This example illustrates the representation of a cigarette product's identifiers and descriptors using the TO domain. Note that this example uses TOSCAT (Subcategory of Tobacco Prod ID Element, a permissible variable) to emphasize and differentiate the 2 distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors.
Row | STUDYID | DOMAIN | SPTOBID | TOSEQ | TOPARMCD | TOPARM | TOCAT | TOSCAT | TOVAL | TOVALU |
---|
1 | TOB07 | TO | CIG01a | | TBPRDCAT | Tobacco Product Category | NEW PRODUCT | PRODUCT IDENTIFIER | Cigarettes |
| 2 | TOB07 | TO | CIG01a | 2 | TBPRSCAT | Tobacco Product Subcategory | NEW PRODUCT | PRODUCT IDENTIFIER | Filtered |
| 3 | TOB07 | TO | CIG01a | 3 | MANUF | Manufacturer | NEW PRODUCT | PRODUCT IDENTIFIER | Joes Cigs USA |
| 4 | TOB07 | TO | CIG01a | 4 | TRADENAM | Trade Name | NEW PRODUCT | PRODUCT IDENTIFIER | Treetop Menthol King Size |
| 5 | TOB07 | TO | CIG01a | 5 | PACKTYP | Package Type | NEW PRODUCT | PRODUCT DESCRIPTOR | HARD PACK |
| 6 | TOB07 | TO | CIG01a | 6 | PRDQUAN | Product Quantity | NEW PRODUCT | PRODUCT DESCRIPTOR | 20 | CIGARETTE | 7 | TOB07 | TO | CIG01a | 7 | LENGTH | Length | NEW PRODUCT | PRODUCT DESCRIPTOR | 86.0 | mm | 8 | TOB07 | TO | CIG01a | 8 | CIRCUMF | Circumference | NEW PRODUCT | PRODUCT DESCRIPTOR | 26.0 | mm | 9 | TOB07 | TO | CIG01a | 9 | VENTLTOT | Total Ventilation | NEW PRODUCT | PRODUCT DESCRIPTOR | 10.0 | % | 10 | TOB07 | TO | CIG01a | 10 | CHARFLAV | Characterizing Flavor | NEW PRODUCT | PRODUCT DESCRIPTOR | MENTHOL |
|
|
|
The manufacturing parameter specifications of the cigarette tobacco product as intended for use are represented in the PD domain The following example shows the target, minimum, and maximum values associated with each of 23 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.
Note the use of the variable IGDCMPID (Ingredient or Component Identifier) in rows 5-6. This tobacco product had 2 tobacco ingredients with 2 different tobacco cut sizes. IGDCMPID identifies to which tobacco ingredient the cut size applies. IGDCMPID originates in the IT (Tobacco Ingredients) and IN (Non-Tobacco Ingredients) domains. See Section 3.1.3.1, Ingredients and Additives, for more information.
Row | STUDYID | DOMAIN | SPTOBID | IGDCMPID | PDSEQ | PDPARMCD | PDPARM | PDVALTRG | PDVALMIN | PDVALMAX | PDVALU |
---|
1 | | PD | CIG01a | | | LENGTH | Length | | | 84.5 | | 2 | TOB07 | PD | CIG01a |
| 2 | CIRCUMF | Circumference | 24.8 | 24.6 | 25 | mm | 3 | TOB07 | PD | CIG01a |
| 3 | TBFLMASS | Tobacco Filler Mass | 783 | 753 | 814 | mg | 4 | TOB07 | PD | CIG01a |
| 4 | MOISTURE | Moisture | 13 | 12 | 14 | % | 5 | TOB07 | PD | CIG01a | | 5 | TOCUTSIZ | Tobacco Cut Size | | | 24 | | 6 | TOB07 | PD | CIG01a | | 6 | TOCUTSIZ | Tobacco Cut Size | | | 29 | | 7 | TOB07 | PD | CIG01a | | 7 | VENTLFLT | Filter Ventilation | | | 37 | | 8 | TOB07 | PD | CIG01a |
| 8 | TPNPLGTH | Tipping Paper Length | 31 | 30 | 32 | mm | 9 | TOB07 | PD | CIG01a |
| 9 | CBPPOR | Cigarette Base Paper Porosity | | | 55 | Cu | 10 | TOB07 | PD | CIG01a | | 10 | CBPPERM | Cigarette Base Paper Permeability | | | 55 | | 11 | TOB07 | PD | CIG01a |
| 11 | CPBPOR | Cigarette Paper Band Porosity | 10 | 0.2 | 13 | Cu | 12 | TOB07 | PD | CIG01a |
| 12 | CPBPERM | Cigarette Paper Band Permeability | 10 | 0.2 | 13 | Cu | 13 | TOB07 | PD | CIG01a |
| 13 | | Cigarette Paper Band Diffusivity | 0.05 | 0.001 | 0.100 | cm2/s | 14 | TOB07 | PD | CIG01a | | 14 | CPBWID | Cigarette Paper Band Width | | | 7.3 | | 15 | TOB07 | PD | CIG01a | | 15 | CPBSPC | Cigarette Paper Band Space | 20 | | 20.2 | | 16 | TOB07 | PD | CIG01a | | 16 | FLTREFF | Filter Efficiency | | | 35 | | 17 | TOB07 | PD | CIG01a | | 17 | DPF | Denier Per Filament | 4 | 3.6 | 4.4 | | 18 | TOB07 | PD | CIG01a | | 18 | TDENIER | Total Denier | | | 30900 | | 19 | TOB07 | PD | CIG01a |
| 19 | FLTRDEN | Filter Density | 0.1234 | 0.105 | 0.1419 | g/cm3 | 20 | TOB07 | PD | CIG01a |
| 20 | FLTRLGTH | Filter Length | 25 | 24.5 | 25.5 | mm | 21 | TOB07 | PD | CIG01a |
| 21 | FLTPRDRP | Filter Pressure Drop | 60 | 51 | 69 | mm H2O | 22 | TOB07 | PD | CIG01a |
| 22 | TORODDEN | Tobacco Rod Density | 0.2678 | 0.2437 | 0.2919 | g/cm3 | 23 | TOB07 | PD | CIG01a |
| 23 | CIGPLGTH | Cigarette Paper Length | 53 | 52 | 54 | mm |
|
|
Finally, the PT domain is used to represent the actual results of testing the manufactured cigarette product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a Required variable and is set to "DESIGN PARAMETER TESTING" for all records here. As described in the PD example, IGDCMPID is also used here to differentiate 2 records of the same test performed on each of 2 different types of tobacco that are ingredients of the tobacco product. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only 1 replicate per parameter is shown. Note that PTREPNUM (repetition number) = 1 for all rows.
Row | STUDYID | DOMAIN | SPTOBID | IGDCMPID | PTSEQ | PTTESTCD | PTTEST | PTCAT | PTORRES | PTORRESU | PTSTRESC | PTSTRESN | PTSTRESU | PTMETHOD | PTREPNUM |
---|
1 | TOB07 | PT | CIG01a |
| | LENGTH | Length | DESIGN PARAMETER TESTING | | mm | | | mm |
| 1 | 2 | TOB07 | PT | CIG01a |
| 2 | CIRCUMF | Circumference | DESIGN PARAMETER TESTING | 24.9 | mm | 24.9 | 24.9 | mm |
| 1 | 3 | TOB07 | PT | CIG01a |
| 3 | TBFLMASS | Tobacco Filler Mass | DESIGN PARAMETER TESTING | 779 | mg | 779 | 779 | mg |
| 1 | 4 | TOB07 | PT | CIG01a |
| 4 | MOISTURE | Moisture | DESIGN PARAMETER TESTING | 13.1 | % | 13.1 | 13.1 | % |
| 1 | 5 | TOB07 | PT | CIG01a | | 5 | TOCUTSIZ | Tobacco Cut Size | DESIGN PARAMETER TESTING | 22 | cuts/in | 22 | 22 | cuts/in |
| 1 | 6 | TOB07 | PT | CIG01a | | 6 | TOCUTSIZ | Tobacco Cut Size | DESIGN PARAMETER TESTING | 27 | mm | 27 | 27 | mm |
| 1 | 7 | TOB07 | PT | CIG01a |
| 7 | VENTLFLT | Filter Ventilation | DESIGN PARAMETER TESTING | 35 | % | 35 | 35 | % |
| 1 | 8 | TOB07 | PT | CIG01a |
| 8 | TPNPLGTH | Tipping Paper Length | DESIGN PARAMETER TESTING | 30 | mm | 30 | 30 | mm |
| 1 | 9 | TOB07 | PT | CIG01a |
| 9 | CBPPOR | Cigarette Base Paper Porosity | DESIGN PARAMETER TESTING | 48 | Cu | 48 | 48 | Cu |
| 1 | 10 | TOB07 | PT | CIG01a |
| 10 | CBPPERM | Cigarette Base Paper Permeability | DESIGN PARAMETER TESTING | 50 | Cu | 50 | 50 | Cu |
| 1 | 11 | TOB07 | PT | CIG01a |
| 11 | CPBPOR | Cigarette Paper Band Porosity | DESIGN PARAMETER TESTING | 9.8 | Cu | 9.8 | 9.8 | Cu |
| 1 | 12 | TOB07 | PT | CIG01a |
| 12 | CPBPERM | Cigarette Paper Band Permeability | DESIGN PARAMETER TESTING | 10 | Cu | 10 | 10 | Cu |
| 1 | 13 | TOB07 | PT | CIG01a |
| 13 | CPBDIFF | Cigarette Paper Band Diffusivity | DESIGN PARAMETER TESTING | 0.06 | cm2/s | 0.06 | 0.06 | cm2/s |
| 1 | 14 | TOB07 | PT | CIG01a |
| 14 | CPBWID | Cigarette Paper Band Width | DESIGN PARAMETER TESTING | 7.1 | mm | 7.1 | 7.1 | mm |
| 1 | 15 | TOB07 | PT | CIG01a |
| 15 | CPBSPC | Cigarette Paper Band Space | DESIGN PARAMETER TESTING | 19.9 | mm | 19.9 | 19.9 | mm |
| 1 | 16 | TOB07 | PT | CIG01a |
| 16 | FLTREFF | Filter Efficiency | DESIGN PARAMETER TESTING | 28 | % | 28 | 28 | % |
| 1 | 17 | TOB07 | PT | CIG01a |
| 17 | DPF | Denier Per Filament | DESIGN PARAMETER TESTING | 4.1 |
| 4.1 | 4.1 |
|
| 1 | 18 | TOB07 | PT | CIG01a |
| 18 | TDENIER | Total Denier | DESIGN PARAMETER TESTING | 29900 | g/9000m | 29900 | 29900 | g/9000m |
| 1 | 19 | TOB07 | PT | CIG01a |
| 19 | FLTRDEN | Filter Density | DESIGN PARAMETER TESTING | 0.1112 | g/cm3 | 0.1112 | 0.1112 | g/cm3 |
| 1 | 20 | TOB07 | PT | CIG01a |
| 20 | FLTRLGTH | Filter Length | DESIGN PARAMETER TESTING | 25 | mm | 25 | 25 | mm |
| 1 | 21 | TOB07 | PT | CIG01a |
| 21 | FLTPRDRP | Filter Pressure Drop | DESIGN PARAMETER TESTING | 62 | mm H2O | 62 | 62 | mm H2O |
| 1 | 22 | TOB07 | PT | CIG01a |
| 22 | TORODDEN | Tobacco Rod Density | DESIGN PARAMETER TESTING | 0.2701 | g/cm3 | 0.2701 | 0.2701 | g/cm3 |
| 1 | 23 | TOB07 | PT | CIG01a |
| 23 | CIGPLGTH | Cigarette Paper Length | DESIGN PARAMETER TESTING | 53 | mm | 53 | 53 | mm |
| 1 |
|
|
References:
- International Organization for Standardization. ISO 9512:2019(en) - Cigarettes — Determination of ventilation — Definitions and measurement principles. ISO; June 2019. Accessed October 15, 2023. https://www.iso.org/obp/ui/#iso:std:iso:9512:ed-3:v1:en
- Song M-A, Benowitz NL, Berman M, et al. Cigarette filter ventilation and its relationship to increasing rates of lung adenocarcinoma. J Natl Cancer Inst. 2017;109(12):djx075. https://doi.org/10.1093/jnci/djx075