Tobacco product HPHC testing results are represented in the PT domain. This example shows HPHC testing with an ENDS device. HPHC testing is conducted on samples of the product of interest, and (if applicable) samples of comparison products. Each product tested would have its own unique sponsorapplicant-defined value for SPTOBID to identify the product. 

...

 

...

The following references were used as guidance for the example below:

  1. Aerosol data used data from: https://www.mdpi.com/2297-8739/8/10/168/htm was from a 3% nicotine solution.

       2. Data for acetaldehyde in solution from Chemical evaluation of electronic cigarettes | Tobacco Control (bmj.com), calculation below

NIC
Dataset wrap
Namept
Rowcaps
Rows Row 1-2:Show Shows the HPHC testing performed for two constituents on Batch 1, Replication 1 for the liquid matrix. The CAS number of the constituent is provided in PTCAS.acetaldehyde from a sample of e-Liquid (as indicated by PTSPEC=E-LIQUID).
Rows 2-4Rows 3-5:Show the HPHC testing performed for three constituents 3 analytes from aerosol produced using the NON-INTENSE SMOKING REGIME for Replicate 1non-intense regimen on a smoking machine. PTSPEC=AEROSOL, SPDEVID indicates the smoking machine used to produce the aerosol, and PTREFID indicates the vaping regimen.
Rows 65-7:Show the HPHC testing performed for three constituents using the INTENSE SMOKING REGIME for Replicate 13 analytes using the intense regimen on the same smoking machine (PTREFID=INTENSE REGIMEN).
Dataset2
RowSTUDYIDDOMAINSPTOBIDSPDEVIDPTSEQPTREFID
PTCAS
PTTESTCDPTTESTPTCATPTSCATPTORRESPTORRESUPTSTRESCPTSTRESNPTSTRESUPTSPECPTREPNUMPTDTC
1TOB08PTENDS02a
1
75-07-0ACETALD

ACTALDAcetaldehydeHPHC TESTINGHPHC7.9µg/mL7.97.9µg/mLE-LIQUID12022-09-30
2TOB08PTENDS02aPUFFMASTER3K2
Non
NON-
intense
1954-11-05
INTENSE REGIMENNICOTINENicotineHPHC TESTINGHPHC53.5µg/puff53.553.5µg/puffAEROSOL12022-09-30
3TOB08PTENDS02aPUFFMASTER3K3
Non
NON-
intense75-07-0ACETALD
INTENSE REGIMENACTALDAcetaldehydeHPHC TESTINGHPHC34.7ng/puff34.734.7ng/puffAEROSOL12022-09-30
4TOB08PTENDS02aPUFFMASTER3K4
Non
NON-
intense65-85-0
INTENSE REGIMENBNZOICACBenzoic AcidHPHC TESTINGOther43.3µg/puff43.343.3µg/puffAEROSOL12022-09-30
5TOB08PTENDS02aPUFFMASTER3K5
Intense1954-11-05
INTENSE REGIMENNICOTINE
NIC
NicotineHPHC TESTINGHPHC105µg/puff105105µg/puffAEROSOL22022-09-30
6TOB08PTENDS02aPUFFMASTER3K6
Intense75-07-0ACETALD
INTENSE REGIMENACTALDAcetaldehydeHPHC TESTINGHPHC43.5ng/puff43.543.5ng/puffAEROSOL22022-09-30
7TOB08PTENDS02aPUFFMASTER3K7
Intense65-85-
INTENSE REGIMENBNZOICAC
0
Benzoic AcidHPHC TESTINGOther84.1µg/puff84.184.1µg/puffAEROSOL22022-09-30

The identifying characteristics of the smoking machine are represented in the Device Identifiers DI reference dataset.

Dataset wrap
titlelb.xpt
Namedi
Dataset2
RowSTUDYIDDOMAINSPDEVIDDISEQDIPARMCDDIPARMDIVAL
1TOB07DIPUFFMASTER3K1DEVTYPEDevice TypeSmoking Machine
2TOB07DIPUFFMASTER3K2MANUFManufacturerAcme
3TOB07DIPUFFMASTER3K3TRADENAMTrade NamePuffMaster 3000

Details of the smoking vaping regimen performed by the smoking machine are represented as device in-use properties, linked to the HPHC testing results in PT above by matching values of PTREFID/DUREFID = "Non-intense Regimen". 

Dataset wrap
Namedu
Rowcaps
Rows 1-9:Show the parameters of the non-intense vaping regimen.
Rows 8-9:Note the use of DUGRPID to group these records together to indicate that puff pause and puff pause interval are related records. Taken together, they indicate that this vaping regimen pauses for 60 seconds every 10 puffs.
Rows 10-18:Show the parameters of the intense vaping regimen.
Rows 17-18:Note the use of DUGRPID to group these records together to indicate that puff pause and puff pause interval are related records. Taken together, they indicate that this vaping regimen pauses for 30 seconds every 10 puffs.
Dataset2
RowSTUDYIDDOMAINSPDEVIDDUSEQDUREFIDDUGRPIDDUTESTCDDUTESTDUORRESDUORRESUDUSTRESCDUSTRESNDUSTRESU
1

TOB07

DUPUFFMASTER3K1NonNON-intense RegimenINTENSE REGIMEN
PUFFPROFPuff ProfileSQUARE
SQUARE

2

TOB07

DUPUFFMASTER3K2NonNON-intense RegimenINTENSE REGIMEN

PUFFDUR

Puff Duration

41.25

sec

41.25

4
1.25

sec

3

TOB07

DUPUFFMASTER3K3NonNON-intense RegimenINTENSE REGIMEN

PUFFINT

Puff Interval

37

PUFF/min

37

3
7

PUFF/min

4

TOB07

DUPUFFMASTER3K4NonNON-intense RegimenINTENSE REGIMEN

PUFFBLCK

Puff Block

25

%

25

25

%

5

TOB07

DUPUFFMASTER3K5NonNON-intense RegimenINTENSE REGIMEN
NUMPUFF

PUFFNUM

Total Number of Puffs

200

PUFF

200

200

PUFF

6

TOB07

DUPUFFMASTER3K6NonNON-intense RegimenINTENSE REGIMEN
PUFFVOLPuff Volume

10

mL

10

10

mL

7

TOB07

DUPUFFMASTER3K7NonNON-intense RegimenINTENSE REGIMEN
PUFFRNGPuff Range

100-200


100-200



8

TOB07

DUPUFFMASTER3K8NonNON-intense RegimenINTENSE REGIMEN1PUFFPAUSPuff Pause

60

s

60

60

s

9TOB07DUPUFFMASTER3K9NonNON-intense RegimenINTENSE REGIMEN1PUFFPINTPuff Pause Interval

10

PUFF

10

10

PUFF

10

TOB07

DUPUFFMASTER3K1Intense RegimenINTENSE REGIMEN
PUFFPROFPuff ProfileSQUARE
SQUARE

11

TOB07

DUPUFFMASTER3K2Intense RegimenINTENSE REGIMEN

PUFFDUR

Puff Duration

43.25

sec

43.25

4
3.25

sec

12

TOB07

DUPUFFMASTER3K3Intense RegimenINTENSE REGIMEN

PUFFINT

Puff Interval

310

PUFF/min

310

3
10

PUFF/min

13

TOB07

DUPUFFMASTER3K4Intense RegimenINTENSE REGIMEN

PUFFBLCK

Puff Block

25

%

25

25

%

14

TOB07

DUPUFFMASTER3K5Intense RegimenINTENSE REGIMEN
NUMPUFFPUFFNUMTotal Number of Puffs

300

PUFF

300

300

PUFF

15

TOB07

DUPUFFMASTER3K6Intense RegimenINTENSE REGIMEN
PUFFVOLPuff Volume

1025

mL

1025

10
25

mL

16

TOB07

DUPUFFMASTER3K7Intense RegimenINTENSE REGIMEN
PUFFRNGPuff Range

100-200400


100-200400



17

TOB07

DUPUFFMASTER3K8Intense RegimenINTENSE REGIMEN12PUFFPAUSPuff Pause

10

s

10

10

s

18TOB07DUPUFFMASTER3K9Intense RegimenINTENSE REGIMEN12PUFFPINTPuff Pause Interval

2030

PUFF

2030

20
30

PUFF