Indicate whether or not lab specimen was collected or measurement performed.
Was the lab performed?
LBPERFLBSTAT = "NOT DONE" where LBPERF = "N" and LBSTAT = null where LBPERF = "Y"
<NY codelist>
Record the date of specimen collection using this format (DD-MON-YYYY).
LBDATLBDTC
_ _ / _ _ _ / _ _ _ _
Record time of collection (as complete as possible).
LBTIMLBDTC
_ _ : _ _ : _ _
Record condition of specimen.
What was the condition of the specimen?
LBSPCCND
<SPECCOND codelist>
Record the laboratory name.
LBNAM
_________________
Record the name of the lab measurement or finding, if not pre-printed on the CRF. If collected on the CRF, the sponsor may provide additional instructions to ensure the data is entered as intended.
Lab Test Name
LBTESTLBTEST and LBTESTCD
<LBTEST codelist>
Record the method of the test or examination.
What was the method used for the lab test or examination?
LBMETHOD
<METHOD codelist>
Record laboratory test result.
LBORRES
_________________
Record or select the original unit in which these data were collected, if not pre-printed on CRF.
Unit
LBORRESU
<UNIT codelist>
Record the lower limit of the reference range of the lab test.
LBORNRLO
_________________
Record the upper limit of the reference range of the lab test.
LBORNRHI
_________________
Record where the lab result fell with respect to the reference range (i.e., HIGH, NORMAL, LOW).
Comparison to Reference Range
LBNRIND
<NRIND codelist>
Record whether lab results were clinically significant.
Was this result clinically significant?
LBCLSIGSUPPLB.QVAL where SUPPLB.QNAM = "LBCLSIG" and SUPPLB.QLABEL = "Clinically Significant"
<NY codelist>
Record the toxicity grade.
What is the Toxicity Grade?
LBTOXGR
Record the description of the toxicity.
LBTOX
_________________
CDASH Variable
Order
Question Text
Prompt
CRF Completion Instructions
Type
SDTMIG Target Variable
SDTMIG Target Mapping
Controlled Terminology Code List Name
Permissible Values
Pre-Populated Value
Query Display
List Style
Hidden
LBCAT
1
What was the name of the lab panel?
Lab Panel Name
Record the lab test category, if not pre-printed on the CRF.
Text
LBCAT
HEMATOLOGY
Prompt
LBSCAT
2
What was name of the lab sub-panel?
Lab Sub-Panel Name
Record the lab test subcategory, if not pre-printed on the CRF.
Text
LBSCAT
COAGULATION
Prompt
LBPERF
3
Was the lab performed?
Lab Performed
Indicate whether or not lab specimen was collected or measurement performed.
Text
LBSTAT
LBSTAT = "NOT DONE" where LBPERF = "N" and LBSTAT = null where LBPERF = "Y"
(NY)
Yes; No
Radio
LBDAT
4
What was the date of the lab specimen collection?
Specimen Collection Date
Record the date of specimen collection using this format (DD-MON-YYYY).
Date
LBDTC
Prompt
LBTIM
5
What was the time of the lab specimen collection?
Specimen Collection Time
Record time of collection (as complete as possible).
Time
LBDTC
Prompt
LBSPCCND
6
What was the condition of the specimen?
Specimen Condition
Record condition of specimen.
Text
LBSPCCND
(SPECCOND)
FRESH; FROZEN; REFRIGERATED
Radio
LBNAM
7
What was the name of the laboratory used?
Laboratory Name
Record the laboratory name.
Text
LBNAM
LBTEST
8
What is the lab test name?
Lab Test Name
Record the name of the lab measurement or finding, if not pre-printed on the CRF. If collected on the CRF, the sponsor may provide additional instructions to ensure the data is entered as intended.
Record or select the original unit in which these data were collected, if not pre-printed on CRF.
Text
LBORRESU
(UNIT)
g/L; mg/dL; mg/L; U/mL; ug/L; sec; RATIO
Prompt
Radio
LBORNRLO
12
What was the lower limit of the reference range for this lab test?
Normal Range Lower Limit
Record the lower limit of the reference range of the lab test.
Text
LBORNRLO
Prompt
LBORNRHI
13
What was the high limit of the reference range for this lab test?
Normal Range Upper Limit
Record the upper limit of the reference range of the lab test.
Text
LBORNRHI
Prompt
LBNRIND
14
How do the reported values compare within the reference range?
Comparison to Reference Range
Record where the lab result fell with respect to the reference range (i.e., HIGH, NORMAL, LOW).
Text
LBNRIND
(NRIND)
High; Normal; Low
Prompt
Radio
LBCLSIG
15
Was this result clinically significant?
Clinically Significant
Record whether lab results were clinically significant.
Text
SUPPLB.QVAL
SUPPLB.QVAL where SUPPLB.QNAM = "LBCLSIG" and SUPPLB.QLABEL = "Clinically Significant"
(NY)
Yes; No
Radio
LBTOXGR
16
What is the Toxicity Grade?
Toxicity Grade
Record the toxicity grade.
Text
LBTOXGR
0; 1; 2; 3; 4
Radio
LBTOX
17
What is the description of the toxicity?
Toxicity
Record the description of the toxicity.
Text
LBTOX
C-Reactive Protein (CRP),LDL),Fibrinogen,(IL-6),total cholesterol,triglycerides ,urinary cotinine test
Rows 1, 9:
Show that glucose was measured for approximately 24 hours, and the mean glucose value was represented in LBORRES/LBSTRESC. The collected summary result is represented in the NSV LBCOLSRT. LBTEST is "Plasma Equivalent Glucose" as the results represent a concentration of glucose.
Rows 8, 16:
Show the GMI results calculated by the device based on glucose results collected during the 14-day period that ended on the day of each visit. The value of the LBANMETH variable indicates that the GMI results were calculated as a percentage based on mean glucose measurements reported in mg/dL.
Rows 2-7, 10-15:
Show other statistics that were calculated by the CGM device from the raw glucose levels collected during the specified interval. Again, LBCOLSRT is used to indicate which summary statistic was calculated for the glucose values collected in this interval. LBTEST is "Plasma Equivalent Glucose Distribution" as these are tests about the distribution of the glucose measurements.