titleTobacco domains

DI = TO for Tobacco Product Identifier

SPDEVID = SPTOBID for Sponsor Tobacco Device Identifier

DO/DU = Tobacco Design Parameters (DP)

LB = Tobacco Product Testing (TT)

This is an example for the required tobacco product categorization, property description, and design parameter information in an FDA marketing application for one type of tobacco product Cigarette. There are many more and various types of tobacco products, and their parameters can be found in the in the FDA final rule and guidance documents for tobacco products Premarket Authorization (PMTA) and Substantial Equivalence (SE) Pathways. The applicant submitting for SE and PMTAs should provide test data to include test protocols, quantitative acceptance criteria, data sets, and summary of results as applicable for these parameters.

Tobacco Products (TO) is a study reference dataset that provides a mechanism for uniquely identifying a tobacco product. It is similar to Device Identifiers (DI) in function. The primary purpose of this dataset is to provide a list of the products used in an application or study and to provide identifying information for each product, such as product category type, manufacturer, model (product) name, etc., as applicable. All identifying information is grouped by the Sponsor Tobacco Product Identifier (SPTOBID) (similar to Sponsor Device Identifier (SPDEVID) a consistent variable, that is available for use in other domains where data pertaining to the product may be found.

 SPTOBID... ?SPTOBID - should it be SPTOBID for Sponsor Tobacco Product Identifier???illustrates the representation of a cigarette product's identifiers and descriptors using the TO domain. Note that this example uses TOSCAT (Subcategory of Tobacco Prod ID Element, a permissible variable) to emphasize and differentiate the 2 distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors. 

Option 1 of Steve H's suggestion of combining our  previous product identifiers and product descriptors into a single dataset:Show the tobacco product is a filtered, combusted type of cigarette.
Dataset wrap
Nameto
Rowcaps
Rows 1-4:Show the records for a tobacco product given SPTOBID of CIG01a.
Rows 3-4:
Dataset2
RowSTUDYIDDOMAINSPTOBIDTOSEQTOPARMCDTOPARMTOCATTOSCATTOVALTOVALU
1TOB07TOCIG01a

1

TBPRDCATTobacco Product CategoryNEW PRODUCTPRODUCT IDENTIFIERCigarettesCigarette
2TOB07TOCIG01a2TBPRSCATTobacco Product SubcategoryNEW PRODUCTPRODUCT IDENTIFIERFiltered, Combusted
3TOB07TOCIG01a3MANUFManufacturerNEW PRODUCTPRODUCT IDENTIFIERJoes Cigs USA
4TOB07TOCIG01a4TRADENAMTrade NameNEW PRODUCTPRODUCT IDENTIFIERTreetop Menthol King Size
5TOB07TOCIG01a5PACKTYPPackage TypeNEW PRODUCTPRODUCT DESCRIPTORHARD PACK
6TOB07TOCIG01a6PRDQUANProduct QuantityNEW PRODUCTPRODUCT DESCRIPTOR20CIGARETTE
7TOB07TOCIG01a7LENGTHLengthNEW PRODUCTPRODUCT DESCRIPTOR86.0mm
8TOB07TOCIG01a8CIRCUMFCircumferenceNEW PRODUCTPRODUCT DESCRIPTOR26.0mm
9TOB07TOCIG01a9VENTLTNVENTLTOTTotal VentilationNEW PRODUCTPRODUCT DESCRIPTOR10.0%
10TOB07TOCIG01a10CHARFLAVCharacterizing FlavorNEW PRODUCTPRODUCT DESCRIPTORMENTHOL
Option 2 of Steve H's suggestion of combining our  previous product identifiers and product descriptors into a single dataset:

The manufacturing parameter specifications of the cigarette tobacco product as intended for use are represented in the PD domain  The following example shows the target, minimum, and maximum values associated with each of 23 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.

Note the use of the variable IGDCMPID (Ingredient or Component Identifier) in rows 5-6. This tobacco product had 2 tobacco ingredients with 2 different tobacco cut sizes. IGDCMPID identifies to which tobacco ingredient the cut size applies. IGDCMPID originates in the IT (Tobacco Ingredients) and IN (Non-Tobacco Ingredients) domains. See Section 3.1.3.1, Ingredients and Additives, for more information.

Dataset wrap
Namepd
Dataset2
RowSTUDYIDDOMAINSPTOBIDTOSEQIGDCMPIDTOTESTCDPDSEQTOTESTPDPARMCDTOCATPDPARMTOSCATPDVALTRGTOORRESPDVALMINTOORRESUTOSTRESCTOSTRESNTOSTRESUPDVALMAXPDVALUTOCOLSRT
1

TOB07

TOPDCIG01a


1

LENGTHLengthTBPRDCATTobacco Product CategoryCigarette

84

83.5

84.5

mm

Cigarette

2TOB07TOPDCIG01a
2TBPRSCATTobacco Product SubcategoryFiltered, CombustedCIRCUMFCircumference24.824.625mmFiltered, Combusted
3TOB07TOPDCIG01a
3MANUFManufacturerJoes Cigs USATBFLMASSTobacco Filler Mass783753814mgJoes Cigs USA
4TOB07TOPDCIG01a
4MOISTUREMoistureTRADENAM13Trade NameTreetop Methol King Size1214%Treetop Methol King Size
5TOB07TOPDCIG01a

Burley tobacco

5PACKTYPPackage TypeHARD PACKTOCUTSIZTobacco Cut Size

22

20

24

cuts/in

HARD PACK

6TOB07TOPDCIG01a

Reconstituted tobacco

6PRDQUANProduct Quantity20CIGARETTE2020TOCUTSIZTobacco Cut Size

27

25

29

mm

CIGARETTE

7TOB07TOPDCIG01a


7LENGTHVENTLFLTLength86.0mm86.086.0Filter Ventilation

30

23

37

%

mm

8TOB07TOPDCIG01a
8CIRCUMFTPNPLGTHCircumference26.0mm26.0Tipping Paper Length31303226.0mm
9TOB07TOPDCIG01a
9VENTLTNVentilation10.0%10.010.0CBPPOR

Cigarette Base Paper Porosity

50

45

55Cu%
10TOB07TOPDCIG01a


10CHARFLAVCharacterizing FlavorMENTHOLCBPPERMCigarette Base Paper Permeability

50

45

55

Cu

MENTHOL

11TOB07TOPDCIG01a
11HTSOURCEHeat Sourcexxxxxx

OPtion 2:

...

Nameto

...

CPBPORCigarette Paper Band Porosity100.213Cu
12TOB07PDCIG01a
12CPBPERMCigarette Paper Band Permeability100.213Cu
13TOB07PDCIG01a
13

CPBDIFF

Cigarette Paper Band Diffusivity0.050.0010.100cm2/s
14TOB07PDCIG01a


14CPBWIDCigarette Paper Band Width

7

6.7

7.3

mm

15TOB07PDCIG01a


15CPBSPCCigarette Paper Band Space20

19.8

20.2

mm

16TOB07PDCIG01a


16FLTREFFFilter Efficiency

30

25

35

%

17TOB07PDCIG01a


17DPFDenier Per Filament43.64.4


18TOB07PDCIG01a


18TDENIERTotal Denier

30000

29100

30900

g/9000m

19TOB07PDCIG01a
19FLTRDENFilter Density0.12340.1050.1419g/cm3
20TOB07PDCIG01a
20FLTRLGTHFilter Length2524.525.5mm
21TOB07PDCIG01a
21FLTPRDRPFilter Pressure Drop605169mm H2O
22TOB07PDCIG01a
22TORODDENTobacco Rod Density0.26780.24370.2919g/cm3
23TOB07PDCIG01a
23CIGPLGTHCigarette Paper Length535254mm

Finally, the PT domain is used to represent the actual results of testing the manufactured cigarette product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a Required variable and is set to "DESIGN PARAMETER TESTING" for all records here. As described in the PD example, IGDCMPID is also used here to differentiate 2 records of the same test performed on each of 2 different types of tobacco that are ingredients of the tobacco product. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only 1 replicate per parameter is shown. Note that PTREPNUM (repetition number) = 1 for all rows.

Dataset wrap
Namept

...

1

...

The Tobacco Product Design Parameters (DP)  is (similar to the Device Properties (DO) domain) represents properties of the tobacco product as used. This is a findings domain and defines important characteristics of a product that the sponsor manufacturer (tobacco researcher) wishes to include in the submission but do not form part of the unique sponsor-defined identification of the product. Each property is identified using controlled terminology and is stored in TTTESTCD/TTTEST.

Shows the heat source is xxx. 
Dataset wrap
Namedp
Rowcaps
Rows 1-4:Show the package type is a hard pack that each contain 20 cigarettes that are 86.0 mm long and 26.0 mm in circumference.
Row 5:Shows the ventilation flow expressed as a percentage. Ventilation is the aspiration of atmospheric air in an unlit cigarette. (ISO 9512:2019) - 1
Row 6:Shows the characterizing flavor is menthol for this package of cigarettes.
Row 7:
DP
Dataset2
RowSTUDYIDDOMAINSPTOBID
DPSEQ
IGDCMPIDPTSEQ
DPTESTCD
PTTESTCD
DPTEST
PTTEST
DPCAT
PTCAT
DPSCAT
PTORRES
DPORRES
PTORRESU
DPORRESU
PTSTRESC
DPSTRESC
PTSTRESN
DPSTRESN
PTSTRESU
DPSTRESU
PTMETHOD
DPCOLSRT
PTREPNUM
1TOB07
DP
PTCIG01a

1

TBPRDCATTobacco Product CategoryCigaretteCigarette2TOB07

CIG01a2TBPRSCATTobacco Product SubcategoryFiltered, CombustedFiltered, Combusted3TOB07DPCIG01a3MANUFManufacturerJoes Cigs USAJoes Cigs USA4TOB07DPCIG01a4TRADENAMTrade NameTreetop Methol King SizeTreetop Methol King Size5TOB07DPCIG01a5PACKTYPPackage TypeHARD PACKHARD PACK6TOB07DPCIG01a6PRDQUANProduct Quantity20CIGARETTE2020CIGARETTE7TOB07DPCIG01a7LENGTHLength86.0mm86.086.0mm8TOB07DPCIG01a8CIRCUMFCircumference26.0mm26.026.0mm9TOB07DPCIG01a9VENTLTNVentilation10.0%10.010.0%10TOB07DPCIG01a10CHARFLAVCharacterizing FlavorMENTHOLMENTHOL11TOB07DPCIG01a11HTSOURCEHeat Sourcexxxxxx12

TOB07

DPCIG01a12LENGTHLengthDESIGN PARAMETER SPECIFICATIONmmTARGET13TOB07DPCIG01a13LENGTHLengthDESIGN PARAMETER SPECIFICATIONmmMINIMUM14TOB07DPCIG01a14LENGTHLengthDESIGN PARAMETER SPECIFICATIONmmMAXIMUM15TOB07DPCIG01a15Cigarette circumference or diameter 2DESIGN PARAMETER SPECIFICATIONmmTARGET16TOB07DPCIG01a16Cigarette circumference or diameter 2DESIGN PARAMETER SPECIFICATIONmmMINIMUM17TOB07DPCIG01a17Cigarette circumference or diameter 2DESIGN PARAMETER SPECIFICATIONmmMAXIMUM18TOB07DPCIG01a18Tobacco Filler massDESIGN PARAMETER SPECIFICATIONmgTARGET19TOB07DPCIG01a19Tobacco Filler massDESIGN PARAMETER SPECIFICATIONmgMINIMUM20TOB07DPCIG01a20Tobacco Filler massDESIGN PARAMETER SPECIFICATIONmgMAXIMUM21TOB07DPCIG01a21Tobacco moisture or Oven VolatilesDESIGN PARAMETER SPECIFICATION%TARGET22TOB07DPCIG01a22Tobacco moisture or Oven VolatilesDESIGN PARAMETER SPECIFICATION%MINIMUM23TOB07DPCIG01a23Tobacco moisture or Oven VolatilesDESIGN PARAMETER SPECIFICATION%MAXIMUM24TOB07DPCIG01a24Tobacco cut sizemm or cuts per inch 2TARGET25TOB07DPCIG01a25Tobacco cut sizemm or cuts per inch 2MINIMUM26TOB07DPCIG01a26Tobacco cut sizemm or cuts per inch 2MAXIMUM27TOB07DPCIG01a27Filter Ventilation%TARGET28TOB07DPCIG01a28Filter Ventilation%MINIMUM29TOB07DPCIG01a29Filter Ventilation%MAXIMUM30TOB07DPCIG01a30Tipping Paper LengthmmTARGET31TOB07DPCIG01a31Tipping Paper LengthmmMINIMUM32TOB07DPCIG01a32Tipping Paper LengthmmMAXIMUM33TOB07DPCIG01a33Cigarette base paper Porosity or PermeabilityCORESTA Unit (Cu)TARGET34TOB07DPCIG01a34Cigarette base paper Porosity or PermeabilityCORESTA Unit (Cu)MINIMUM35TOB07DPCIG01a35Cigarette base paper Porosity or PermeabilityCORESTA Unit (Cu)MAXIMUM36TOB07DPCIG01a36Cigarette Paper band porosity or permeability or band diffusivityCORESTA Unit (Cu) or cm2/sTARGET37TOB07DPCIG01a37Cigarette Paper band porosity or permeability or band diffusivityCORESTA Unit (Cu) or cm2/sMINIMUM38TOB07DPCIG01a38Cigarette Paper band porosity or permeability or band diffusivityCORESTA Unit (Cu) or cm2/sMAXIMUM39TOB07DPCIG01a39Cigarette Paper band widthmmTARGET40TOB07DPCIG01a40Cigarette Paper band widthmmMINIMUM41TOB07DPCIG01a41Cigarette Paper band widthmmMAXIMUM42TOB07DPCIG01a42Cigarette Paper band spacemmTARGET43TOB07DPCIG01a43Cigarette Paper band spacemmMINIMUM44TOB07DPCIG01a44Cigarette Paper band spacemmMAXIMUM45TOB07DPCIG01a45Filter efficiency 1%TARGET46TOB07DPCIG01a46Filter efficiency 1%MINIMUM47TOB07DPCIG01a47Filter efficiency 1%MAXIMUM48TOB07DPCIG01a48Denier per FilamentDPFTARGET49TOB07DPCIG01a49Denier per FilamentDPFMINIMUM50TOB07DPCIG01a50Denier per FilamentDPFMAXIMUM51TOB07DPCIG01a51Total Denierg/9000 mTARGET52TOB07DPCIG01a52Total Denierg/9000 mMINIMUM53TOB07DPCIG01a53Total Denierg/9000 mMAXIMUM54TOB07DPCIG01a54Filter Densityg/cm3TARGET55TOB07DPCIG01a55Filter Densityg/cm3MINIMUM56TOB07DPCIG01a56Filter Densityg/cm3MAXIMUM57TOB07DPCIG01a57Filter LengthmmTARGET58TOB07DPCIG01a58Filter LengthmmMINIMUM59TOB07DPCIG01a59Filter LengthmmMAXIMUM60TOB07DPCIG01a60Filter Pressure Dropmm H2OTARGET61TOB07DPCIG01a61Filter Pressure Dropmm H2OMINIMUM62TOB07DPCIG01a62Filter Pressure Dropmm H2OMAXIMUM63TOB07DPCIG01a63Tobacco Rod Densityg/cm3TARGET64TOB07DPCIG01a64Tobacco Rod Densityg/cm3MINIMUM65TOB07DPCIG01a65Tobacco Rod Densityg/cm3MAXIMUM66TOB07DPCIG01a66Cigarette Paper LengthmmTARGET67TOB07DPCIG01a67Cigarette Paper LengthmmMINIMUM68TOB07DPCIG01a68Cigarette Paper LengthmmMAXIMUM
Dataset wrap
Namett
RowcapsRows 1-4:Row 5:SRow 6:Row 7: Dataset2RowSTUDYIDDOMAINSPTOBIDTTSEQTTREFIDTTGRPIDTTTESTCDTTTESTTTCATTTORRESTTORRESUTTSTRESCTTSTRESNTTSTRESUTTCOLSRT1TOB07TTCIG01a1Tobacco Filler massmg

mg

2TOB07TTCIG01a2Tobacco moisture or Oven Volatiles%%3TOB07TTCIG01a3Tobacco cut sizemm or cuts per inch 2mm or cuts per inch 24TOB07TTCIG01a4Tobacco Rod densityg/cm3g/cm35TOB07TTCIG01a5Filter Ventilation%%6TOB07TTCIG01a6Cigarette base paper Porosity or PermeabilityCORESTA Unit (Cu)CORESTA Unit (Cu)7TOB07TTCIG01a7Cigarette Paper band porosity or permeability or band diffusivityCORESTA Unit (Cu) or cm2/sCORESTA Unit (Cu) or cm2/s8TOB07TTCIG01a8Filter efficiency 1%%9TOB07TTCIG01a9Denier per FilamentDPFDPF10TOB07TTCIG01a10Total Denierg/9000 mg/9000 m11TOB07TTCIG01a11Filter Densityg/cm3g/cm312TOB07TTCIG01a12Filter Pressure Dropmm H2Omm H2O

This images shows the filtration zone where the ventilation occurs.

Image Removed

Question - is this helpful?  Will need permission.  This is from the second reference.

References:

LENGTHLengthDESIGN PARAMETER TESTING

83.9

mm

83.9

83.9

mm
1
2TOB07PTCIG01a
2CIRCUMFCircumferenceDESIGN PARAMETER TESTING24.9mm24.924.9mm
1
3TOB07PTCIG01a
3TBFLMASSTobacco Filler MassDESIGN PARAMETER TESTING779mg779779mg
1
4TOB07PTCIG01a
4MOISTUREMoistureDESIGN PARAMETER TESTING13.1%13.113.1%
1
5TOB07PTCIG01a

Burley tobacco

5TOCUTSIZTobacco Cut SizeDESIGN PARAMETER TESTING22cuts/in2222cuts/in
1
6TOB07PTCIG01a

Reconstituted tobacco

6TOCUTSIZTobacco Cut SizeDESIGN PARAMETER TESTING27mm2727mm
1
7TOB07PTCIG01a
7VENTLFLTFilter VentilationDESIGN PARAMETER TESTING35%3535%
1
8TOB07PTCIG01a
8TPNPLGTHTipping Paper LengthDESIGN PARAMETER TESTING30mm3030mm
1
9TOB07PTCIG01a
9CBPPORCigarette Base Paper PorosityDESIGN PARAMETER TESTING48Cu4848Cu
1
10TOB07PTCIG01a
10CBPPERMCigarette Base Paper PermeabilityDESIGN PARAMETER TESTING50Cu5050Cu
1
11TOB07PTCIG01a
11CPBPORCigarette Paper Band PorosityDESIGN PARAMETER TESTING9.8Cu9.89.8Cu
1
12TOB07PTCIG01a
12CPBPERMCigarette Paper Band PermeabilityDESIGN PARAMETER TESTING10Cu1010Cu
1
13TOB07PTCIG01a
13CPBDIFFCigarette Paper Band DiffusivityDESIGN PARAMETER TESTING0.06cm2/s0.060.06cm2/s
1
14TOB07PTCIG01a
14CPBWIDCigarette Paper Band WidthDESIGN PARAMETER TESTING7.1mm7.17.1mm
1
15TOB07PTCIG01a
15CPBSPCCigarette Paper Band SpaceDESIGN PARAMETER TESTING19.9mm19.919.9mm
1
16TOB07PTCIG01a
16FLTREFFFilter EfficiencyDESIGN PARAMETER TESTING28%2828%
1
17TOB07PTCIG01a
17DPFDenier Per FilamentDESIGN PARAMETER TESTING4.1
4.14.1

1
18TOB07PTCIG01a
18TDENIERTotal DenierDESIGN PARAMETER TESTING29900g/9000m2990029900g/9000m
1
19TOB07PTCIG01a
19FLTRDENFilter DensityDESIGN PARAMETER TESTING0.1112g/cm30.11120.1112g/cm3
1
20TOB07PTCIG01a
20FLTRLGTHFilter LengthDESIGN PARAMETER TESTING25mm2525mm
1
21TOB07PTCIG01a
21FLTPRDRPFilter Pressure DropDESIGN PARAMETER TESTING62mm H2O6262mm H2O
1
22TOB07PTCIG01a
22TORODDENTobacco Rod DensityDESIGN PARAMETER TESTING0.2701g/cm30.27010.2701g/cm3
1
23TOB07PTCIG01a
23CIGPLGTHCigarette Paper LengthDESIGN PARAMETER TESTING53mm5353mm
1

References:

  1. International Organization for Standardization. ISO 9512:2019(en) - Cigarettes — Determination of ventilation — Definitions and measurement principles. ISO; June 2019. Accessed October 15, 2023. https://www.iso.org/obp/ui/#iso:std:iso:9512:ed-3:v1:en
  2. Song M-A, Benowitz NL, Berman M, et al. Cigarette filter ventilation and its relationship to increasing rates of lung adenocarcinoma. J Natl Cancer Inst. 2017;109(12):djx075. https://wwwdoi.ncbi.nlm.nih.gov/pmc/articles/PMC6059254/org/10.1093/jnci/djx075