The following example illustrates the representation of an ENDS tobacco product's identifiers and descriptors using the TO domain. Note that this example makes use of TOCAT (Category of Tobacco Product ID Element, a permissible variable) to emphasize and differentiate the two distinct types of parameters represented in TO: tobacco product identifiers and tobacco product descriptors.
to.xpt
to.xpt
Row
STUDYID
DOMAIN
SPTOBID
TOSEQ
TOPARMCD
TOPARM
TOCAT
TOVAL
TOVALU
1
TOB09
TO
VAPE-Z27
1
TBPRDCAT
Tobacco Product Category
PRODUCT IDENTIFIER
ENDS (VAPES)
2
TOB09
TO
VAPE-Z27
2
TBPRSCAT
Tobacco Product Subcategory
PRODUCT IDENTIFIER
Closed E-Cigarette
3
TOB09
TO
VAPE-Z27
3
MANUF
Manufacturer
PRODUCT IDENTIFIER
Joes Vapes USA
4
TOB09
TO
VAPE-Z27
4
TRADENAM
Trade Name
PRODUCT IDENTIFIER
Everyday Rich Tobacco
5
TOB09
TO
VAPE-Z27
5
PACKTYP
Package Type
PRODUCT DESCRIPTOR
BOX
6
TOB09
TO
VAPE-Z27
6
PRDQUAN
Product Quantity
PRODUCT DESCRIPTOR
1
E-CIGARETTE
7
TOB09
TO
VAPE-Z27
7
LENGTH
Length
PRODUCT DESCRIPTOR
107.2
mm
8
TOB09
TO
VAPE-Z27
8
DIAMETER
Diameter
PRODUCT DESCRIPTOR
9
mm
9
TOB09
TO
VAPE-Z27
9
NICTNCNC
Nicotine Concentration
PRODUCT DESCRIPTOR
2
mg/L
10
TOB09
TO
VAPE-Z27
10
PRPYLGLY
Propylene Glycol
PRODUCT DESCRIPTOR
50
%
11
TOB09
TO
VAPE-Z27
11
VG
Vegetable Glycerin
PRODUCT DESCRIPTOR
50
%
12
TOB09
TO
VAPE-Z27
12
CHTRFLAV
Characterizing Flavor
PRODUCT DESCRIPTOR
TOBACCO
13
TOB09
TO
VAPE-Z27
13
VOLUMEE
Volume, E-liquid
PRODUCT DESCRIPTOR
1
mL
14
TOB09
TO
VAPE-Z27
14
WATT
Wattage
PRODUCT DESCRIPTOR
5.2
Watt
15
TOB09
TO
VAPE-Z27
15
BATTCAP
Battery Capacity
PRODUCT DESCRIPTOR
600
mAh
16
TOB09
TO
VAPE-Z27
16
DISPCRTG
Disposable Cartridge
PRODUCT DESCRIPTOR
Y
$warningHtml
The manufacturing parameter specifications of the ENDS product as intended for used are represented in the Product Design Parameters (PD) domain. The example below shows the target, minimum, and maximum values associated with each of 33 separate design parameters. These parameters are defined manufacturing specifications, not characteristics that are determined experimentally.
Finally, the Tobacco Product Testing (PT) domain is used to represent the actual results of testing the manufactured ENDS product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a required variable and is set to "DESIGN PARAMETER TESTING" for all records here. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only one replicate per parameter is shown. Note that PTREPNUM (repetition number) =1 for all rows.