The Electrocardiogram (EG) domain includes ECG data, including the position of the subject; method of evaluation; all cycle measurements; and all findings from the ECG, including an overall interpretation, if collected. This data may be collected at the local site, or at a central lab. Routine ECG date collected in clinical trials is often collected at the study site.
Example
This example shows a CRF that collects electrocardiogram data utilizing a local reader.
Order
Question Text
Prompt
Case Report Form Completion Instructions
Type
Collection Variable
Tabulation Target
Mapping Instructions
Controlled Terminology CodeList Name
Permissible Values
Pre-Populated Value
1
Was the ECG performed?
ECG Performed
Indicate whether or not an ECG or specific ECG test was done.
Text
EGSTAT
EGSTAT
(NY)
N;Y
2
What was the method used for the ECG?
Method
Record the method used for the ECG.
Text
EGMETHOD
EGMETHOD
(EGMETHOD)
12 LEAD STANDARD;HOLTER CONTINUOUS ECG RECORDING
3
What was the position of the subject during the ECG measurement?
Position
Record the position of the subject during the ECG.
Record or select the original unit in which these data were collected, if not pre-printed on CRF.
Text
EGHRMN_EGORRESU
EGORRESU
EGORRESU where EGTESTCD = "EGHRMN"
(Unit)
beats/min
7
What was the Aggregate PR Interval?
PR Interval, Aggregate
Record the test result.
Integer
PRAG_EGORRES
EGORRES
EGORRES where EGTESTCD = "PRAG"
8
What was the unit of the Aggregate PR Interval?
Unit
Record or select the original unit in which these data were collected, if not pre-printed on CRF.
Text
PRAG_EGORRESU
EGORRESU
EGORRESU where EGTESTCD = "PRAG"
(Unit)
msecs
9
What was the Aggregate QRS Duration?
QRS Duration, Aggregate
Record the test result.
Integer
QRSAG_EGORRES
EGORRES
EGORRES where EGTESTCD = "QRSAG"
10
What was the unit of the Aggregate QRS Duration?
Unit
Record or select the original unit in which these data were collected, if not pre-printed on CRF.
Text
QRSAG_EGORRESU
EGORRESU
EGORRESU where EGTESTCD = "QRSAG"
(Unit)
msecs
11
What was the Aggregate QT Interval?
QT Interval, Aggregate
Record the test result.
Integer
QTAG_EGORRES
EGORRES
EGORRES where EGTESTCD = "QTAG"
12
What was the unit of the Aggregate QT Interval result?
Unit
Record or select the original unit in which these data were collected, if not pre-printed on CRF.
Text
QTAG_EGORRESU
EGORRESU
EGORRESU where EGTESTCD = "QTAG"
(Unit)
msecs
13
What was the Aggregate QTca Interval?
QTca Interval, Aggregate
Record the test result.
Integer
QTCAAG_EGORRES
EGORRES
EGORRES where EGTESTCD = "QTCA"
14
What was the unit of the Aggregate QTca Interval?
Unit
Record or select the original unit in which these data were collected, if not pre-printed on CRF.
Text
QTCAAG_EGORRESU
EGORRESU
EGORRESU where EGTESTCD = "QTCA"
(Unit)
msecs
15
What was the overall interpretation of the ECG?
Interpretation
Record the the test result.
Text
INTP_EGORRES
EGORRES
EGORRES where EGTESTCD = "INTP"
(NORMABNM)
NORMAL; ABNORMAL
16
Was the ECG clinically significant?
Clinically Significant
Record whether ECG results were clinically significant.
Text
EGCLSIG
EGCLSIG
(NY)
N:Y:
This is the SDTM data associated with the CRF above.
Row 1:
Shows a measurement of ventricular rate.
Row 2:
Shows a measurement of PR interval.
Rows 3-4:
These interval measurements were collected in seconds. However, in this submission, the standard unit for these tests was milliseconds, so the results have been converted in EGSTRESC and EGSTRESN.
Row 5:
Shows "QTcB Interval, Aggregate". This result was derived by the applicant, as indicated by the “Y” in the EGDRVFL column. Note that EGORRES is null for these derived records.
Row 6:
Shows the result of the TEST "Interpretation" (i.e., the interpretation of the ECG strip as a whole), which for this ECG was "ABNORMAL". This result was assessed as clinically significant (EGCLSIG = "Y").
eg.xpt
eg.xpt
Row
STUDYID
DOMAIN
USUBJID
EGSEQ
EGREFID
EGTESTCD
EGTEST
EGCAT
EGPOS
EGORRES
EGORRESU
EGSTRESC
EGSTRESN
EGSTRESU
EGNAM
EGMETHOD
EGDRVFL
EGCLSIG
VISITNUM
VISIT
EGDTC
EGDY
1
XYZ
EG
XYZ-US-701-002
1
334PT89
EGHRMN
ECG Mean Heart Rate
MEASUREMENT
SUPINE
62
beats/min
62
62
beats/min
Test Lab
12 LEAD STANDARD
1
SCREENING
2003-04-15T11:58
-36
2
XYZ
EG
XYZ-US-701-002
2
334PT89
PRAG
PR Interval, Aggregate
INTERVAL
SUPINE
0.15
sec
150
150
msec
Test Lab
12 LEAD STANDARD
1
SCREENING
2003-04-15T11:58
-36
3
XYZ
EG
XYZ-US-701-002
3
334PT89
QRSAG
QRS Duration, Aggregate
INTERVAL
SUPINE
0.103
sec
103
103
msec
Test Lab
12 LEAD STANDARD
1
SCREENING
2003-04-15T11:58
-36
4
XYZ
EG
XYZ-US-701-002
4
334PT89
QTAG
QT Interval, Aggregate
INTERVAL
SUPINE
0.406
sec
406
406
msec
Test Lab
12 LEAD STANDARD
1
SCREENING
2003-04-15T11:58
-36
5
XYZ
EG
XYZ-US-701-002
5
334PT89
QTCA
QTcA Interval, Aggregate
INTERVAL
SUPINE
469
469
msec
Test Lab
12 LEAD STANDARD
Y
1
SCREENING
2003-04-15T11:58
-36
6
XYZ
EG
XYZ-US-701-002
12
334PT89
INTP
Interpretation
SUPINE
ABNORMAL
ABNORMAL
Y
1
SCREENING
2003-04-15T11:58
-36
$warningHtml
Dataset Wrapper Debug Message
Please add a row column to your dataset.
Example
This example shows a SDTM dataset that represents basic electrocardiogram data.
Row 1:
Shows the result of the TEST "Interpretation" (i.e., the interpretation of the ECG strip as a whole), which for this ECG was "ABNORMAL".
Row 2:
Shows an ECG that was not performed and the reason it was not performed.