Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The following This example illustrates the representation of a cigarette product's identifiers and descriptors using the TO domain. Note that this example makes use of TOCAT (Category uses TOSCAT (Subcategory of Tobacco Product Prod ID Element, a permissible variable) to emphasize and differentiate the two 2 distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors. 

Dataset wrap
Nameto
Dataset2
RowSTUDYIDDOMAINSPTOBIDTOSEQTOPARMCDTOPARMTOCATTOSCATTOVALTOVALU
1TOB07TOCIG01a

1

TBPRDCATTobacco Product CategoryNEW PRODUCTPRODUCT IDENTIFIER
Cigarette
Cigarettes
2TOB07TOCIG01a2TBPRSCATTobacco Product SubcategoryNEW PRODUCTPRODUCT IDENTIFIERFiltered
, Combusted

3TOB07TOCIG01a3MANUFManufacturerNEW PRODUCTPRODUCT IDENTIFIERJoes Cigs USA
4TOB07TOCIG01a4TRADENAMTrade NameNEW PRODUCTPRODUCT IDENTIFIERTreetop Menthol King Size
5TOB07TOCIG01a5PACKTYPPackage TypeNEW PRODUCTPRODUCT DESCRIPTORHARD PACK
6TOB07TOCIG01a6PRDQUANProduct QuantityNEW PRODUCTPRODUCT DESCRIPTOR20CIGARETTE
7TOB07TOCIG01a7LENGTHLengthNEW PRODUCTPRODUCT DESCRIPTOR86.0mm
8TOB07TOCIG01a8CIRCUMFCircumferenceNEW PRODUCTPRODUCT DESCRIPTOR26.0mm
9TOB07TOCIG01a9
VENTLTN
VENTLTOTTotal VentilationNEW PRODUCTPRODUCT DESCRIPTOR10.0%
10TOB07TOCIG01a10CHARFLAVCharacterizing FlavorNEW PRODUCTPRODUCT DESCRIPTORMENTHOL

The manufacturing parameter specifications of the cigarette tobacco product as used intended for use are represented in the Product Design Parameters ( PD ) domain  The following example below shows the target, minimum, and maximum values associated with each of 23 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.

Note the use of the variable IGDCMPID (Ingredient or Component Identifier) in rows 5-6. This tobacco product had 2 tobacco ingredients with 2 different tobacco cut sizes. IGDCMPID identifies to which tobacco ingredient the cut size applies. IGDCMPID originates in the IT (Tobacco Ingredients) and IN (Non-Tobacco Ingredients) domains. See Section 3.1.3.1, Ingredients and Additives, for more information.

Dataset wrap
Namepd
Dataset2
RowSTUDYIDDOMAINSPTOBIDIGDCMPIDPDSEQPDPARMCDPDPARMPDVALTRGPDVALMINPDVALMAXPDVALU
1

TOB07

PDCIG01a


1

LENGTHLength

84

83.5

84.5

mm

2TOB07PDCIG01a
2CIRCUMFCircumference24.824.625mm
3TOB07PDCIG01a
3TBFLMASSTobacco Filler Mass783753814mg
4TOB07PDCIG01a
4MOISTUREMoisture141312.0913.9114%
5TOB07PDCIG01a

Burley tobacco

5TOCUTSIZTobacco Cut Size

22

20

24

cuts/in2in

6TOB07PDCIG01a

Reconstituted tobacco

6TOCUTSIZTobacco Cut Size

27

25

29

mm

7TOB07PDCIG01a


7FLTRVENTVENTLFLTFilter Ventilation

30

23

37

%

8TOB07PDCIG01a
8TPNPLGTHTipping Paper Length313032mm
9TOB07PDCIG01a
9CIGBPPORCBPPOR

Cigarette Base Paper Porosity

NA

50

NA

45

NA55CORESTA Unit (Cu)
10TOB07PDCIG01a


10CIGBPPORCBPPERMCigarette Base Paper Permeability

50

45

55

CORESTA Unit (Cu)

11TOB07PDCIG01a
11BNDPORCPBPORCigarette Paper Band PorosityNA10NA0.2NA13CORESTA Unit (Cu) or cm2/s
12TOB07PDCIG01a
12BNDPERMCPBPERMCigarette Paper Band Permeability100.213CORESTA Unit (Cu) or cm2/s
13TOB07PDCIG01a
13BNDDIF

CPBDIFF

Cigarette Paper Band DiffusivityNANANA0.050.0010.100CORESTA Unit (Cu) or cm2/s
14TOB07PDCIG01a


14CPBNDWIDCPBWIDCigarette Paper Band Width

7

6.7

7.3

mm

15TOB07PDCIG01a


15CPBNDSPCCPBSPCCigarette Paper Band Space20

19.8

20.2

mm

16TOB07PDCIG01a


16FLTREFFFilter Efficiency

NA30

N/A

25

35N/A

%

17TOB07PDCIG01a


17DPFDenier Per Filament43.64.44


18TOB07PDCIG01a


18TDENIERTotal Denier

30000

29100

30900

g/9000 m9000m

19TOB07PDCIG01a
19FLTRDENFilter Density0.12340.1050.1419g/cm3
20TOB07PDCIG01a
20FLTRLGTHFilter Length2524.525.5mm
21TOB07PDCIG01a
21FLTPRDRPFilter Pressure Drop605169mm H2O
22TOB07PDCIG01a
22TORODDENTobacco Rod Density0.26780.24370.2919g/cm3
23TOB07PDCIG01a
23CIGPLGTHCigarette Paper LengthCIGPLGTH535254mm

Finally, the Tobacco Product Testing ( PT ) domain is used to represent the actual results of testing the manufactured cigarette product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a required Required variable and is set to "DESIGN PARAMETER TESTING" for all records here. As described in the PD example, IGDCMPID is also used here to differentiate 2 records of the same test performed on each of 2 different types of tobacco that are ingredients of the tobacco product. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only one 1 replicate per parameter is shown. Note that PTREPNUM (repetition number) = 1 for all rows.

Dataset wrap
Namept
Dataset2
RowSTUDYIDDOMAINSPTOBIDIGDCMPIDPTSEQPTTESTCDPTTESTPTCATPTORRESPTORRESUPTSTRESCPTSTRESNPTSTRESUPTMETHODPTREPNUM
1TOB07PTCIG01a

1

LENGTHLengthDESIGN PARAMETER TESTING

83.9

mm

83.9

83.9

mm
1
2TOB07PTCIG01a
2CIRCUMFCircumferenceDESIGN PARAMETER TESTING24.9mm24.924.9mm
1
3TOB07PTCIG01a
3TBFLMASSTobacco Filler MassDESIGN PARAMETER TESTING779mg779779mg
1
4TOB07PTCIG01a
4MOISTUREMoistureDESIGN PARAMETER TESTING13.1%13.113.1%
1
5TOB07PTCIG01a

Burley tobacco

5
TOCUTSIZ1
TOCUTSIZTobacco Cut Size
1
DESIGN PARAMETER TESTING22cuts
per inch
/in2222cuts
per inch
/in
1
6TOB07PTCIG01a

Reconstituted tobacco

6
TOCUTSIZ2
TOCUTSIZTobacco Cut Size
2
DESIGN PARAMETER TESTING27mm2727mm
1
7TOB07PTCIG01a
7
FLTRVENT
VENTLFLTFilter VentilationDESIGN PARAMETER TESTING35%3535%
1
8TOB07PTCIG01a
8TPNPLGTHTipping Paper LengthDESIGN PARAMETER TESTING30mm3030mm
1
9TOB07PTCIG01a
9
CIGBPPOR
CBPPORCigarette Base Paper PorosityDESIGN PARAMETER TESTING
N/ACORESTA Unit (Cu)N/AN/A
48Cu4848Cu
CORESTA Unit (Cu)

1
10TOB07PTCIG01a
10
CIGBPPERM
CBPPERMCigarette Base Paper PermeabilityDESIGN PARAMETER TESTING50
cm2/s
Cu5050
cm2/s
Cu
1
11TOB07PTCIG01a
11
BNDDIF
CPBPORCigarette Paper Band PorosityDESIGN PARAMETER TESTING
N/ACORESTA Unit (Cu)N/AN/A
9.8Cu9.89.8Cu
CORESTA Unit (Cu)

1
12TOB07PTCIG01a
12
BNDDIF
CPBPERMCigarette Paper Band PermeabilityDESIGN PARAMETER TESTING10
cm^2/s
Cu1010
cm2/s
Cu
1
13TOB07PTCIG01a
13
BNDDIF
CPBDIFFCigarette Paper Band DiffusivityDESIGN PARAMETER TESTING0.06
N/AN/A
cm2/s0.060.06cm2/s
N/A

1
14TOB07PTCIG01a
14
CPBNDWID
CPBWIDCigarette Paper Band WidthDESIGN PARAMETER TESTING7.1mm7.17.1mm
1
15TOB07PTCIG01a
15
CPBNDSPC
CPBSPCCigarette Paper Band SpaceDESIGN PARAMETER TESTING19.9mm19.919.9mm
1
16TOB07PTCIG01a
16FLTREFFFilter EfficiencyDESIGN PARAMETER TESTING
N/A
28%
N/A
2828
N/A
%
1
17TOB07PTCIG01a
17DPFDenier Per FilamentDESIGN PARAMETER TESTING4.1
4.14.1
/filament


1
18TOB07PTCIG01a
18
DENIER
TDENIERTotal DenierDESIGN PARAMETER TESTING29900g/9000m2990029900g/9000m
1
19TOB07PTCIG01a
19FLTRDENFilter DensityDESIGN PARAMETER TESTING0.1112g/cm30.11120.1112g/cm3
1
20TOB07PTCIG01a
20FLTRLGTHFilter LengthDESIGN PARAMETER TESTING25mm2525mm
1
21TOB07PTCIG01a
21FLTPRDRPFilter Pressure DropDESIGN PARAMETER TESTING62mm H2O6262mm H2O
1
22TOB07PTCIG01a
22TORODDENTobacco Rod DensityDESIGN PARAMETER TESTING0.2701g/cm30.27010.2701g/cm3
1
23TOB07PTCIG01a
23CIGPLGTHCigarette Paper LengthDESIGN PARAMETER TESTING53mm5353mm
1

References:

  1. International Organization for Standardization. ISO 9512:2019(en) - Cigarettes — Determination of ventilation — Definitions and measurement principles. ISO; June 2019. Accessed October 15, 2023. https://www.iso.org/obp/ui/#iso:std:iso:9512:ed-3:v1:en
  2. Song M-A, Benowitz NL, Berman M, et al. Cigarette filter ventilation and its relationship to increasing rates of lung adenocarcinoma. J Natl Cancer Inst. 2017;109(12):djx075. https://wwwdoi.ncbi.nlm.nih.gov/pmc/articles/PMC6059254/org/10.1093/jnci/djx075