You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 9 Next »

  1. Is row 4 to delineate between 2D/3D/4D strain analysis LV chamber views?
  2. Question for Jon Neville - does ANMETH fit for the place to put the chamber view ofr the MR visualization?
  3. Would it be better to show one segment across the different dimensional chamber views at 2 or 3 timepoints?  1, 2, 5 yr point - could do one with change and one without change.
  4. Is there a best terminology to use for the dimensions?  check CT, 2D, 3D, 4D OR two-dimensional, three-dimensional, four-dimensional (2D is peak radial strain; 3D is peak circumferential strain, 4D is peak longitudinal strain..... is "peak" assumed or does that need to be there?)
  5. What test is used to measure fibrosis - is it LGE or strain?

-20 is a good result, -10 is a poor result. Could show change over time with first assessment normal, one example could have poor 1 year follow-up and the other can have stable cardiomyopathy disease. Or could just do this.

Rows 1-3:Show circumferential strain with a 3 dimensional chamber view (CVANMETH) of the left ventricular basal anterior segment, left ventricular basal anteroseptal segment, and left ventricular basal inferoseptal segment (CVLOC).
Row 4:? - delete? If yes, shall we delete the 4D in the location of rows 5 & 6?
Rows 5-6:Show circumferential strain with a 4 dimensional chamber view of the left ventricular basal inferoseptal segment and the left ventricular mid inferoseptal segment.

cv.xpt

cv.xpt

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVTESTCD

CVTEST

CVORRES

CVORRESU

CVSTRESC

CVSTRESN

CVSTRESU

CVLOC

CVMETHOD

CVANMETH

CVLOBFXL

VISITNUM

VISIT

CVDTC

1DMD-CLSCV4011CFSTRAINCIRCUMFERENTIAL STRAIN

-9

%

-9

-9%

LEFT VENTRICULAR BASAL ANTERIOR SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING3D -3 chamber view
1SCREENING2023-09-01
2DMD-CLSCV4012CFSTRAINCIRCUMFERENTIAL STRAIN

-12

%

-12

-12%LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING3D - 30chamber view
1SCREENING2023-09-01
3DMD-CLSCV4013CFSTRAINCIRCUMFERENTIAL STRAIN

-12

%

-12

-12%LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING3D - 3 chamber view
1SCREENING2023-09-01
4DMD-CLSCV4014LNGSTRAINLONGITUDINAL STRAIN






4 CHAMBER

CARDIAC MAGNETIC RESONANCE IMAGING4D - 4 chamber view
1SCREENING2023-09-01
5DMD-CLSCV4015LNGSTRAINLONGITUDINAL STRAIN

-14

%

-14

-14%LEFT VENTRICULAR 4 CHAMBER BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING4D - 4 chamber view
1SCREENING2023-09-01
6DMD-CLSCV4016LNGSTRAINLONGITUDINAL STRAIN

-13

%

-13

-13%LEFT VENTRICULAR MID INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING

1SCREENING2023-09-01
$warningHtml

Dataset Wrapper Debug Message

Please add a row column to your dataset.