This example illustrates the representation of a cigarette product's identifiers and descriptors using the TO domain. Note that this example uses TOSCAT (Subcategory of Tobacco Prod ID Element, a permissible variable) to emphasize and differentiate the 2 distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors.
to.xpt
to.xpt
Row
STUDYID
DOMAIN
SPTOBID
TOSEQ
TOPARMCD
TOPARM
TOCAT
TOSCAT
TOVAL
TOVALU
1
TOB07
TO
CIG01a
1
TBPRDCAT
Tobacco Product Category
NEW PRODUCT
PRODUCT IDENTIFIER
Cigarette
2
TOB07
TO
CIG01a
2
TBPRSCAT
Tobacco Product Subcategory
NEW PRODUCT
PRODUCT IDENTIFIER
Filtered, Combusted
3
TOB07
TO
CIG01a
3
MANUF
Manufacturer
NEW PRODUCT
PRODUCT IDENTIFIER
Joes Cigs USA
4
TOB07
TO
CIG01a
4
TRADENAM
Trade Name
NEW PRODUCT
PRODUCT IDENTIFIER
Treetop Menthol King Size
5
TOB07
TO
CIG01a
5
PACKTYP
Package Type
NEW PRODUCT
PRODUCT DESCRIPTOR
HARD PACK
6
TOB07
TO
CIG01a
6
PRDQUAN
Product Quantity
NEW PRODUCT
PRODUCT DESCRIPTOR
20
CIGARETTE
7
TOB07
TO
CIG01a
7
LENGTH
Length
NEW PRODUCT
PRODUCT DESCRIPTOR
86.0
mm
8
TOB07
TO
CIG01a
8
CIRCUMF
Circumference
NEW PRODUCT
PRODUCT DESCRIPTOR
26.0
mm
9
TOB07
TO
CIG01a
9
VENTLTN
Ventilation
NEW PRODUCT
PRODUCT DESCRIPTOR
10.0
%
10
TOB07
TO
CIG01a
10
CHARFLAV
Characterizing Flavor
NEW PRODUCT
PRODUCT DESCRIPTOR
MENTHOL
$warningHtml
The manufacturing parameter specifications of the cigarette tobacco product as intended for use are represented in the Product Design Parameters (PD) domain The following example shows the target, minimum, and maximum values associated with each of 23 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.
Note the use of the variable IGDCMPID (Ingredient or Component Identifier) in rows 5-6. This tobacco product had 2 tobacco ingredients with 2 different tobacco cut sizes. IGDCMPID identifies to which tobacco ingredient the cut size applies. IGDCMPID originates in the IT (Tobacco Ingredients) and IN (Non-Tobacco Ingredients) domains. See Section 3.1.3.1, Ingredients and Additives, for more information.
pd.xpt
pd.xpt
Row
STUDYID
DOMAIN
SPTOBID
IGDCMPID
PDSEQ
PDPARMCD
PDPARM
PDVALTRG
PDVALMIN
PDVALMAX
PDVALU
1
TOB07
PD
CIG01a
1
LENGTH
Length
84
83.5
84.5
mm
2
TOB07
PD
CIG01a
2
CIRCUMF
Circumference
24.8
24.6
25
mm
3
TOB07
PD
CIG01a
3
TBFLMASS
Tobacco Filler Mass
783
753
814
mg
4
TOB07
PD
CIG01a
4
MOISTURE
Moisture
13
12
14
%
5
TOB07
PD
CIG01a
Burley tobacco
5
TOCUTSIZ
Tobacco Cut Size
22
20
24
cuts/in
6
TOB07
PD
CIG01a
Reconstituted tobacco
6
TOCUTSIZ
Tobacco Cut Size
27
25
29
mm
7
TOB07
PD
CIG01a
7
FLTRVENT
Filter Ventilation
30
23
37
%
8
TOB07
PD
CIG01a
8
TPNPLGTH
Tipping Paper Length
31
30
32
mm
9
TOB07
PD
CIG01a
9
CIGBPPOR
Cigarette Base Paper Porosity
50
45
55
Cu
10
TOB07
PD
CIG01a
10
CBPPERM
Cigarette Base Paper Permeability
50
45
55
Cu
11
TOB07
PD
CIG01a
11
CBPPOR
Cigarette Paper Band Porosity
10
0.2
13
Cu
12
TOB07
PD
CIG01a
12
CPBPERM
Cigarette Paper Band Permeability
10
0.2
13
Cu
13
TOB07
PD
CIG01a
13
CPBDIFF
Cigarette Paper Band Diffusivity
0.05
0.001
0.100
cm2/s
14
TOB07
PD
CIG01a
14
CPBWID
Cigarette Paper Band Width
7
6.7
7.3
mm
15
TOB07
PD
CIG01a
15
CPBSPC
Cigarette Paper Band Space
20
19.8
20.2
mm
16
TOB07
PD
CIG01a
16
FLTREFF
Filter Efficiency
30
25
35
%
17
TOB07
PD
CIG01a
17
DPF
Denier Per Filament
4
3.6
4.4
g/9000m
18
TOB07
PD
CIG01a
18
TDENIER
Total Denier
30000
29100
30900
g/9000m
19
TOB07
PD
CIG01a
19
FLTRDEN
Filter Density
0.1234
0.105
0.1419
g/cm3
20
TOB07
PD
CIG01a
20
FLTRLGTH
Filter Length
25
24.5
25.5
mm
21
TOB07
PD
CIG01a
21
FLTPRDRP
Filter Pressure Drop
60
51
69
mm H2O
22
TOB07
PD
CIG01a
22
TORODDEN
Tobacco Rod Density
0.2678
0.2437
0.2919
g/cm3
23
TOB07
PD
CIG01a
23
CIGPLGTH
Cigarette Paper Length
53
52
54
mm
$warningHtml
Finally, the Tobacco Product Testing (PT) domain is used to represent the actual results of testing the manufactured cigarette product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a Required variable and is set to "DESIGN PARAMETER TESTING" for all records here. As described in the PD example, IGDCMPID is also used here to differentiate 2 records of the same test performed on each of 2 different types of tobacco that are ingredients of the tobacco product. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only 1 replicate per parameter is shown. Note that PTREPNUM (repetition number) = 1 for all rows.
pt.xpt
pt.xpt
Row
STUDYID
DOMAIN
SPTOBID
IGDCMPID
PTSEQ
PTTESTCD
PTTEST
PTCAT
PTORRES
PTORRESU
PTSTRESC
PTSTRESN
PTSTRESU
PTMETHOD
PTREPNUM
1
TOB07
PT
CIG01a
1
LENGTH
Length
DESIGN PARAMETER TESTING
83.9
mm
83.9
83.9
mm
1
2
TOB07
PT
CIG01a
2
CIRCUMF
Circumference
DESIGN PARAMETER TESTING
24.9
mm
24.9
24.9
mm
1
3
TOB07
PT
CIG01a
3
TBFLMASS
Tobacco Filler Mass
DESIGN PARAMETER TESTING
779
mg
779
779
mg
1
4
TOB07
PT
CIG01a
4
MOISTURE
Moisture
DESIGN PARAMETER TESTING
13.1
%
13.1
13.1
%
1
5
TOB07
PT
CIG01a
Burley tobacco
5
TOCUTSIZ
Tobacco Cut Size
DESIGN PARAMETER TESTING
22
cuts/in
22
22
cuts/in
1
6
TOB07
PT
CIG01a
Reconstituted tobacco
6
TOCUTSIZ
Tobacco Cut Size
DESIGN PARAMETER TESTING
27
mm
27
27
mm
1
7
TOB07
PT
CIG01a
7
FLTRVENT
Filter Ventilation
DESIGN PARAMETER TESTING
35
%
35
35
%
1
8
TOB07
PT
CIG01a
8
TPNPLGTH
Tipping Paper Length
DESIGN PARAMETER TESTING
30
mm
30
30
mm
1
9
TOB07
PT
CIG01a
9
CIGBPPOR
Cigarette Base Paper Porosity
DESIGN PARAMETER TESTING
48
Cu
48
48
Cu
1
10
TOB07
PT
CIG01a
10
CBPPERM
Cigarette Base Paper Permeability
DESIGN PARAMETER TESTING
50
Cu
50
50
Cu
1
11
TOB07
PT
CIG01a
11
CBPPOR
Cigarette Paper Band Porosity
DESIGN PARAMETER TESTING
9.8
Cu
9.8
9.8
Cu
1
12
TOB07
PT
CIG01a
12
CPBPERM
Cigarette Paper Band Permeability
DESIGN PARAMETER TESTING
10
Cu
10
10
Cu
1
13
TOB07
PT
CIG01a
13
CPBDIFF
Cigarette Paper Band Diffusivity
DESIGN PARAMETER TESTING
0.06
cm2/s
0.06
0.06
cm2/s
1
14
TOB07
PT
CIG01a
14
CPBWID
Cigarette Paper Band Width
DESIGN PARAMETER TESTING
7.1
mm
7.1
7.1
mm
1
15
TOB07
PT
CIG01a
15
CPBSPC
Cigarette Paper Band Space
DESIGN PARAMETER TESTING
19.9
mm
19.9
19.9
mm
1
16
TOB07
PT
CIG01a
16
FLTREFF
Filter Efficiency
DESIGN PARAMETER TESTING
28
%
28
28
%
1
17
TOB07
PT
CIG01a
17
DPF
Denier Per Filament
DESIGN PARAMETER TESTING
4.1
4.1
4.1
g/9000m
1
18
TOB07
PT
CIG01a
18
TDENIER
Total Denier
DESIGN PARAMETER TESTING
29900
g/9000m
29900
29900
g/9000m
1
19
TOB07
PT
CIG01a
19
FLTRDEN
Filter Density
DESIGN PARAMETER TESTING
0.1112
g/cm3
0.1112
0.1112
g/cm3
1
20
TOB07
PT
CIG01a
20
FLTRLGTH
Filter Length
DESIGN PARAMETER TESTING
25
mm
25
25
mm
1
21
TOB07
PT
CIG01a
21
FLTPRDRP
Filter Pressure Drop
DESIGN PARAMETER TESTING
62
mm H2O
62
62
mm H2O
1
22
TOB07
PT
CIG01a
22
TORODDEN
Tobacco Rod Density
DESIGN PARAMETER TESTING
0.2701
g/cm3
0.2701
0.2701
g/cm3
1
23
TOB07
PT
CIG01a
23
CIGPLGTH
Cigarette Paper Length
DESIGN PARAMETER TESTING
53
mm
53
53
mm
1
$warningHtml
References:
International Organization for Standardization. ISO 9512:2019(en) - Cigarettes — Determination of ventilation — Definitions and measurement principles. ISO; June 2019. Accessed October 15, 2023. https://www.iso.org/obp/ui/#iso:std:iso:9512:ed-3:v1:en
Song M-A, Benowitz NL, Berman M, et al. Cigarette filter ventilation and its relationship to increasing rates of lung adenocarcinoma. J Natl Cancer Inst. 2017;109(12):djx075. https://doi.org/10.1093/jnci/djx075