The following This example illustrates the representation of a cigarette product's identifiers and descriptors using the TO domain. Note that this example makes use of uses TOSCAT (Subcategory of Tobacco Prod ID Element, a permissible variable) to emphasize and differentiate the two 2 distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors.
Dataset wrap |
---|
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | SPTOBID | TOSEQ | TOPARMCD | TOPARM | TOCAT | TOSCAT | TOVAL | TOVALU |
---|
1 | TOB07 | TO | CIG01a | | TBPRDCAT | Tobacco Product Category | NEW PRODUCT | PRODUCT IDENTIFIER | CigaretteCigarettes |
| 2 | TOB07 | TO | CIG01a | 2 | TBPRSCAT | Tobacco Product Subcategory | NEW PRODUCT | PRODUCT IDENTIFIER | Filtered | , Combusted |
| 3 | TOB07 | TO | CIG01a | 3 | MANUF | Manufacturer | NEW PRODUCT | PRODUCT IDENTIFIER | Joes Cigs USA |
| 4 | TOB07 | TO | CIG01a | 4 | TRADENAM | Trade Name | NEW PRODUCT | PRODUCT IDENTIFIER | Treetop Menthol King Size |
| 5 | TOB07 | TO | CIG01a | 5 | PACKTYP | Package Type | NEW PRODUCT | PRODUCT DESCRIPTOR | HARD PACK |
| 6 | TOB07 | TO | CIG01a | 6 | PRDQUAN | Product Quantity | NEW PRODUCT | PRODUCT DESCRIPTOR | 20 | CIGARETTE | 7 | TOB07 | TO | CIG01a | 7 | LENGTH | Length | NEW PRODUCT | PRODUCT DESCRIPTOR | 86.0 | mm | 8 | TOB07 | TO | CIG01a | 8 | CIRCUMF | Circumference | NEW PRODUCT | PRODUCT DESCRIPTOR | 26.0 | mm | 9 | TOB07 | TO | CIG01a | 9 | VENTLTNVENTLTOT | Total Ventilation | NEW PRODUCT | PRODUCT DESCRIPTOR | 10.0 | % | 10 | TOB07 | TO | CIG01a | 10 | CHARFLAV | Characterizing Flavor | NEW PRODUCT | PRODUCT DESCRIPTOR | MENTHOL |
|
|
|
The manufacturing parameter specifications of the cigarette tobacco product as intended for use are represented in the Product Design Parameters ( PD ) domain The following example below shows the target, minimum, and maximum values associated with each of 23 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally. Jira |
---|
showSummary | false |
serverIssue Tracker (JIRA) | serverId | 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 |
---|
key | TOBA-114 |
---|
Note the use of the non-standard variable IDGCMPID the variable IGDCMPID (Ingredient or Component Identifier) in rows 5-6. This tobacco product had two 2 tobacco ingredients with two 2 different tobacco cut sizes. IDGCMPID IGDCMPID identifies to which tobacco ingredient the cut size applies. IDGCMPID IGDCMPID originates in the IT (Tobacco Ingredients) and IN (Non-Tobacco Ingredients) domains. See section Section 3.1.3.1, Ingredients and Additives, for more information.
Dataset wrap |
---|
| Jira |
---|
showSummary | false |
---|
server | Issue Tracker (JIRA) |
serverId | | 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 |
key | TOBA-82 |
---|
Dataset2 |
---|
Row | STUDYID | DOMAIN | SPTOBID | IGDCMPID | PDSEQ | PDPARMCD | PDPARM | PDVALTRG | PDVALMIN | PDVALMAX | PDVALUIDGCMPID |
---|
1 | | PD | CIG01a | | | LENGTH | Length | | | 84.5 | | 2 | TOB07 | PD | CIG01a |
| 2 | CIRCUMF | Circumference | 24.8 | 24.6 | 25 | mm | 3 | TOB07 | PD | CIG01a |
| 3 | TBFLMASS | Tobacco Filler Mass | 783 | 753 | 814 | mg | 4 | TOB07 | PD | CIG01a |
| 4 | MOISTURE | Moisture | 13 | 12 | 14 | % | 5 | TOB07 | PD | CIG01a | | 5 | TOCUTSIZ | Tobacco Cut Size | | | 24 | | 6 | TOB07 | PD | CIG01a | | 6 | TOCUTSIZ | Tobacco Cut Size | | | 29 | | | 7 | TOB07 | PD | CIG01a | | 7 | FLTRVENTVENTLFLT | Filter Ventilation | | | 37 | | 8 | TOB07 | PD | CIG01a |
| 8 | TPNPLGTH | Tipping Paper Length | 31 | 30 | 32 | mm | 9 | TOB07 | PD | CIG01a |
| 9 | CIGBPPORCBPPOR | Cigarette Base Paper Porosity | NANA | | NA55 | CORESTA Unit (Cu) | 10 | TOB07 | PD | CIG01a | | 10 | CBPPERM | Cigarette Base Paper Permeability | | | 55 | | 11 | TOB07 | PD | CIG01a |
| 11 | CBPPORCPBPOR | Cigarette Paper Band Porosity | NA10NA | 0.2 | NA13 | CORESTA Unit (Cu) or cm2/s | 12 | TOB07 | PD | CIG01a |
| 12 | CPBPERM | Cigarette Paper Band Permeability | 10 | 0.2 | 13 | CORESTA Unit (Cu) or cm2/s | 13 | TOB07 | PD | CIG01a |
| 13 | | Cigarette Paper Band Diffusivity | NA | NA | NA | 0.05 | 0.001 | 0.100 | CORESTA Unit (Cu) or cm2/s | 14 | TOB07 | PD | CIG01a | | 14 | CPBWID | Cigarette Paper Band Width | | | 7.3 | | 15 | TOB07 | PD | CIG01a | | 15 | CPBSPC | Cigarette Paper Band Space | 20 | | 20.2 | | 16 | TOB07 | PD | CIG01a | | 16 | FLTREFF | Filter Efficiency | | | | 35N/A | | 17 | TOB07 | PD | CIG01a | | 17 | DPF | Denier Per Filament | 4 | 3.6 | 4.4g/9000m Jira |
---|
| showSummary | false |
---|
server | Issue Tracker (JIRA) | serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45 | key | TOBA-187 |
---|
| 18 | TOB07 | PD | CIG01a | | 18 | TDENIER | Total Denier | | | 30900 | | 19 | TOB07 | PD | CIG01a |
| 19 | FLTRDEN | Filter Density | 0.1234 | 0.105 | 0.1419 | g/cm3 | 20 | TOB07 | PD | CIG01a |
| 20 | FLTRLGTH | Filter Length | 25 | 24.5 | 25.5 | mm | 21 | TOB07 | PD | CIG01a |
| 21 | FLTPRDRP | Filter Pressure Drop | 60 | 51 | 69 | mm H2O | 22 | TOB07 | PD | CIG01a |
| 22 | TORODDEN | Tobacco Rod Density | 0.2678 | 0.2437 | 0.2919 | g/cm3 | 23 | TOB07 | PD | CIG01a |
| 23 | CIGPLGTH | Cigarette Paper Length | 53 | 52 | 54 | mm |
|
Finally, the Tobacco Product Testing ( PT ) domain is used to represent the actual results of testing the manufactured cigarette product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a required Required variable and is set to "DESIGN PARAMETER TESTING" for all records here. As described in the PD example, IGDCMPID is also used here to differentiate 2 records of the same test performed on each of 2 different types of tobacco that are ingredients of the tobacco product. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only one 1 replicate per parameter is shown. Note that PTREPNUM (repetition number) = 1 for all rows.
Dataset wrap |
---|
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | SPTOBID | IGDCMPID | PTSEQ | PTTESTCD | PTTEST | PTCAT | PTORRES | PTORRESU | PTSTRESC | PTSTRESN | PTSTRESU | PTMETHOD | PTREPNUM |
---|
1 | TOB07 | PT | CIG01a |
| | LENGTH | Length | DESIGN PARAMETER TESTING | | mm | | | mm |
| 1 | 2 | TOB07 | PT | CIG01a |
| 2 | CIRCUMF | Circumference | DESIGN PARAMETER TESTING | 24.9 | mm | 24.9 | 24.9 | mm |
| 1 | 3 | TOB07 | PT | CIG01a |
| 3 | TBFLMASS | Tobacco Filler Mass | DESIGN PARAMETER TESTING | 779 | mg | 779 | 779 | mg |
| 1 | 4 | TOB07 | PT | CIG01a |
| 4 | MOISTURE | Moisture | DESIGN PARAMETER TESTING | 13.1 | % | 13.1 | 13.1 | % |
| 1 | 5 | TOB07 | PT | CIG01a | | 5 | TOCUTSIZ1 1 | DESIGN PARAMETER TESTING | 22 | cuts | per inch per inchTOCUTSIZ2 2 | DESIGN PARAMETER TESTING | 27 | mm | 27 | 27 | mm |
| 1 | 7 | TOB07 | PT | CIG01a |
| 7 | FLTRVENTVENTLFLT | Filter Ventilation | DESIGN PARAMETER TESTING | 35 | % | 35 | 35 | % |
| 1 | 8 | TOB07 | PT | CIG01a |
| 8 | TPNPLGTH | Tipping Paper Length | DESIGN PARAMETER TESTING | 30 | mm | 30 | 30 | mm |
| 1 | 9 | TOB07 | PT | CIG01a |
| 9 | CIGBPPORCBPPOR | Cigarette Base Paper Porosity | DESIGN PARAMETER TESTING |
N/A | CORESTA Unit (Cu) | N/A | N/A | CORESTA Unit (Cu) |
| 1 | 10 | TOB07 | PT | CIG01a |
| 10 | CBPPERM | Cigarette Base Paper Permeability | DESIGN PARAMETER TESTING | 50 | cm2/scm2/sCBPPORCPBPOR | Cigarette Paper Band Porosity | DESIGN PARAMETER TESTING |
N/A | CORESTA Unit (Cu) | N/A | N/A | CORESTA Unit (Cu) |
| 1 | 12 | TOB07 | PT | CIG01a |
| 12 | CPBPERM | Cigarette Paper Band Permeability | DESIGN PARAMETER TESTING | 10 | cm^2/scm2/sCu |
| 1 | 13 | TOB07 | PT | CIG01a |
| 13 | CPBDIFF | Cigarette Paper Band Diffusivity | DESIGN PARAMETER TESTING |
N/A | N/A | N/A |
| 1 | 14 | TOB07 | PT | CIG01a |
| 14 | CPBWID | Cigarette Paper Band Width | DESIGN PARAMETER TESTING | 7.1 | mm | 7.1 | 7.1 | mm |
| 1 | 15 | TOB07 | PT | CIG01a |
| 15 | CPBSPC | Cigarette Paper Band Space | DESIGN PARAMETER TESTING | 19.9 | mm | 19.9 | 19.9 | mm |
| 1 | 16 | TOB07 | PT | CIG01a |
| 16 | FLTREFF | Filter Efficiency | DESIGN PARAMETER TESTING | N/AN/A | N/A | % |
| 1 | 17 | TOB07 | PT | CIG01a |
| 17 | DPF | Denier Per Filament | DESIGN PARAMETER TESTING | 4.1 |
| 4.1 | 4.1 | g/9000m |
|
| 1 | 18 | TOB07 | PT | CIG01a |
| 18 | TDENIER | Total Denier | DESIGN PARAMETER TESTING | 29900 | g/9000m | 29900 | 29900 | g/9000m |
| 1 | 19 | TOB07 | PT | CIG01a |
| 19 | FLTRDEN | Filter Density | DESIGN PARAMETER TESTING | 0.1112 | g/cm3 | 0.1112 | 0.1112 | g/cm3 |
| 1 | 20 | TOB07 | PT | CIG01a |
| 20 | FLTRLGTH | Filter Length | DESIGN PARAMETER TESTING | 25 | mm | 25 | 25 | mm |
| 1 | 21 | TOB07 | PT | CIG01a |
| 21 | FLTPRDRP | Filter Pressure Drop | DESIGN PARAMETER TESTING | 62 | mm H2O | 62 | 62 | mm H2O |
| 1 | 22 | TOB07 | PT | CIG01a |
| 22 | TORODDEN | Tobacco Rod Density | DESIGN PARAMETER TESTING | 0.2701 | g/cm3 | 0.2701 | 0.2701 | g/cm3 |
| 1 | 23 | TOB07 | PT | CIG01a |
| 23 | CIGPLGTH | Cigarette Paper Length | DESIGN PARAMETER TESTING | 53 | mm | 53 | 53 | mm |
| 1 |
|
|
References:
- International Organization for Standardization. ISO 9512:2019(en) - Cigarettes — Determination of ventilation — Definitions and measurement principles. ISO; June 2019. Accessed October 15, 2023. https://www.iso.org/obp/ui/#iso:std:iso:9512:ed-3:v1:en
- Song M-A, Benowitz NL, Berman M, et al. Cigarette filter ventilation and its relationship to increasing rates of lung adenocarcinoma. J Natl Cancer Inst. 2017;109(12):djx075. https://wwwdoi.ncbi.nlm.nih.gov/pmc/articles/PMC6059254/org/10.1093/jnci/djx075