The examples in this sub-section illustrate how to represent lists of design parameter specifications and testing for conformance to those specifications using three tobacco product categories: cigarettes (Example 1), ENDS devices (Example 2) and smokeless tobacco products (Example 3). Each example starts with a TO dataset, followed by a product design parameters (PD) dataset and a tobacco product testing (PT) dataset.
Note that tobacco product testing for conformance to design parameters would typically require multiple replicates for each parameter being tested. In SDTM, each replicate would be represented in its own record, differentiated by using the PTREPNUM variable (repetition number), which would be set to values of 1 through n (where n = the total number of replicates being tested). For simplicity of review, each example does make use of the PTREPNUM variable, but only for one record (one repetition). In reality, if only one record for a given parameter or analyte is collected, the PTREPNUM variable would not be used.
Example
This example illustrates the representation of a cigarette product's identifiers and descriptors using the TO domain. Note that this example uses TOSCAT (Subcategory of Tobacco Prod ID Element, a permissible variable) to emphasize and differentiate the 2 distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors.
to.xpt
to.xpt
Row
STUDYID
DOMAIN
SPTOBID
TOSEQ
TOPARMCD
TOPARM
TOCAT
TOSCAT
TOVAL
TOVALU
1
TOB07
TO
CIG01a
1
TBPRDCAT
Tobacco Product Category
NEW PRODUCT
PRODUCT IDENTIFIER
Cigarettes
2
TOB07
TO
CIG01a
2
TBPRSCAT
Tobacco Product Subcategory
NEW PRODUCT
PRODUCT IDENTIFIER
Filtered
3
TOB07
TO
CIG01a
3
MANUF
Manufacturer
NEW PRODUCT
PRODUCT IDENTIFIER
Joes Cigs USA
4
TOB07
TO
CIG01a
4
TRADENAM
Trade Name
NEW PRODUCT
PRODUCT IDENTIFIER
Treetop Menthol King Size
5
TOB07
TO
CIG01a
5
PACKTYP
Package Type
NEW PRODUCT
PRODUCT DESCRIPTOR
HARD PACK
6
TOB07
TO
CIG01a
6
PRDQUAN
Product Quantity
NEW PRODUCT
PRODUCT DESCRIPTOR
20
CIGARETTE
7
TOB07
TO
CIG01a
7
LENGTH
Length
NEW PRODUCT
PRODUCT DESCRIPTOR
86.0
mm
8
TOB07
TO
CIG01a
8
CIRCUMF
Circumference
NEW PRODUCT
PRODUCT DESCRIPTOR
26.0
mm
9
TOB07
TO
CIG01a
9
VENTLTOT
Total Ventilation
NEW PRODUCT
PRODUCT DESCRIPTOR
10.0
%
10
TOB07
TO
CIG01a
10
CHARFLAV
Characterizing Flavor
NEW PRODUCT
PRODUCT DESCRIPTOR
MENTHOL
$warningHtml
The manufacturing parameter specifications of the cigarette tobacco product as intended for use are represented in the PD domain The following example shows the target, minimum, and maximum values associated with each of 23 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.
Note the use of the variable IGDCMPID (Ingredient or Component Identifier) in rows 5-6. This tobacco product had 2 tobacco ingredients with 2 different tobacco cut sizes. IGDCMPID identifies to which tobacco ingredient the cut size applies. IGDCMPID originates in the IT (Tobacco Ingredients) and IN (Non-Tobacco Ingredients) domains. See Section 3.1.3.1, Ingredients and Additives, for more information.
pd.xpt
pd.xpt
Row
STUDYID
DOMAIN
SPTOBID
IGDCMPID
PDSEQ
PDPARMCD
PDPARM
PDVALTRG
PDVALMIN
PDVALMAX
PDVALU
1
TOB07
PD
CIG01a
1
LENGTH
Length
84
83.5
84.5
mm
2
TOB07
PD
CIG01a
2
CIRCUMF
Circumference
24.8
24.6
25
mm
3
TOB07
PD
CIG01a
3
TBFLMASS
Tobacco Filler Mass
783
753
814
mg
4
TOB07
PD
CIG01a
4
MOISTURE
Moisture
13
12
14
%
5
TOB07
PD
CIG01a
Burley tobacco
5
TOCUTSIZ
Tobacco Cut Size
22
20
24
cuts/in
6
TOB07
PD
CIG01a
Reconstituted tobacco
6
TOCUTSIZ
Tobacco Cut Size
27
25
29
mm
7
TOB07
PD
CIG01a
7
VENTLFLT
Filter Ventilation
30
23
37
%
8
TOB07
PD
CIG01a
8
TPNPLGTH
Tipping Paper Length
31
30
32
mm
9
TOB07
PD
CIG01a
9
CBPPOR
Cigarette Base Paper Porosity
50
45
55
Cu
10
TOB07
PD
CIG01a
10
CBPPERM
Cigarette Base Paper Permeability
50
45
55
Cu
11
TOB07
PD
CIG01a
11
CPBPOR
Cigarette Paper Band Porosity
10
0.2
13
Cu
12
TOB07
PD
CIG01a
12
CPBPERM
Cigarette Paper Band Permeability
10
0.2
13
Cu
13
TOB07
PD
CIG01a
13
CPBDIFF
Cigarette Paper Band Diffusivity
0.05
0.001
0.100
cm2/s
14
TOB07
PD
CIG01a
14
CPBWID
Cigarette Paper Band Width
7
6.7
7.3
mm
15
TOB07
PD
CIG01a
15
CPBSPC
Cigarette Paper Band Space
20
19.8
20.2
mm
16
TOB07
PD
CIG01a
16
FLTREFF
Filter Efficiency
30
25
35
%
17
TOB07
PD
CIG01a
17
DPF
Denier Per Filament
4
3.6
4.4
18
TOB07
PD
CIG01a
18
TDENIER
Total Denier
30000
29100
30900
g/9000m
19
TOB07
PD
CIG01a
19
FLTRDEN
Filter Density
0.1234
0.105
0.1419
g/cm3
20
TOB07
PD
CIG01a
20
FLTRLGTH
Filter Length
25
24.5
25.5
mm
21
TOB07
PD
CIG01a
21
FLTPRDRP
Filter Pressure Drop
60
51
69
mm H2O
22
TOB07
PD
CIG01a
22
TORODDEN
Tobacco Rod Density
0.2678
0.2437
0.2919
g/cm3
23
TOB07
PD
CIG01a
23
CIGPLGTH
Cigarette Paper Length
53
52
54
mm
$warningHtml
Finally, the PT domain is used to represent the actual results of testing the manufactured cigarette product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a Required variable and is set to "DESIGN PARAMETER TESTING" for all records here. As described in the PD example, IGDCMPID is also used here to differentiate 2 records of the same test performed on each of 2 different types of tobacco that are ingredients of the tobacco product. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only 1 replicate per parameter is shown. Note that PTREPNUM (repetition number) = 1 for all rows.
pt.xpt
pt.xpt
Row
STUDYID
DOMAIN
SPTOBID
IGDCMPID
PTSEQ
PTTESTCD
PTTEST
PTCAT
PTORRES
PTORRESU
PTSTRESC
PTSTRESN
PTSTRESU
PTMETHOD
PTREPNUM
1
TOB07
PT
CIG01a
1
LENGTH
Length
DESIGN PARAMETER TESTING
83.9
mm
83.9
83.9
mm
1
2
TOB07
PT
CIG01a
2
CIRCUMF
Circumference
DESIGN PARAMETER TESTING
24.9
mm
24.9
24.9
mm
1
3
TOB07
PT
CIG01a
3
TBFLMASS
Tobacco Filler Mass
DESIGN PARAMETER TESTING
779
mg
779
779
mg
1
4
TOB07
PT
CIG01a
4
MOISTURE
Moisture
DESIGN PARAMETER TESTING
13.1
%
13.1
13.1
%
1
5
TOB07
PT
CIG01a
Burley tobacco
5
TOCUTSIZ
Tobacco Cut Size
DESIGN PARAMETER TESTING
22
cuts/in
22
22
cuts/in
1
6
TOB07
PT
CIG01a
Reconstituted tobacco
6
TOCUTSIZ
Tobacco Cut Size
DESIGN PARAMETER TESTING
27
mm
27
27
mm
1
7
TOB07
PT
CIG01a
7
VENTLFLT
Filter Ventilation
DESIGN PARAMETER TESTING
35
%
35
35
%
1
8
TOB07
PT
CIG01a
8
TPNPLGTH
Tipping Paper Length
DESIGN PARAMETER TESTING
30
mm
30
30
mm
1
9
TOB07
PT
CIG01a
9
CBPPOR
Cigarette Base Paper Porosity
DESIGN PARAMETER TESTING
48
Cu
48
48
Cu
1
10
TOB07
PT
CIG01a
10
CBPPERM
Cigarette Base Paper Permeability
DESIGN PARAMETER TESTING
50
Cu
50
50
Cu
1
11
TOB07
PT
CIG01a
11
CPBPOR
Cigarette Paper Band Porosity
DESIGN PARAMETER TESTING
9.8
Cu
9.8
9.8
Cu
1
12
TOB07
PT
CIG01a
12
CPBPERM
Cigarette Paper Band Permeability
DESIGN PARAMETER TESTING
10
Cu
10
10
Cu
1
13
TOB07
PT
CIG01a
13
CPBDIFF
Cigarette Paper Band Diffusivity
DESIGN PARAMETER TESTING
0.06
cm2/s
0.06
0.06
cm2/s
1
14
TOB07
PT
CIG01a
14
CPBWID
Cigarette Paper Band Width
DESIGN PARAMETER TESTING
7.1
mm
7.1
7.1
mm
1
15
TOB07
PT
CIG01a
15
CPBSPC
Cigarette Paper Band Space
DESIGN PARAMETER TESTING
19.9
mm
19.9
19.9
mm
1
16
TOB07
PT
CIG01a
16
FLTREFF
Filter Efficiency
DESIGN PARAMETER TESTING
28
%
28
28
%
1
17
TOB07
PT
CIG01a
17
DPF
Denier Per Filament
DESIGN PARAMETER TESTING
4.1
4.1
4.1
1
18
TOB07
PT
CIG01a
18
TDENIER
Total Denier
DESIGN PARAMETER TESTING
29900
g/9000m
29900
29900
g/9000m
1
19
TOB07
PT
CIG01a
19
FLTRDEN
Filter Density
DESIGN PARAMETER TESTING
0.1112
g/cm3
0.1112
0.1112
g/cm3
1
20
TOB07
PT
CIG01a
20
FLTRLGTH
Filter Length
DESIGN PARAMETER TESTING
25
mm
25
25
mm
1
21
TOB07
PT
CIG01a
21
FLTPRDRP
Filter Pressure Drop
DESIGN PARAMETER TESTING
62
mm H2O
62
62
mm H2O
1
22
TOB07
PT
CIG01a
22
TORODDEN
Tobacco Rod Density
DESIGN PARAMETER TESTING
0.2701
g/cm3
0.2701
0.2701
g/cm3
1
23
TOB07
PT
CIG01a
23
CIGPLGTH
Cigarette Paper Length
DESIGN PARAMETER TESTING
53
mm
53
53
mm
1
$warningHtml
References:
International Organization for Standardization. ISO 9512:2019(en) - Cigarettes — Determination of ventilation — Definitions and measurement principles. ISO; June 2019. Accessed October 15, 2023. https://www.iso.org/obp/ui/#iso:std:iso:9512:ed-3:v1:en
Song M-A, Benowitz NL, Berman M, et al. Cigarette filter ventilation and its relationship to increasing rates of lung adenocarcinoma. J Natl Cancer Inst. 2017;109(12):djx075. https://doi.org/10.1093/jnci/djx075
Example
The following example illustrates the representation of an ENDS tobacco product's identifiers and descriptors using the TO domain. Note that this example uses TOSCAT to emphasize and differentiate the 2 distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors.
to.xpt
to.xpt
Row
STUDYID
DOMAIN
SPTOBID
TOSEQ
TOPARMCD
TOPARM
TOCAT
TOSCAT
TOVAL
TOVALU
1
TOB09
TO
VAPE-Z27
1
TBPRDCAT
Tobacco Product Category
NEW PRODUCT
PRODUCT IDENTIFIER
Electronic Nicotine Delivery Systems (ENDS) (Vapes)
2
TOB09
TO
VAPE-Z27
2
TBPRSCAT
Tobacco Product Subcategory
NEW PRODUCT
PRODUCT IDENTIFIER
Closed E-Cigarette
3
TOB09
TO
VAPE-Z27
3
MANUF
Manufacturer
NEW PRODUCT
PRODUCT IDENTIFIER
Joes Vapes USA
4
TOB09
TO
VAPE-Z27
4
TRADENAM
Trade Name
NEW PRODUCT
PRODUCT IDENTIFIER
Everyday Rich Tobacco
5
TOB09
TO
VAPE-Z27
5
PACKTYP
Package Type
NEW PRODUCT
PRODUCT DESCRIPTOR
BOX
6
TOB09
TO
VAPE-Z27
6
PRDQUAN
Product Quantity
NEW PRODUCT
PRODUCT DESCRIPTOR
1
E-CIGARETTE
7
TOB09
TO
VAPE-Z27
7
LENGTH
Length
NEW PRODUCT
PRODUCT DESCRIPTOR
107.2
mm
8
TOB09
TO
VAPE-Z27
8
DIAMETER
Diameter
NEW PRODUCT
PRODUCT DESCRIPTOR
9
mm
9
TOB09
TO
VAPE-Z27
9
NICTNCNC
Nicotine Concentration
NEW PRODUCT
PRODUCT DESCRIPTOR
2
mg/L
10
TOB09
TO
VAPE-Z27
10
PRPYLGLY
Propylene Glycol
NEW PRODUCT
PRODUCT DESCRIPTOR
50
%
11
TOB09
TO
VAPE-Z27
11
VEGGLY
Vegetable Glycerin
NEW PRODUCT
PRODUCT DESCRIPTOR
50
%
12
TOB09
TO
VAPE-Z27
12
CHARFLAV
Characterizing Flavor
NEW PRODUCT
PRODUCT DESCRIPTOR
Tobacco
13
TOB09
TO
VAPE-Z27
13
ELQDVOL
E-Liquid Volume
NEW PRODUCT
PRODUCT DESCRIPTOR
1
mL
14
TOB09
TO
VAPE-Z27
14
BATCAPC
Battery Capacity
NEW PRODUCT
PRODUCT DESCRIPTOR
600
mAh
15
TOB09
TO
VAPE-Z27
15
DSCRTIND
Disposable Cartridge Indicator
NEW PRODUCT
PRODUCT DESCRIPTOR
Y
$warningHtml
The manufacturing parameter specifications of the ENDS product as intended for used are represented in the PD domain. The following example shows the target, minimum, and maximum values associated with each of 33 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.
pd.xpt
pd.xpt
Row
STUDYID
DOMAIN
SPTOBID
PDSEQ
PDPARMCD
PDPARM
PDVALTRG
PDVALMIN
PDVALMAX
PDVALU
1
TOB09
PD
VAPE-Z27
1
DRWRST
Draw Resistance
90.0
80.0
120.0
mm H2O
2
TOB09
PD
VAPE-Z27
2
PUFCNT
Puff Count
300
290
310
3
TOB09
PD
VAPE-Z27
3
CRTVOL
Cartridge Volume
3
1
5
mL
4
TOB09
PD
VAPE-Z27
4
HTELNUM
Number of Heating Elements
1
1
1
5
TOB09
PD
VAPE-Z27
5
HTELGTH
Heating Element Length
3
2.7
3.3
mm
6
TOB09
PD
VAPE-Z27
6
HTEDIAM
Heating Element Diameter
3
2.9
3.2
mm
7
TOB09
PD
VAPE-Z27
7
HTELRST
Heating Element Resistance
0.75
0.25
1.5
ohm
8
TOB09
PD
VAPE-Z27
8
HTELRNG
Heating Element Range
175
100
250
C
9
TOB09
PD
VAPE-Z27
9
HTELCFG
Heating Element Configuration
SPIRAL
SPIRAL
SPIRAL
10
TOB09
PD
VAPE-Z27
10
BTVLTORG
Battery Voltage Operating Range
4.5
3
6
V
11
TOB09
PD
VAPE-Z27
11
BTCRTORG
Battery Current Operating Range
1000
650
1600
mAh
12
TOB09
PD
VAPE-Z27
12
BATCAPC
Battery Capacity
1100
800
3000
mAh
13
TOB09
PD
VAPE-Z27
13
BATNOMV
Battery Nominal Voltage
4.2
4.0
4.5
V
14
TOB09
PD
VAPE-Z27
14
BTCRTRT
Battery Current Rating
2500
2000
2800
mA
15
TOB09
PD
VAPE-Z27
15
BTCHTPL
Battery Charging Temperature Limits
200
100
315
C
16
TOB09
PD
VAPE-Z27
16
BTDCTMPL
Battery Discharge Temperature Limits
20
-20
60
C
17
TOB09
PD
VAPE-Z27
17
BTENDCV
Battery End of Discharge Voltage
3.0
2.0
3.5
V
18
TOB09
PD
VAPE-Z27
18
BTMXCHC
Battery Maximum Charging Current
24
20
30
mA
19
TOB09
PD
VAPE-Z27
19
BTMXDCC
Battery Maximum Discharging Current
2700
2400
3000
mA
20
TOB09
PD
VAPE-Z27
20
BTULCHV
Battery Upper Limits Charging Voltage
4.2
4.1
4.3
V
21
TOB09
PD
VAPE-Z27
21
PDUVOR
PDU Voltage Operating Range
3.7
3.2
4.2
V
22
TOB09
PD
VAPE-Z27
22
PDUCOR
PDU Current Operating Range
1200
850
1800
mA
23
TOB09
PD
VAPE-Z27
23
PDUTCTOF
PDU Temperature Cut-off
70
55
65
C
24
TOB09
PD
VAPE-Z27
24
AIRFLRT
Airflow Rate
720
700
740
L/min
25
TOB09
PD
VAPE-Z27
25
PDUCRCOF
PDU Current Cut-off
35
20
50
mA
26
TOB09
PD
VAPE-Z27
26
INHAERT
Inhaled Aerosol Temperature
37
35
40
C
27
TOB09
PD
VAPE-Z27
27
VENTLTOT
Total Ventilation
50
40
60
%
28
TOB09
PD
VAPE-Z27
28
ELQDVISC
E-Liquid Viscosity
500
75
1130
mPa/s
29
TOB09
PD
VAPE-Z27
29
ELQDVOL
E-liquid Volume
60
10
120
mL
30
TOB09
PD
VAPE-Z27
30
PNUMCNC
Particle Number Concentration
500
108
1010
/cm3
31
TOB09
PD
VAPE-Z27
31
CTMDDIAM
Count Median Diameter
200
150
250
nm
32
TOB09
PD
VAPE-Z27
32
PM2.5
Particulate Matter 2.5
25
12
35
ug/m3
$warningHtml
Finally, the PT domain is used to represent the actual results of testing the manufactured ENDS product for conformance to the tobacco product design parameters shown in PD. PTCAT is a Required variable and is set to "DESIGN PARAMETER TESTING" for all records here. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only 1 replicate per parameter is shown. Note that PTREPNUM (repetition number) = 1 for all rows.
pt.xpt
pt.xpt
Row
STUDYID
DOMAIN
SPTOBID
PTSEQ
PTREFID
PTTESTCD
PTTEST
PTTSTCND
PTCAT
PTSCAT
PTORRES
PTORRESU
PTSTRESC
PTSTRESN
PTSTRESU
PTREPNUM
1
TOB09
PT
VAPE-Z27
1
DRWRST
Draw Resistance
DESIGN PARAMETER TESTING
91
mm H2O
91
91
mm H2O
1
2
TOB09
PT
VAPE-Z27
2
PUFCNT
Puff Count
DESIGN PARAMETER TESTING
309
309
309
1
3
TOB09
PT
VAPE-Z27
3
CRTVOL
Cartridge Volume
DESIGN PARAMETER TESTING
3.09
mL
3.09
3.09
mL
1
4
TOB09
PT
VAPE-Z27
4
HTELNUM
Number of Heating Elements
DESIGN PARAMETER TESTING
1
1
1
1
5
TOB09
PT
VAPE-Z27
5
HTELGTH
Heating Element Length
DESIGN PARAMETER TESTING
2.97
mm
2.97
2.97
mm
1
6
TOB09
PT
VAPE-Z27
6
HTEDIAM
Heating Element Diameter
DESIGN PARAMETER TESTING
3.05
mm
3.05
3.05
mm
1
7
TOB09
PT
VAPE-Z27
7
HTELRST
Heating Element Resistance
DESIGN PARAMETER TESTING
0.77
ohm
0.77
0.77
ohm
1
8
TOB09
PT
VAPE-Z27
8
HTELRNG
Heating Element Range
DESIGN PARAMETER TESTING
174
C
174
174
C
1
9
TOB09
PT
VAPE-Z27
9
HTELCFG
Heating Element Configuration
DESIGN PARAMETER TESTING
SPIRAL
SPIRAL
SPIRAL
1
10
TOB09
PT
VAPE-Z27
10
BTVLTORG
Battery Voltage Operating Range
DESIGN PARAMETER TESTING
4.6
V
4.6
4.6
V
1
11
TOB09
PT
VAPE-Z27
11
BTCRTORG
Battery Current Operating Range
DESIGN PARAMETER TESTING
997
mAh
997
997
mAh
1
12
TOB09
PT
VAPE-Z27
12
BATCAPC
Battery Capacity
DESIGN PARAMETER TESTING
1112
mAh
1112
1112
mAh
1
13
TOB09
PT
VAPE-Z27
13
BATNOMV
Battery Nominal Voltage
DESIGN PARAMETER TESTING
4.18
V
4.18
4.18
V
1
14
TOB09
PT
VAPE-Z27
14
BTCRTRT
Battery Current Rating
DESIGN PARAMETER TESTING
2488
mA
2488
2488
mA
1
15
TOB09
PT
VAPE-Z27
15
BTCHTPL
Battery Charging Temperature Limits
DESIGN PARAMETER TESTING
198
C
198
198
C
1
16
TOB09
PT
VAPE-Z27
16
BTDCTMPL
Battery Discharge Temperature Limits
DESIGN PARAMETER TESTING
19
C
19
19
C
1
17
TOB09
PT
VAPE-Z27
17
BTENDCV
Battery End of Discharge Voltage
DESIGN PARAMETER TESTING
3.03
V
3.03
3.03
V
1
18
TOB09
PT
VAPE-Z27
18
BTMXCHC
Battery Maximum Charging Current
DESIGN PARAMETER TESTING
23.5
mA
23.5
23.5
mA
1
19
TOB09
PT
VAPE-Z27
19
BTMXDCC
Battery Maximum Discharging Current
DESIGN PARAMETER TESTING
2696
mA
2696
2696
mA
1
20
TOB09
PT
VAPE-Z27
20
BTULCHV
Battery Upper Limits Charging Voltage
DESIGN PARAMETER TESTING
4.21
V
4.21
4.21
V
1
21
TOB09
PT
VAPE-Z27
21
PDUVOR
PDU Voltage Operating Range
DESIGN PARAMETER TESTING
3.65
V
3.65
3.65
V
1
22
TOB09
PT
VAPE-Z27
22
PDUCOR
PDU Current Operating Range
DESIGN PARAMETER TESTING
1202
mA
1202
1202
mA
1
23
TOB09
PT
VAPE-Z27
23
PDUTCTOF
PDU Temperature Cut-off
DESIGN PARAMETER TESTING
69.9
C
69.9
69.9
C
1
24
TOB09
PT
VAPE-Z27
24
AIRFLRT
Airflow Rate
DESIGN PARAMETER TESTING
727
L/min
727
727
L/min
1
25
TOB09
PT
VAPE-Z27
25
PDUCRCOF
PDU Current Cut-off
DESIGN PARAMETER TESTING
34.8
mA
34.8
34.8
mA
1
26
TOB09
PT
VAPE-Z27
26
INHAERT
Inhaled Aerosol Temperature
DESIGN PARAMETER TESTING
36.9
C
36.9
36.9
C
1
27
TOB09
PT
VAPE-Z27
27
VENTLTOT
Total Ventilation
DESIGN PARAMETER TESTING
51
%
51
51
%
1
28
TOB09
PT
VAPE-Z27
28
ELQDVISC
E-Liquid Viscosity
Test performed at 20 degrees Celsius
DESIGN PARAMETER TESTING
496
mPa/s
496
496
mPa/s
1
29
TOB09
PT
VAPE-Z27
29
ELQDVOL
E-liquid Volume
DESIGN PARAMETER TESTING
60.1
mL
60.1
60.1
mL
1
30
TOB09
PT
VAPE-Z27
30
PNUMCNC
Particle Number Concentration
DESIGN PARAMETER TESTING
511
/cm3
511
511
/cm3
1
31
TOB09
PT
VAPE-Z27
31
CTMDDIAM
Count Median Diameter
DESIGN PARAMETER TESTING
202
nm
202
202
nm
1
32
TOB09
PT
VAPE-Z27
32
PM2.5
Particulate Matter 2.5
DESIGN PARAMETER TESTING
24.4
ug/m3
24.4
24.4
ug/m3
1
$warningHtml
Example
The following example illustrates the representation of a smokeless tobacco product's (portioned snus) identifiers and descriptors using the TO domain. Note that this example uses TOSCAT to emphasize and differentiate the 2 distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors.
to.xpt
to.xpt
Row
STUDYID
DOMAIN
SPTOBID
TOSEQ
TOPARMCD
TOPARM
TOCAT
TOSCAT
TOVAL
TOVALU
1
TOB17
TO
SNUS-77
1
TBPRDCAT
Tobacco Product Category
NEW PRODUCT
PRODUCT IDENTIFIER
Smokeless Tobacco Products
2
TOB17
TO
SNUS-77
2
TBPRSCAT
Tobacco Product Subcategory
NEW PRODUCT
PRODUCT IDENTIFIER
Portioned Snus
3
TOB17
TO
SNUS-77
3
MANUF
Manufacturer
NEW PRODUCT
PRODUCT IDENTIFIER
Joes Smokeless
4
TOB17
TO
SNUS-77
4
TRADENAM
Trade Name
NEW PRODUCT
PRODUCT IDENTIFIER
Happy Dog Snus
5
TOB17
TO
SNUS-77
5
PACKTYP
Package Type
NEW PRODUCT
PRODUCT DESCRIPTOR
Plastic Can with Lid
6
TOB17
TO
SNUS-77
6
PACKQUAN
Package Quantity
NEW PRODUCT
PRODUCT DESCRIPTOR
24
g
7
TOB17
TO
SNUS-77
7
PRTMASS
Portion Mass
NEW PRODUCT
PRODUCT DESCRIPTOR
1
g
8
TOB17
TO
SNUS-77
8
PORTCONT
Portion count
NEW PRODUCT
PRODUCT DESCRIPTOR
24
9
TOB17
TO
SNUS-77
9
PRTLENG
Portion length
NEW PRODUCT
PRODUCT DESCRIPTOR
30
mm
10
TOB17
TO
SNUS-77
10
PRTWDTH
Portion width
NEW PRODUCT
PRODUCT DESCRIPTOR
10
mm
11
TOB17
TO
SNUS-77
11
PRTTHICK
Portion thickness
NEW PRODUCT
PRODUCT DESCRIPTOR
5
mm
12
TOB17
TO
SNUS-77
12
CHARFLAV
Characterizing Flavor
NEW PRODUCT
PRODUCT DESCRIPTOR
Flavored
$warningHtml
The manufacturing parameter specifications of the portioned snus tobacco product as intended for use are represented in the PD domain. The following example shows the target, minimum, and maximum values associated with each of 10 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.
pd.xpt
pd.xpt
Row
STUDYID
DOMAIN
SPTOBID
PDSEQ
PDPARMCD
PDPARM
PDVALTRG
PDVALMIN
PDVALMAX
PDVALU
1
TOB17
PD
SNUS-77
1
TOCUTSIZ
Tobacco Cut Size
70
65
75
cuts/in
2
TOB17
PD
SNUS-77
1
TOPRTSIZ
Tobacco Particle Size
70
65
75
mm
3
TOB17
PD
SNUS-77
2
TOMOISTR
Tobacco Moisture
32.2
31
34
%
4
TOB17
PD
SNUS-77
3
PRTLENG
Portion Length
38
36.5
39.5
mm
5
TOB17
PD
SNUS-77
4
PRTWDTH
Portion Width
16
15
17
mm
6
TOB17
PD
SNUS-77
5
PRTMASS
Portion Mass
1000
900
1100
mg
7
TOB17
PD
SNUS-77
6
PRTTHICK
Portion Material Thickness
0.06
0.055
0.065
mm
8
TOB17
PD
SNUS-77
7
PRTMWGT
Pouch Material Basis Weight
16
15
17
g/m2
9
TOB17
PD
SNUS-77
8
PRTMPOR
Pouch Material Porosity
1850
1600
2200
L/m2/s
10
TOB17
PD
SNUS-77
9
NICTDSRT
Nicotine Dissolution Rate
15
5
22
%/min
$warningHtml
Finally, the PT domain is used to represent the actual results of testing the manufactured portioned snus product for conformance to the tobacco product design parameters shown in PD. PTCAT is a Required variable and is set to "DESIGN PARAMETER TESTING" for all records here. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only 1 replicate per parameter is shown. Note that PTREPNUM (repetition number) = 1 for all rows.