There are many ways to ask if someone has an aneurysm. If the person has prior history of a particular type of aneurysm, say, aortic aneurysm, and the physician suspects that the patient suffers from another one, then specialized imaging instruments that are location-specific can be used. Examples are TRANSESOPHAGEAL ECHOCARDIOGRAPHY or TRANSTHORACIC ECHOCARDIOGRAPHY, they are used to look for abnormalities in the chest and in the abdomen. The original data elements provided to us by DUKE and ACC, from which we created the examples in the CV-imaging TAUG, whether a patient has an aneurysm is asked in a pre-specified fashion? Does the patient have:
Aortic aneurysm? Aortic arch aneurysm?
Abdominal aneurysm? etc.
However, often times when patients complain about discomforts and pain, it is hard to pinpoint the exact location of an aneurysm hence MRI and CT scan are the most frequently used tools to detect aneurysm. In this case, the test location is often broadly defined as chest, abdominal cavity, or the whole-body. The specific location(s) where aneurysms are found are actually locations for the results, not test
Rows 1-2:
Show subject ABC-123 has a single aortic aneurysm from a chest MRI scan.
Rows 3:
Shows the said aneurysm is 7.5cm in length (diameter), which is measured from the aortic arch to the abdominal aorta.
Rows 4-5:
Show subject ABC-456 is found to have aneurysms in two locations from a whole-body MRI Scan: RENAL ARTERY and THORACIC AORTA.
Row Captions Debug Message
Please construct row caption labels as instructed in <ac:link><ri:page ri:content-title="Constructing labels for row captions" ri:space-key="TTD"/></ac:link>.
$titleHtml
cv.xpt
Row
STUDYID
DOMAIN
USUBJID
CVSEQ
CVGRPID
CVTEST
CVORRES
CVORRESU
CVLOC
CVMETHOD
VISITNUM
VISIT
CVDTC
CVRESLOC 1
CVRESLOC 2
CVRLOCTX
1
ABC
CV
ABC-123
1
1
Aneurysm Indicator
Y
CHEST
MRI
1
BASELINE
2020-04-27
2
ABC
CV
ABC-123
2
1
Number of Aneurysms
1
CHEST
MRI
1
BASELINE
2020-04-27
3
ABC
CV
ABC-123
3
1
Aneurysm Length/Diameter
7.5
CM
CHEST
MRI
1
BASELINE
2020-04-27
AORTA
Aortic Arch to Abdominal Aorta
4
ABC
CV
ABC-456
1
2
Aneurysm Indicator
Y
BODY
MRI
1
BASELINE
2020-04-27
5
ABC
CV
ABC-456
2
2
Number of Aneurysms
2
BODY
MRI
1
BASELINE
2020-04-27
RENAL ARTERY
THORACIC AORTA
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
This example shows the minor axis cross-sectional diameter measurements of the left and right ventricle of the heart, at end ventricular diastole.
Row 1:
Shows the cross-sectional diameter of the left ventricle at end ventricular diastole, measured along the minor axis and specifically at the location of the high papillary muscle. The further anatomical details at which the measurement is set and performed is represented by the CVLOCTX NSV.
Row 2:
Shows the cross-sectional diameter of the right ventricle at end ventricular diastole, measured along the minor axis and specifically at just below the tricuspid valve. The further anatomical details at which the measurement is set and performed is represented by the CVLOCTX NSV.