Variable Name

Variable Label

Type

Controlled Terms, Codelist, or Format

Role

CDISC Notes

Core

STUDYID

Study Identifier

Char


Identifier

Unique identifier for a study.

Req

DOMAIN

Domain Abbreviation

Char

GT

Identifier

Two-character abbreviation for the domain.

Req

GTSEQ

Sequence Number

Num


Identifier

The sequence number must be unique for each record within a domain.

Sequence number given to ensure uniqueness of records within a domain. May be any valid number.

Req

GTREFID

Reference IDChar
Identifier

A sequence of characters used to uniquely identify a source of information (e.g., lab specimen, petri dish, flask, well, group of petri dishes, group of flasks, an entire assay).

Req

GTTESTCD

Lab Test or Examination Short Name

Char

(GTTESTCD) TOBA-657 - Getting issue details... STATUS

Topic

Short name of the measurement, test, or examination described in GTTEST. It can be used as a column name when converting a dataset from a vertical to a horizontal format. The value in GTTESTCD cannot be longer than 8 characters, nor can it start with a number (e.g., "1TEST" is not valid). GTTESTCD cannot contain characters other than letters, numbers, or underscores. Examples: RVERT, CYTOTOX.

Req

GTTEST

Lab Test or Examination Name

Char

(GTTEST)

Synonym Qualifier

Long name for GTTESTCD. The value in GTTEST cannot be longer than 40 characters. Examples: Revertants, Cytotoxicity.

Req

GTORRES

Result or Findings as Collected

Char


Result Qualifier

Result of the measurement or finding as originally received or collected.

Exp

GTORRESU

Unit of the Original Result

Char

(UNIT)

Variable Qualifier

The unit for the original result. The unit of the original result should be mapped to a synonymous unit on the Controlled Terminology list.

Exp

GTCELLEV

Number of Cells Evaluated

Num


Result Qualifier

The number of cells evaluated.

Perm

GTCOLSRT

Collected Summary Result Type

Char

(COLSTYP)

Variable Qualifier

Used to indicate the type of collected summary result. TOBA-492 - Getting issue details... STATUS For example, MAXIMUM, MINIMUM, and MEAN.

Perm

GTSTRESC

Standardized Result in Character Format

Char


Result Qualifier

Contains the result value for all findings, copied or derived from GTORRES in a standard format or standard units. GTSTRESC should store all results or findings in character format; if results are numeric, they should also be stored in numeric format in GTSTRESN. For example, if a test has results NONE, NEG, and NEGATIVE in GTORRES and these results effectively have the same meaning, they could be represented in standard format in GTSTRESC as NEGATIVE. For other examples, see general assumptions.

Exp

GTSTRESN

Standardized Result in Numeric Format

Num


Result Qualifier

Used for numeric results or findings in standard format; contains the numeric form of GTSTRESC. GTSTRESN should store all numeric test results or findings.

Exp

GTSTRESU

Unit of the Standardized Result

Char

(UNIT)

Variable Qualifier

Standardized unit used for GTSTRESC, GTSTRESN, GTSTRLO, and GTSTRHI.

Exp

GTSTAT

Completion Status

Char

(ND)

Record Qualifier

Used to indicate when a test is not done or result is missing. Should be null if a result exists in GTORRES.

Perm

GTREASND

Reason Not Done

Char


Record Qualifier

Describes why GTSTAT is NOT DONE, such as BROKEN EQUIPMENT or SPECIMEN LOST.

Perm

GTSPCCND

Specimen Condition

Char

(SPECCOND)

Record Qualifier

Free or standardized text describing the condition of the specimen. Example: PRECIPITATION PRESENT, CONTAMINATED, etc. If multiple conditions are present on a sample, concatenate the values with a semicolon and no spaces as a separator.

Perm

GTSPCUFL

Specimen Usability for the Test

Char

(NY)

Record Qualifier

Describes the usability of the specimen for the test. Should be N if the specimen is not usable; otherwise it should be null.

Perm

GTMETHOD

Method of Test or Examination

Char


Record Qualifier

Method of the test or examination. Examples: MANUALLY COUNTED, INSTRUMENT COUNTED.

Perm TOBA-503 - Getting issue details... STATUS

GTRUNID

Run ID

Char


Record Qualifier

A sequence of characters used to uniquely identify a particular run of a test on a particular batch of samples.

Perm

GTEXCLFL

Exclusion Flag

Char

(NY)

Record Qualifier

Y if the result should be excluded from all calculations, otherwise null.

Perm

GTREASEX

Reason for Exclusion

Char


Record Qualifier

The reason the result should be excluded from all calculations. Used only when GTEXCLFL is Y.

Perm

GTDTC

Date/Time of Collection

Char

ISO 8601 datetime or interval

Timing

The date or date and time of the assessment or the specimen or data collection, TOBA-449 - Getting issue details... STATUS represented in a standardized character format. For an Ames test, this is the date the bacterial culture is plated.