You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 25 Next »

This is an example of a study were the sponsor collected events associated with the operation of the electronic cigarette device.

SPTOBID
Pre-populated
VAPE-Z01
Record a description of the event that occurred.
PITERM
_________________
Record the date that the event first occurred or was noted using this format (DD-MON-YYYY).
PISTDAT PISTDTC
_________________
Record how often the event occurred.How frequently did the event occur?
PIEPATT PIPATT
Record what action was taken with the tobacco product as a result of the event.What action was taken with the study device?
PIACNDEV
<DEACNDEV codelist>
Record the ID of the primary AE associated with event, if any.
PIAENO(n) ASSOCIATE WITH RELATED RECORD VIA RELREC
_________________
OrderCDASHIG VariableQuestion TextPromptData TypeCRF Completion InstructionsSDTMIG TargetSDTM Variable MappingControlled Terminology Codelist NamePermissible ValuesPre-populated ValueQuery DisplayList StyleHidden
1SPTOBIDWhat was the tobacco product identifier? Tobacco Product Identifier textIndicate the tobacco product that  was involved in the incident.SPTOBID


VAPE-Z01
radio
6PITERM

What was the event associated with this tobacco product? 

Tobacco Product EventtextRecord a description of the event that occurred.PITERM






7PISTDATWhat was the start date when the event first occurred or was identified?Start DatetextRecord the date that the event first occurred or was noted using this format (DD-MON-YYYY).PISTDTC






10PIEPATTHow frequently did the event occur?Event FrequencytextRecord how often the event occurred.PIPATT

Single Event; Intermittent; Continuous

radio
11PIACNDEVWhat action was taken with the study device?Action Taken With DevicetextRecord what action was taken with the tobacco product as a result of the event.PIACNDEV
(DEACNDEV)No Change; Tobacco Product Replaced; 


radio
12PIAENO(n)What was the identifier for the primary adverse event(s) associated with or related to this device event?Related Adverse Event IDtextRecord the ID of the primary AE associated with event, if any.N/AASSOCIATE WITH RELATED RECORD VIA RELREC





The associated SDTM datasets for the data collected above are provided below. The Tobacco Product Identifier (TO) domain is a study reference dataset that provides a mechanism for uniquely identifying a tobacco product. Only one product was of interest in the study.  Note this identifier also describes any device use by the subject to deliver the tobacco.   

to.xpt

to.xpt

RowSTUDYIDDOMAINSPTOBIDTOSEQTOTESTCDTOTESTTOCATTOORRESTOORRESUTOSTRESCTOSTRESNTOSTRESU
1TB005TOVAPE-Z01

1

TBPRDCATTobacco Product CategoryPRODUCT IDENTIFIERENDS (VAPES)
ENDS (VAPES)

2TB005TOVAPE-Z012TBPRSCATTobacco Product SubcategoryPRODUCT IDENTIFIERClosed E-Cigarette
Closed E-Cigarette

3TB005TOVAPE-Z013MANUFManufacturerPRODUCT IDENTIFIERXX Vapes USA
XXX Vapes USA

$warningHtml

The International Medical Device Regulators Forum (IMDRF) document “IMDRF Terminologies for Categorized Adverse Event Reporting (AER): Terms, Terminology Structure and Codes was used by the sponsor. Annex A ( 2022) provide the medical problem codes. The name and version of the dictionary used to map terms must be provided in a Define.XML ExternalCodeList element. DEDCODE was the Level 3 IMDRF term. 

Example PI  Variable Metadata

Variable Label Type Codelist
DEIMDRCDIMDRF CodetextIMDRFANNEXA 
DEIMDRFL2IMDRF Level 2textIMDRFANNEXA
DEIMDRFL1IMDRF Level 1textIMDRFANNEXA


Example External Dictionaries

Codelist

External Dictionary Name

Dictionary Version

Reference

IMDRFANNEXA IMDRF Terminologies for Categorized Adverse Event Reporting (AER): Terms, Terminology Structure and Codes : Annex A 

Release Number: 2022

https://www.imdrf.org/consultations/imdrf-terminologies-categorized-adverse-event-reporting-aer-terms-terminology-structure-and-codes

pi.xpt

pi.xpt

Row

STUDYID

DOMAIN

USUBJID

SPTOBID

PISEQ

PILNKID

PITERM

PIDECOD

PIMODIFY

PIACT

PISTDTC


PIIMDRCD

PIIMDRL2

PIIMDRL1

1

TB005

PI

2029

VAPE-Z01

1


Broken Heater

Mechanical Problem

Mechanical Problem

Device Replaced

2009-12-28


A05

Mechanical Problem

Mechanical Problem

2

TB005

PI

1059

VAPE-Z01

1


Won’t charge

Charging Problem

Charging Problem

Battery Replaced

2009-01-05


A0706

Charging Problem

Electrical /Electronic Property Problem

3

TB005

PI

3067

VAPE-Z01

1

1

Battery Malfunction

Battery Problem

Battery Problem

Battery Replaced

2009-01-05


A0705

Battery Problem

Electrical /Electronic Property Problem

$warningHtml

PI NSV Metadata

Subject 3067 had an AE associated with the battery problem. This was reported in the AE dataset. Not all variables are shown for brevity .  

ae.xpt

xx.xpt

RowSTUDYIDDOMAINUSUBJIDAESEQAELNKIDAETERMEPOCHAESTDTCAEENDTCAESTDYAEENDYAEENRF
1TB005AE306711SKIN REDNESS SCREENING2009-01-052009-01-07-1-1

Dataset Debug Message

There is a leading, trailing, or non-breaking space in the dataset.

The RELREC dataset was used to record the relationship between the Product Events in PI and reported AE represented in AE dataset. 

Row

STUDYID

RDOMAIN

USUBJID

IDVAR

IDVARVAL

RELTYPE

RELID

1TB005PI
PILNKID
ONEAEPI1
2TB005AE
AELNKID
ONEAEPI



  • No labels