The PR dataset shows the procedure of cardiac magnetic resonance imaging using the device associated with SPDEVID ABC001 and the PRREFID of 12345678. This information shows what CMR device is used for the procedure and the accession number or procedure reference identifier associated with the specific procedure for USUBJID 301. The SPDEVID variable is used to relate records by the device (in this case, the CMR machine). The Device Identifier (DI) dataset holds the device information details, the Device Properties (DO) dataset holds characteristics of the device that do not vary over the between subjects. The Device-In-Use (DU) dataset holds settings that are set on a device when it is used and may vary between participants.
pr.xpt
pr.xpt
Row
STUDYID
DOMAIN
USUBJID
SPDEVID
PRSEQ
PRREFID
PRLNKID
PRTRT
PRSTDTC
1
DMD-RT
PR
301
ABC001
1
12345678
04
CARDIAC MAGNETIC RESONANCE IMAGING
2023-08-01
$warningHtml
The Cardiovascular System Findings (CV) dataset contains physiological and morphological findings related to the cardiovascular system so it holds the assessments from the parametric mapping. The CV dataset below shows how to represent longitudinal relaxation time, transverse relaxation time and extracellular volume findings from CMR. The timing of the contrast specificity is noted using the CVTPT to note if the CVTEST was done before or after contrast. CVTPTREF associates the timepoints in CVTPT with "contrast administration." In the example below, row 9 represents and unreadable CMR using CVSTAT variable to show the reading was "NOT DONE" and the CVREASND variable to show the reason the procedure was not done, or in this case the result not provided which was a "Non-Evaluable" image . A similar approach may be used if there is a desire to record that the CMR was not obtained at the specific visit (omitting the poor quality information) and why in the dataset records.
Rows 1-6:
Show the T1 Longitudinal Relaxation Time, and the T2 Transverse Relaxation Time, (Native T1 Mapping) for different segments of the heart prior to contrast for CMR.
Rows 7-8:
Show the T1 Longitudinal Relaxation Time, Native T1 Mapping, and Extracellular volume for different segments of the heart after contrast for CMR.
Row 9:
Shows participant 302 had a CMR procedure that was unreadable, CVREASND = "NON-EVALUABLE". This is denoted by CVTESTCD of CVALL for "CARDIOVASCULAR SYSTEM FINDINGS with the METHOD of "CARDIAC MAGNETIC RESONANCE IMAGING".
Row 10:
Shows participant 303 did not have a CMR procedure because they were unable to place an intravenous access line, CVREASND = "UNABLE TO PLACE INTRAVENOUS LINE".
cv.xpt
cv.xpt
Row
STUDYID
DOMAIN
USUBJID
CVSEQ
CVTESTCD
CVTEST
CVORRES
CVORRESU
CVSTRESC
CVSTRESN
CVSTRESU
CVSTAT
CVREASND
CVLOC
CVMETHOD
CVLOBFXL
VISITNUM
VISIT
CVTPT
CVTPTREF
CVDTC
CVOIQ
1
DMD-RT
CV
301
1
T1
LONGITUDINAL RELAXATION TIME (T1 TIME)
1315
ms
1315
1315
ms
LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
BEFORE
CONTRAST ADMINISTRATION
2023-08-01
EVALUABLE IMAGE
2
DMD-RT
CV
301
2
T1
LONGITUDINAL RELAXATION TIME (T1 TIME)
1166
ms
1166
1166
ms
LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
BEFORE
CONTRAST ADMINISTRATION
2023-08-01
EVALUABLE IMAGE
3
DMD-RT
CV
301
3
T1
LONGITUDINAL RELAXATION TIME (T1 TIME)
980
ms
980
980
ms
LEFT VENTRICULAR BASAL INFERIOR SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
BEFORE
CONTRAST ADMINISTRATION
2023-08-01
EVALUABLE IMAGE
4
DMD-RT
CV
301
4
T2
TRANSVERSE RELAXATION TIME (T2 TIME)
45
ms
45
45
ms
LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
BEFORE
CONTRAST ADMINISTRATION
2023-08-01
EVALUABLE IMAGE
5
DMD-RT
CV
301
5
T2
TRANSVERSE RELAXATION TIME (T2 TIME)
40
ms
40
40
ms
LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
BEFORE
CONTRAST ADMINISTRATION
2023-08-01
EVALUABLE IMAGE
6
DMD-RT
CV
301
6
T2
TRANSVERSE RELAXATION TIME (T2 TIME)
48
ms
48
48
ms
LEFT VENTRICULAR BASAL INFERIOR SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
BEFORE
CONTRAST ADMINISTRATION
2023-08-01
EVALUABLE IMAGE
7
DMD-RT
CV
301
7
T1
LONGITUDINAL RELAXATION TIME (T1 TIME)
450
ms
450
450
ms
LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
AFTER
CONTRAST ADMINISTRATION
2023-08-01
EVALUABLE IMAGE
8
DMD-RT
CV
301
8
EXTRAVOL
EXTRACELLULAR VOLUME
25
%
25
25
%
LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
AFTER
CONTRAST ADMINISTRATION
2023-08-01
EVALUABLE IMAGE
9
DMD-RT
CV
302
1
CVALL
CARDIOVASCULAR SYSTEM FINDINGS
NOT DONE
NON-EVALUABLE IMAGE
HEART
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
CONTRAST ADMINISTRATION
2023-08-05
NON-EVALUABLE IMAGE
10
DMD-RT
CV
303
1
CVALL
CARDIOVASCULAR SYSTEM FINDINGS
NOT DONE
UNABLE TO PLACE INTRAVENOUS LINE
HEART
CARDIAC MAGNETIC RESONANCE IMAGING
1
SCREENING
CONTRAST ADMINISTRATION
2023-08-05
$warningHtml
CV NSV Metadata
Variable
Label
Type
Role
Origin
CVOIQ
Overall Image Quality
text
Non-standard Record Qualifier
CRF
Dataset Wrapper Debug Message
Please add a row column to your dataset.
The AG dataset shows the Gadolinium based contrast that was used for the procedure. In this example, the researchers did not collect the time of the contrast.
ag.xpt
ag.xpt
Row
STUDYID
DOMAIN
USUBJID
AGSEQ
AGTRT
AGCAT
AGDOSE
AGDOSU
AGDOSFRM
AGROUTE
AGSTDTC
1
DMD-LGE
AG
301
1
Gd-DOTA
CONTRAST AGENT
8
mL
SOLUTION
INTRAVENOUS
2023-08-01
$warningHtml
DI holds the device identifier information that describes the device used to produce the image that was the basis of the interpretation recorded in the CV domain. Characteristics in DI are those necessary to identify each device to the level of granularity necessary for the study (e.g., to the model level if knowing the actual unit is not necessary, to the serial number level if there is a need to distinguish among units).
di.xpt
di.xpt
Row
STUDYID
DOMAIN
SPDEVID
DISEQ
DIPARMCD
DIPARM
DIVAL
1
DMD-LGE
DI
ABC001
1
DEVTYPE
Device Type
CMR Scanner
2
DMD-LGE
DI
ABC001
2
MANUF
Manufacturer
ACME
3
DMD-LGE
DI
ABC001
3
TRADENAM
Trade Name
ACME 64
4
DMD-LGE
DI
ABC001
4
MODEL
Model Number
CMR540
$warningHtml
Fixed properties of devices identified in DI are represented in the DO domain. The sponsor chose to keep the software version constant throughout the study. DO should contain properties that are important for interpreting the data.
do.xpt
do.xpt
Row
STUDYID
DOMAIN
SPDEVID
DOSEQ
DOTESTCD
DOTEST
DOORRES
DOORRESU
1
DMD-LGE
DO
ABC002
1
SFTWRNAM
Software Name
CMRRLXU2
2
DMD-LGE
DO
ABC002
2
SFTWRVER
Software Version
CMRLX.2
3
DMD-LGE
DO
ABC002
3
IMAQDIM
Image Acquisition Dimensionality
3
$warningHtml
Changeable properties and parameters of the devices identified in DI are represented in the DU domain. These settings could be linked to the record in the CV domain by their shared SPDEVID and DTC values. For the sake of brevity, only 1 subject's parameters are shown. For more information on relating records, see SDTMIG v3.4 Section 8.2, Relating Peer Records.
du.xpt
du.xpt
Row
STUDYID
DOMAIN
USUBJID
SPDEVID
DUSEQ
DUREFID
DUTESTCD
DUTEST
DUORRES
DUORRESU
DUSTRESC
DUSTRESN
DUSTRESU
DUDTC
1
DMD-LGE
DU
301
ABC001
1
12345678
ANTPLAN
Anatomical Plane
SAGITTAL
SAGITTAL
2023-08-01
2
DMD-LGE
DU
301
ABC001
2
12345678
PULSSEQ
Pulse Sequence
SPGR
SPGR
2023-08-01
3
DMD-LGE
DU
301
ABC001
3
12345678
FLIPANGL
Flip Angle
50
deg
50
50
deg
2023-08-01
4
DMD-LGE
DU
301
ABC001
4
12345678
INTDISTM
Interslice Distance
1
mm
1
1
mm
2023-08-01
5
DMD-LGE
DU
301
ABC001
5
12345678
STHICK
Slice Thickness
6
mm
6
6
mm
2023-08-01
6
DMD-LGE
DU
301
ABC001
6
12345678
FLDVIEW
Field of View
32X38
cm
32X38
32X38
cm
2023-08-01
7
DMD-LGE
DU
301
ABC001
7
12345678
NUMSLICE
Number of Slices
12
12
12
2023-08-01
8
DMD-LGE
DU
301
ABC001
8
12345678
COILSTR
Coil Strength
1.5
T
1.5
1.5
T
2023-08-01
$warningHtml
The RELREC dataset is used to describe the relationship between 2 or more records in different domains. For more information on relating records see SDTMIG v3.4, Section 8.2.