In this study, subjects were randomized to either nicotine replacement patches or ENDs device which used e nicotine liquid. In order to maintain the blind, subjects used both the nicotine replacement patches and the ENDS device. Subjects were requested not to smoke, but the number of regular cigarettes used were collected. Subject were seen every day for 15 days. The nicotine patch was applied at rotating sites, and the ENDS cartridge was replaced every day. The cartridge was weight when dispended and upon return. On days, 1, 5, 10 subjects remained in the clinic for 4 hours for collection of biomarkers. On these days, a new ENDS cartridge device was inserted and then used for 10 minutes, and then not used for 4 hours. A new cartridge was insert at the end of 4 hours. The patch was applied prior to using the ENDS device on these days.
The SU domain was used to represent the number of cigarettes used, but is not shown.
In this study, the weight of the contents in the cartridges were tracked. A Product Accountability (DA) domain was submitted to represent dispensed and returned weights of the cartridge each day. Each cartridge had a uniquely assigned number. The sponsor used DAREFID that appeared on the label to identify the cartridge
da.xpt
xx.xpt
Row
STUDYID
DOMAIN
USUBJID
DASEQ
DAREFID
DATESTCD
DATEST
DACAT
DASCAT
DAORRES
DAORRESU
DASTRESC
DASTRESN
DASTRESU
DASTAT
DAREASND
VISITNUM
DADTC
1
ABC
DA
ABC-01001
1
CRT8754
DISPAMT
Dispensed Amount
STUDY PRODUCT
E-LIQUID
25
g
25
25
g
1
2004-06-26
2
ABC
DA
ABC-01001
2
CRT8768
DISPAMT
Dispensed Amount
STUDY PRODUCT
E-LIQUID
25
g
25
25
g
1
2004-06-26
3
ABC
DA
ABC-01001
3
CRT8769
DISPAMT
Dispensed Amount
STUDY PRODUCT
E-LIQUID
25
g
25
25
g
1
2004-06-26
4
ABC
DA
ABC-01001
4
CRT8754
RETAMT
Returned Amount
STUDY PRODUCT
E-LIQUID
NOT DONE
Subject forgot to return the cartridge
2020-07-06
5
ABC
DA
ABC-01001
5
CRT8768
RETAMT
Returned Amount
STUDY PRODUCT
E-LIQUID
24
g
24
24
g
2
2020-07-06
6
ABC
DA
ABC-01001
6
CRT8769
RETAMT
Returned Amount
STUDY PRODUCT
E-LIQUID
10
g
10
10
g
2
2020-07-06
7
ABC
DA
ABC-01001
7
CRT9756
DISPAMT
Dispensed Amount
STUDY PRODUCT
E-LIQUID
25
g
25
25
g
2
2020-07-06
8
ABC
DA
ABC-01001
8
CRT9756
RETAMT
Returned Amount
STUDY PRODUCT
E-LIQUID
14
g
14
143
g
3
2020-07-10
9
ABC
DA
ABC-01001
9
CRT8754
RETAMT
Returned Amount
STUDY PRODUCT
E-LIQUID
10
g
10
10
g
3
2020-07-10
10
ABC
DA
ABC-01001
10
Dispensed Amount
STUDY PRODUCT
PAtCH
7
$warningHtml
EC was used to represent the collected exposure data since a double dummy design was used. The EX domain was used to represent the subject's exposure to the product containing nicotine.