This is a study were subjects were randomized to use 3 different concentration of e-nicotine liquid. The subject used the product at home for 2 weeks. This 2-week period allowed subjects to become familiar with the e-cigarette. After two weeks, the subjects were confined to the clinical for one day. They were required to not use any e-cigarettes for 12 hours prior to the visit. Subjects had to have CO level below a pre-specified level, to attend the visit. If the level, was too high, the visit was re-scheduled. Subjects were instructed to take 10 puffs on the e-cigarette. Puff topography was measured using the same device for all subjects.
A Study Reference domain, DI, was used to identify the device used to measure puff topography. The provide a consistent sponsor-defined variable (SPDEVID) for linking data. Device identifiers exist independently from subjects; therefore, the DI domain does not contain USUBJID. Only one device was used for all subjects in the study.
di.xpt
di.xpt
Row
STUDYID
DOMAIN
SPDEVID
DISEQ
DIPARMCD
DIPARM
DIVAL
1
TOPT001
DI
PUFANYXYZ
1
DEVTYPE
Device Type
Puff Topography
Dataset Debug Message
There is a leading, trailing, or non-breaking space in the dataset.
The sponsor submitted the EX domain to represent the usage of the e-cigarettes. For each subject, the usage for the two weeks are represented, and then the specified usage during the in-clinic visit are shown. The sponsor elected not to represent each puff in this EX dataset. Each Puff could have been recorded.
ex.xpt
ex.xpt
Row
STUDYID
DOMAIN
USUBJID
EXSEQ
SPTOBID
EXSPID
EXTRT
EXDOSE
EXDOSU
EXROUTE
EXPSTRG
EXPSTRGU
EXSTDTC
EXENDTC
1
TOPT001
EX
3001
1
EC-333
e-nicotine liquid
AD LIBITUM
INHALED
8
mg/mL
2020-06-26
2020-07-14
2
TENDS01
EX
3001
2
EC-333
PUFF 1
e-nicotine liquid
10
PUFFS
INHALED
8
mg/mL
2020-07-15T9:00
2020-07-15TT9:45
3
TENDS01
EX
4001
3
EC-333
e-nicotine liquid
AD LIBITUM
INHALED
16
mg/mL
2020-09-06
2020-09-22
3
TENDS01
EX
4001
4
EC-333
PUFF 1
e-nicotine liquid
10
PUFFS
INHALED
16
mg/mL
2020-09-22T9:00
2020-09-22T9:30
$warningHtml
The FAEX domain was used to represent the puff topography associated with the in -clinic visit. A puff -by puff analysis was performed. Additionally , the vendor provided the mean puff volume and the mean puff duration for the 10 puffs in the session.
Row 1:
Shows the Number of Puff taken in the interval. This was pre-specified in the design, but the sponsor reported the actual number of puffs taken.
Rows 2-3, 5-6 :
Show the puff volume for Subject 3001 for each puff and the puff duration for Subject 4001. FADTC and FAENDTC provides the timing of each puff. Only data for 2 puffs are shown.
Rows 4 & 7:
Shows the mean puff volume for Subject 3001 and the mean puff duration for Subject 4001for all puffs during the interval provided in FADTC and FAENDTC. The NSV variable FACOLSRT indicates that the Mean puff volume is provided. The method to calculate the mean was provided in FAMETHOD, in this situation the DEVICE ALGORITHM.
Row Captions Debug Message
Please construct row caption labels as instructed in <ac:link><ri:page ri:content-title="Constructing labels for row captions" ri:space-key="TTD"/></ac:link>.
fa.xpt
faex.xpt
Row
STUDYID
DOMAIN
USUBJID
SPDEVID
FASEQ
FASPID
FATESTCD
FATEST
FAOBJ
FACAT
FAORRES
FAORRESU
FASTRESC
FASTRESU
FALOBXFL
FAMETHOD
VISITNUM
FADTC
FAENDTC
FATPT
FACOLSRT
1
TGI400
FA
3001
PUFANYXYZ
1
PUFF TOT
TOTAL NUMBER OF PUFFS
e-nicotine liquid
10
PUFFS
10
PUFFS
2
2020-07-15T9:00
2020-07-15TT9:45
1
TGI400
FA
3001
PUFANYXYZ
2
PUFF 1
PUFFVOL
PUFF VOLUME
e-nicotine liquid
PUFF TOPOGRAPHY
66.7
ml/sec
98
ml/sec
2
2020-07-15T9:00
PUFF 1
2
TGI400
FA
3001
PUFANYXYZ
3
PUFF 2
PUFFVOL
PUFF VOLUME
e-nicotine liquid
PUFF TOPOGRAPHY
43
ml/sec
43
ml/sec
2
2020-07-15T9:11
PUFF 2
3
TGI400
FA
3001
PUFANYXYZ
4
PUFFVOL
PUFF VOLUME
e-nicotine liquid
PUFF TOPOGRAPHY
53.7
ml/sec
53.7
ml/sec
DEVICE ALGORITHM
2
2020-07-15T9:00
2020-07-15TT9:45
MEAN
4
TGI400
FA
4001
PUFANYXYZ
1
PUFF 1
PUFFDUR
PUFF DURATION
e-nicotine liquid
PUFF TOPOGRAPHY
2
sec
2
sec
2
2020-07-22
PUFF 1
5
TGI400
FA
4001
PUFANYXYZ
2
PUFF 2
PUFFDUR
PUFF DURATION
e-nicotine liquid
PUFF TOPOGRAPHY
1.8
sec
1.8
sec
2
2020-07-22
PUFF 2
6
TGI400
FA
4001
PUFANYXYZ
3
PUFFDUR
PUFF DURATION
e-nicotine liquid
PUFF TOPOGRAPHY
1.8
sec
1.8
sec
DEVICE ALGORITHM
2
2020-09-22T9:13
2020-09-22T9:30
MEAN
Dataset Debug Messages
There are seven leading, trailing, or non-breaking spaces in the dataset.