Identifier (SPTOBID) (similar to Sponsor Device Identifier (SPDEVID) a consistent variable, that is available for use in other domains where data pertaining to the product may be found.
SPTOBID... ?SPTOBID - should it be SPTOBID for Sponsor Tobacco Product Identifier???
Error rendering macro 'dataset-wrap'
Error occurred rendering template content
The Tobacco Product Design Parameters (DP) is (similar to the Device Properties (DO) domain) represents properties of the tobacco product as used. This is a findings domain and defines important characteristics of a product that the sponsor manufacturer (tobacco researcher) wishes to include in the submission but do not form part of the unique sponsor-defined identification of the product. Each property is identified using controlled terminology and is stored in TTTESTCD/TTTEST.
Rows 1-4:
Show the package type is a hard pack that each contain 20 cigarettes that are 86.0 mm long and 26.0 mm in circumference.
Row 5:
Shows the ventilation flow expressed as a percentage. Ventilation is the aspiration of atmospheric air in an unlit cigarette. (ISO 9512:2019) - 1
Row 6:
Shows the characterizing flavor is menthol for this package of cigarettes.
Row 7:
Shows the heat source is xxx.
dp.xpt
dp.xpt
Row
STUDYID
DOMAIN
SPTOBID
DPSEQ
DPTESTCD
DPTEST
DPCAT
DPSCAT
DPORRES
DPORRESU
DPSTRESC
DPSTRESN
DPSTRESU
DPCOLSRT
1
TOB07
DP
CIG01a
1
LENGTH
Length
DESIGN PARAMETER SPECIFICATION
mm
TARGET
2
TOB07
DP
CIG01a
2
LENGTH
Length
DESIGN PARAMETER SPECIFICATION
mm
MINIMUM
3
TOB07
DP
CIG01a
3
LENGTH
Length
DESIGN PARAMETER SPECIFICATION
mm
MAXIMUM
4
TOB07
DP
CIG01a
4
CIRCUMF
Circumference
DESIGN PARAMETER SPECIFICATION
mm
TARGET
5
TOB07
DP
CIG01a
5
CIRCUMF
Circumference
DESIGN PARAMETER SPECIFICATION
mm
MINIMUM
6
TOB07
DP
CIG01a
6
CIRCUMF
Circumference
DESIGN PARAMETER SPECIFICATION
mm
MAXIMUM
7
TOB07
DP
CIG01a
7
TBFLMASS
Tobacco Filler Mass
DESIGN PARAMETER SPECIFICATION
mg
TARGET
8
TOB07
DP
CIG01a
8
TBFLMASS
Tobacco Filler Mass
DESIGN PARAMETER SPECIFICATION
mg
MINIMUM
9
TOB07
DP
CIG01a
9
TBFLMASS
Tobacco Filler Mass
DESIGN PARAMETER SPECIFICATION
mg
MAXIMUM
10
TOB07
DP
CIG01a
10
MOISTURE
Moisture
DESIGN PARAMETER SPECIFICATION
%
TARGET
11
TOB07
DP
CIG01a
11
MOISTURE
Moisture
DESIGN PARAMETER SPECIFICATION
%
MINIMUM
12
TOB07
DP
CIG01a
12
MOISTURE
Moisture
DESIGN PARAMETER SPECIFICATION
%
MAXIMUM
13
TOB07
DP
CIG01a
13
TOCUTSIZ
Tobacco Cut Size
mm or cuts per inch 2
TARGET
14
TOB07
DP
CIG01a
14
TOCUTSIZ
Tobacco Cut Size
mm or cuts per inch 2
MINIMUM
15
TOB07
DP
CIG01a
15
TOCUTSIZ
Tobacco Cut Size
mm or cuts per inch 2
MAXIMUM
16
TOB07
DP
CIG01a
16
FLTRVENT
Filter Ventilation
%
TARGET
17
TOB07
DP
CIG01a
17
FLTRVENT
Filter Ventilation
%
MINIMUM
18
TOB07
DP
CIG01a
18
FLTRVENT
Filter Ventilation
%
MAXIMUM
19
TOB07
DP
CIG01a
19
TPNPLGTH
Tipping Paper Length
mm
TARGET
20
TOB07
DP
CIG01a
20
TPNPLGTH
Tipping Paper Length
mm
MINIMUM
21
TOB07
DP
CIG01a
21
TPNPLGTH
Tipping Paper Length
mm
MAXIMUM
22
TOB07
DP
CIG01a
22
CIGBPPOR
Cigarette Base Paper Porosity or Permeability
CORESTA Unit (Cu)
TARGET
23
TOB07
DP
CIG01a
23
CIGBPPOR
Cigarette Base Paper Porosity or Permeability
CORESTA Unit (Cu)
MINIMUM
24
TOB07
DP
CIG01a
24
CIGBPPOR
Cigarette Base Paper Porosity or Permeability
CORESTA Unit (Cu)
MAXIMUM
25
TOB07
DP
CIG01a
25
BNDDIF
Cigarette Paper Band Porosity or Permeability or Band Diffusivity
CORESTA Unit (Cu) or cm2/s
TARGET
26
TOB07
DP
CIG01a
26
BNDDIF
Cigarette Paper Band Porosity or Permeability or Band Diffusivity
CORESTA Unit (Cu) or cm2/s
MINIMUM
27
TOB07
DP
CIG01a
27
BNDDIF
Cigarette Paper Band Porosity or Permeability or Band Diffusivity
CORESTA Unit (Cu) or cm2/s
MAXIMUM
28
TOB07
DP
CIG01a
28
CPBNDWID
Cigarette Paper Band Width
mm
TARGET
29
TOB07
DP
CIG01a
29
CPBNDWID
Cigarette Paper Band Width
mm
MINIMUM
30
TOB07
DP
CIG01a
30
CPBNDWID
Cigarette Paper Band Width
mm
MAXIMUM
31
TOB07
DP
CIG01a
31
CPBNDSPC
Cigarette Paper Band Space
mm
TARGET
32
TOB07
DP
CIG01a
32
CPBNDSPC
Cigarette Paper Band Space
mm
MINIMUM
33
TOB07
DP
CIG01a
33
CPBNDSPC
Cigarette Paper Band Space
mm
MAXIMUM
34
TOB07
DP
CIG01a
34
FLTREFF
Filter Efficiency
%
TARGET
35
TOB07
DP
CIG01a
35
FLTREFF
Filter Efficiency
%
MINIMUM
36
TOB07
DP
CIG01a
36
FLTREFF
Filter Efficiency
%
MAXIMUM
37
TOB07
DP
CIG01a
37
DPF
Denier Per Filament
/filament
TARGET
38
TOB07
DP
CIG01a
38
DPF
Denier Per Filament
/filament
MINIMUM
39
TOB07
DP
CIG01a
39
DPF
Denier Per Filament
/filament
MAXIMUM
40
TOB07
DP
CIG01a
40
DENIER
Denier
g/9000 m
TARGET
41
TOB07
DP
CIG01a
41
DENIER
Denier
g/9000 m
MINIMUM
42
TOB07
DP
CIG01a
42
DENIER
Denier
g/9000 m
MAXIMUM
43
TOB07
DP
CIG01a
43
FLTRDEN
Filter Density
g/cm3
TARGET
44
TOB07
DP
CIG01a
44
FLTRDEN
Filter Density
g/cm3
MINIMUM
45
TOB07
DP
CIG01a
45
FLTRDEN
Filter Density
g/cm3
MAXIMUM
46
TOB07
DP
CIG01a
46
FLTRLGTH
Filter Length
mm
TARGET
47
TOB07
DP
CIG01a
47
FLTRLGTH
Filter Length
mm
MINIMUM
48
TOB07
DP
CIG01a
48
FLTRLGTH
Filter Length
mm
MAXIMUM
49
TOB07
DP
CIG01a
49
FLTPRDRP
Filter Pressure Drop
mm H2O
TARGET
50
TOB07
DP
CIG01a
50
FLTPRDRP
Filter Pressure Drop
mm H2O
MINIMUM
51
TOB07
DP
CIG01a
51
FLTPRDRP
Filter Pressure Drop
mm H2O
MAXIMUM
52
TOB07
DP
CIG01a
52
TORODDEN
Tobacco Rod Density
g/cm3
TARGET
53
TOB07
DP
CIG01a
53
TORODDEN
Tobacco Rod Density
g/cm3
MINIMUM
54
TOB07
DP
CIG01a
54
TORODDEN
Tobacco Rod Density
g/cm3
MAXIMUM
55
TOB07
DP
CIG01a
55
Cigarette Paper Length
CIGPLGTH
mm
TARGET
56
TOB07
DP
CIG01a
56
Cigarette Paper Length
CIGPLGTH
mm
MINIMUM
57
TOB07
DP
CIG01a
57
Cigarette Paper Length
CIGPLGTH
mm
MAXIMUM
Dataset Debug Messages
There is a leading, trailing, or non-breaking space in the dataset.