TOBA-677 - Getting issue details... STATUS
TIG v1.0 Metadata Check for SDTM Domain Specification Table Beta 3.2
Metadata check macro is applied and detected no issues. This notice is provided as a visual reminder. It will be removed during final publication. Release Notes
Variable Name | Variable Label | Type | Controlled Terms, Codelist, or Format | Role | CDISC Notes | Core |
---|---|---|---|---|---|---|
STUDYID | Study Identifier | Char | Identifier | Unique identifier for a study. | Req | |
DOMAIN | Domain Abbreviation | Char | EM | Identifier | Two-character abbreviation for the domain. | Req |
USUBJID | Unique Subject Identifier | Char | Identifier | Identifier used to uniquely identify a subject across all studies for all applications or submissions involving the product. Permissible rather than required because events may happen to or with a tobacco product device that do not involve subjects, and may even be before the tobacco product device was in contact with a subject. Should be used when the malfunction is associated with a subject's use or possession of the tobacco product device. | Perm | |
SPTOBID | Applicant-Defined Tobacco Product ID | Char | Identifier | Identifier used to uniquely identify a tobacco product across all studies for all applications/submissions involving the product. | Req | |
EMSEQ | Device Events Sequence Number | Num | Identifier | Sequence Number given to ensure uniqueness of records. | Req | |
EMSPID | Applicant-Defined Identifier | Char | Identifier | Applicant-defined reference number. Perhaps defined in the applicant's operational database. Note that it does not have to be numeric. | Perm | |
EMTERM | Reported Term for Device Event | Char | Topic | Verbatim name of the observed event. Examples: "Battery malfunction", "Overheating". | Req | |
EMMODIFY | Modified Device Event Name | Char | Synonym Qualifier | The modified text for EMTERM. If EMTERM is modified, then the modified text is placed here. | Perm | |
EMDECOD | Device Events Dictionary-Derived Term | Char | Synonym Qualifier | Dictionary-derived text description of EMTERM or EMMODIFY. Note: CDISC does not prescribe what standardized or dictionary-derived text should be used. The name and version of the dictionary used to map terms must be provided to reviewers. | Perm | |
EMCAT | Category of Device Event | Char | Grouping Qualifier | Used to define a categorization level for events. For example, "MALFUNCTION" vs. "CALIBRATION". | Perm | |
EMSCAT | Subcategory of Device Event | Char | Grouping Qualifier | Used to define a further category level for events. | Perm | |
EMPRESP | Pre-Specified Device Event | Char | (NY) | Record Qualifier | Used to indicate whether (Y/null) information about a specific event was solicited on the CRF. For example, EMTERM could contain a list of malfunctions that are being specifically evaluated. EMPRESP would identify those (Y), whereas any spontaneous events would have EMPRESP null. | Perm |
EMOCCUR | Device Event Occurrence | Char | (NY) | Record Qualifier | When information about specific events is solicited, EMOCCUR is used to indicate whether or not (Y/N) a particular pre-specified event occurred. Values are null for events not specifically solicited. | Perm |
EMSTAT | Device Event Collection Status | Char | (ND) | Record Qualifier | The status indicates that the pre-specified question was not answered. For example, if equipment operation requires checking, such as checking an event log to detect events. Capturing that the checks were not completed may be relevant to interpreting the study data. | Perm |
EMREASND | Reason Device Event Not Collected | Char | Record Qualifier | Reason EMSTAT was "NOT DONE". This variable should only be used if there are pre-specified events. | Perm | |
EMSEV | Device Event Severity | Char | Record Qualifier | Describes the severity of the event, (e.g, the severity of a malfunction). | Perm | |
EMACNDEV | Action Taken with Device | Char | Record Qualifier | Describes action taken with respect to the tobacco product device. Action Taken may include tobacco product device replacement, battery replacement, etc. | Perm | |
EMPATT | Pattern of Device Event | Char | Record Qualifier | A characterization of the temporal pattern of occurrences of the tobacco product device event or malfunction. | Perm | |
VISITNUM | Visit Number | Num | Timing | Clinical encounter number. Numeric version of VISIT, used for sorting. | Perm | |
VISIT | Visit Name | Char | Timing | Protocol-defined description of clinical encounter. May be used in addition to VISITNUM and/or VISITDY. | Perm | |
VISITDY | Planned Study Day of Visit | Num | Timing | Planned study day of the visit based upon RFSTDTC in Demographics. This value is usually derived. | Perm | |
EMDTC | Date of Device Event Data Collection | Char | ISO 8601 datetime or interval | Timing | Date the tobacco product device event information was collected. This may be reported if the event (e.g., malfunction) is discovered on a different date from the event. | Perm |
EMSTDTC | Start Date/Time of Device Event | Char | ISO 8601 datetime or interval | Timing | Start date/time of the tobacco product device event. If the event happened at a single point in time, EMSTDTC is used. | Perm |
EMENDTC | End Date/Time of Device Event | Char | ISO 8601 datetime or interval | Timing | End date/time of the tobacco product device event. If an event lasted over a period of time, EMENDTC can be used to capture the end date/time. | Perm |
EMDY | Study Day of Start of Tracking Event | Num | Timing | Study day of tobacco product device event observation, measured as integer days. Algorithm for calculations must be relative to the applicant-defined RFSTDTC variable in Demographics. | Perm | |
EMSTDY | Study Day of Device Event Start | Num | Timing | Study day of start of tobacco product device event, measured as integer days. Algorithm for calculations must be relative to the applicant-defined RFSTDTC variable in Demographics. | Perm | |
EMENDY | Study Day of Device Event End | Num | Timing | Study day of end of tobacco product device event, measured as integer days. Algorithm for calculations must be relative to the applicant-defined RFENDTC variable in Demographics. | Perm |