Tobacco product HPHC testing results are represented in the PT domain. This example assumes testing at a single time point, not serial testing over multiple timepoints as in stability studies. See the Stability Studies section for more information and examples on handling those data.

This example only shows test results for each constituent for one replicate of one sample of one product that was tested (PTREPNUM = 1 for all records). Details of the sampling and testing plan, including the number of samples of the products tested, are determined by the sponsor or by regulatory requirement.  Sponsors would likely have multiple product samples tested in multiple replicates, and those would be distinguished in the dataset by values of PTREPNUM being set to 1 through n, where n = the number of replicates being performed.

Note the use of the PTXFN (external file name) to indicate that the lab methodology was submitted as separate documentation.

Rows 1-17:Show HPHC testing performed in smoke produced by a smoking machine from the tobacco product identified in SPTOBID (CIG01a). Note of the use of SPDEVID as the device identifier for the smoking machine and the use of PTREFID to identify the smoking regimen ( Non-intense regimen). PTSPEC=SMOKE to indicate the specimen type is smoke.
Row 18:Shows one analyte was tested with a different smoking regimen (PTREFID=INTENSE REGIMEN) using the same smoking machine.
Row 19:Shows one analyte was tested in the tobacco filler (PTSPEC). Thus SPDEVID and PTREFID are null.

pt.xpt

pt.xpt

RowSTUDYIDDOMAINSPTOBIDSPDEVIDPTSEQPTREFIDPTCASPTTESTCDPTTESTPTCATPTSCATPTORRESPTORRESUPTSTRESCPTSTRESNPTSTRESUPTXFNPTNAMPTSPECPTREPNUMPTDTC
1TOB07PTCIG01aPUFFMASTER3K1NON-INTENSE REGIMEN75-07-0ACTALDAcetaldehydeHPHC TESTINGHPHC522ug/cigarette522522ug/cigaretteTL001_V5.pdfTPT LABCOSMOKE12022-09-30
2TOB07PTCIG01aPUFFMASTER3K2NON-INTENSE REGIMEN107-02-8ACROLEINAcroleinHPHC TESTINGHPHC43ug/cigarette4343ug/cigaretteTL002_V3.6.pdfTPT LABCOSMOKE12022-09-30
3TOB07PTCIG01aPUFFMASTER3K3NON-INTENSE REGIMEN107-13-1ACRYNTRLAcrylonitrileHPHC TESTINGHPHC7ug/cigarette77ug/cigaretteTL006_V6.pdfTPT LABCOSMOKE12022-09-30
4TOB07PTCIG01aPUFFMASTER3K4NON-INTENSE REGIMEN92-67-1ABP44-AminobiphenylHPHC TESTINGHPHC1.2ng/cigarette1.21.2ng/cigaretteTL008_V3.pdfTPT LABCOSMOKE12022-09-30
5TOB07PTCIG01aPUFFMASTER3K5NON-INTENSE REGIMEN134-32-7AMNPHTH11-AminonaphthaleneHPHC TESTINGHPHC14ng/cigarette1414ng/cigaretteTL003_V1.4.pdfTPT LABCOSMOKE12022-09-30
6TOB07PTCIG01aPUFFMASTER3K6NON-INTENSE REGIMEN134-32-7AMNPHTH22-AminonaphthaleneHPHC TESTINGHPHC8ng/cigarette88ng/cigaretteTL003_V1.4.pdfTPT LABCOSMOKE12022-09-30
7TOB07PTCIG01aPUFFMASTER3K7NON-INTENSE REGIMEN7664-41-7AMMONIAAmmoniaHPHC TESTINGHPHC9ug/cigarette99ug/cigaretteTL020_V4.pdfTPT LABCOSMOKE12022-09-30
8TOB07PTCIG01aPUFFMASTER3K8NON-INTENSE REGIMEN71-43-2BENZENEBenzeneHPHC TESTINGHPHC33ug/cigarette3333ug/cigaretteTL017_V1.1.pdfTPT LABCOSMOKE12022-09-30
9TOB07PTCIG01aPUFFMASTER3K9NON-INTENSE REGIMEN50-32-8BZAPYRBenzo[a]pyreneHPHC TESTINGHPHC6.8ng/cigarette6.86.8ng/cigaretteTL017_V1.1.pdfTPT LABCOSMOKE12022-09-30
10TOB07PTCIG01aPUFFMASTER3K10NON-INTENSE REGIMEN630-08-0CMONOXCarbon MonoxideHPHC TESTINGHPHC10.1mg/cigarette10.110.1mg/cigaretteTL019_V3.pdfTPT LABCOSMOKE12022-09-30
11TOB07PTCIG01aPUFFMASTER3K11NON-INTENSE REGIMEN4170-30-3CROTNALDCrotonaldehydeHPHC TESTINGHPHC11ug/cigarette1111ug/cigaretteTL001_V5.pdfTPT LABCOSMOKE12022-09-30
12TOB07PTCIG01aPUFFMASTER3K12NON-INTENSE REGIMEN50-00-0FORMALDFormaldehydeHPHC TESTINGHPHC27ug/cigarette2727ug/cigaretteTL001_V5.pdfTPT LABCOSMOKE12022-09-30
13TOB07PTCIG01aPUFFMASTER3K13NON-INTENSE REGIMEN78-79-5ISOPRENEIsopreneHPHC TESTINGHPHC320ug/cigarette320320ug/cigaretteTL041_V1.pdfTPT LABCOSMOKE12022-09-30
14TOB07PTCIG01aPUFFMASTER3K14NON-INTENSE REGIMEN1954-11-05NICOTINENicotineHPHC TESTINGHPHC0.721mg/cigarette0.7210.721mg/cigaretteTL007_V2.1.pdfTPT LABCOSMOKE12022-09-30
15TOB07PTCIG01aPUFFMASTER3K15NON-INTENSE REGIMEN64091-91-4NNKNicotine-Derived Nitrosamine KetoneHPHC TESTINGHPHC71ng/cigarette7171ng/cigaretteTL026_V12.2.pdfTPT LABCOSMOKE12022-09-30
16TOB07PTCIG01aPUFFMASTER3K16NON-INTENSE REGIMEN16543-55-8NNNN-NitrosonornicotineHPHC TESTINGHPHC85ng/cigarette8585ng/cigaretteTL026_V12.2.pdfTPT LABCOSMOKE12022-09-30
17TOB07PTCIG01aPUFFMASTER3K17NON-INTENSE REGIMEN108-88-3TOLUENETolueneHPHC TESTINGHPHC53ug/cigarette5353ug/cigaretteTL011_V3.3.pdfTPT LABCOSMOKE12022-09-30
18TOB07PTCIG01aPUFFMASTER3K18INTENSE REGIMEN75-07-0ACTALDAcetaldehydeHPHC TESTINGHPHC1552ug/cigarette15521552ug/cigaretteTL009_V4.3.pdfTPT LABCOSMOKE12022-09-30
19TOB07PTCIG01aPUFFMASTER3K19
7664-41-7AMMONIAAmmoniaHPHC TESTINGHPHC956ug/g956956ug/cigaretteTL016_V1.2.pdfTPT LABCOTOBACCO FILLER12022-09-30
$warningHtml

Dataset Wrapper Debug Message

Please add a row column to your dataset.

The identifying characteristics of the smoking machine are represented in the Device Identifiers reference dataset. DI is the source of the sponsor-defined device ID variable (SPDEVID) used in the PT dataset to indicate the smoking machine used to perform the smoking regimen.

di.xpt

di.xpt

RowSTUDYIDDOMAINSPDEVIDDISEQDIPARMCDDIPARMDIVAL
1TOB07DIPUFFMASTER3K1DEVTYPEDevice TypeSmoking Machine
2TOB07DIPUFFMASTER3K2MANUFManufacturerAcme
3TOB07DIPUFFMASTER3K3TRADENAMTrade NamePuffMaster 3000
$warningHtml
Details of the smoking regimen performed by the smoking machine are represented as device in-use properties (such as settings) of the smoking machine. They are linked to the HPHC testing results in PT above by matching values of PTREFID/DUREFID.
Rows 1-9:Show the parameters of the non-intense smoking regimen.
Rows 8-9:Note the use of PTGRPID to group these records together to indicate that puff pause and puff pause interval are related records. Taken together they tell us that this smoking regimen pauses for 60 seconds every 10 puffs.
Rows 10-18:Show the parameters of the intense smoking regimen.
Rows 17-18:Note the use of PTGRPID to group these records together to indicate that puff pause and puff pause interval are related records. Taken together they tell us that this smoking regimen pauses for 30 seconds every 10 puffs.

du.xpt

du.xpt

Row

STUDYIDDOMAINSPDEVIDDUSEQDUREFIDDUGRPIDDUTESTCDDUTESTDUORRESDUORRESUDUSTRESCDUSTRESNDUSTRESU
1

TOB07

DUPUFFMASTER3K1INTENSE REGIMEN
PUFFPROFPuff ProfileSQUARE
SQUARE

2

TOB07

DUPUFFMASTER3K2INTENSE REGIMEN

PUFFDUR

Puff Duration

1.25

sec

1.25

1.25

sec

3

TOB07

DUPUFFMASTER3K3INTENSE REGIMEN

PUFFINT

Puff Interval

3

PUFF/min

3

3

PUFF/min

4

TOB07

DUPUFFMASTER3K4INTENSE REGIMEN

PUFFBLCK

Puff Block

25

%

25

25

%

5

TOB07

DUPUFFMASTER3K5INTENSE REGIMEN
NUMPUFFTotal Number of Puffs

200

PUFF

200

200

PUFF

6

TOB07

DUPUFFMASTER3K6INTENSE REGIMEN
PUFFVOLPuff Volume

10

mL

10

10

mL

7

TOB07

DUPUFFMASTER3K7INTENSE REGIMEN
PUFFRNGPuff Range

100-200


100-200



8

TOB07

DUPUFFMASTER3K8INTENSE REGIMEN1PUFFPAUSPuff Pause

60

s

60

60

s

9TOB07DUPUFFMASTER3K9INTENSE REGIMEN1PUFFPINTPuff Pause Interval

10

PUFF

10

10

PUFF

10

TOB07

DUPUFFMASTER3K1INTENSE REGIMEN
PUFFPROFPuff ProfileSQUARE
SQUARE

11

TOB07

DUPUFFMASTER3K2INTENSE REGIMEN

PUFFDUR

Puff Duration

1.5

sec

1.5

1.5

sec

12

TOB07

DUPUFFMASTER3K3INTENSE REGIMEN

PUFFINT

Puff Interval

3

PUFF/min

3

3

PUFF/min

13

TOB07

DUPUFFMASTER3K4INTENSE REGIMEN

PUFFBLCK

Puff Block

30

%

30

30

%

14

TOB07

DUPUFFMASTER3K5INTENSE REGIMEN
NUMPUFFTotal Number of Puffs

100

PUFF

100

100

PUFF

15

TOB07

DUPUFFMASTER3K6INTENSE REGIMEN
PUFFVOLPuff Volume

10

mL

10

10

mL

16

TOB07

DUPUFFMASTER3K7INTENSE REGIMEN
PUFFRNGPuff Range

50-150


50-150



17

TOB07

DUPUFFMASTER3K8INTENSE REGIMEN2PUFFPAUSPuff Pause

30

s

30

30

s

18TOB07DUPUFFMASTER3K9INTENSE REGIMEN2PUFFPINTPuff Pause Interval

10

PUFF

10

10

PUFF