You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 19 Next »

This is an example for the required tobacco product categorization, property description, and design parameter information in an FDA marketing application for one type of tobacco product Cigarette. There are many more and various types of tobacco products, and their parameters can be found in the in the FDA final rule and guidance documents for tobacco products Premarket Authorization (PMTA) and Substantial Equivalence (SE) Pathways. The applicant submitting for SE and PMTAs should provide test data to include test protocols, quantitative acceptance criteria, data sets, and summary of results as applicable for these parameters.

Tobacco Products (TO) is a study reference dataset that provides a mechanism for uniquely identifying a tobacco product. It is similar to Device Identifiers (DI) in function. The primary purpose of this dataset is to provide a list of the products used in an application or study and to provide identifying information for each product, such as product category type, manufacturer, model (product) name, etc., as applicable. All identifying information is grouped by the Sponsor Tobacco Product Identifier (SPTOBID) (similar to Sponsor Device Identifier (SPDEVID) a consistent variable, that is available for use in other domains where data pertaining to the product may be found.


 SPTOBID... ?SPTOBID - should it be SPTOBID for Sponsor Tobacco Product Identifier???

Rows 1-4:Show the records for a tobacco product given SPTOBID of CIG01a.
Rows 3-4:Show the tobacco product is a filtered, combusted type of cigarette.

to.xpt

to.xpt

RowSTUDYIDDOMAINSPTOBIDTOSEQTOPARMCDTOPARMTOVAL
1TOB07TOCIG01a1TBPRDCATTobacco Product CategoryCigarette
2TOB07TOCIG01a2TBPRSCATTobacco Product SubcategoryFiltered, Combusted
3TOB07TOCIG01a3MANUFManufacturerJoes Cigs USA
4TOB07TOCIG01a4TRADENAMTrade NameTreetop Methol King Size
$warningHtml

Dataset Wrapper Debug Message

Please add a row column to your dataset.

The Tobacco Product Design Parameters (DP)  is (similar to the Device Properties (DO) domain) represents properties of the tobacco product as used. This is a findings domain and defines important characteristics of a product that the sponsor manufacturer (tobacco researcher) wishes to include in the submission but do not form part of the unique sponsor-defined identification of the product. Each property is identified using controlled terminology and is stored in TTTESTCD/TTTEST.

Rows 1-4:Show the package type is a hard pack that each contain 20 cigarettes that are 86.0 mm long and 26.0 mm in circumference.
Row 5:Shows the ventilation flow expressed as a percentage. Ventilation is the aspiration of atmospheric air in an unlit cigarette. (ISO 9512:2019) - 1
Row 6:Shows the characterizing flavor is menthol for this package of cigarettes.
Row 7:Shows the heat source is xxx.

dp.xpt

dp.xpt

RowSTUDYIDDOMAINSPTOBIDDPSEQDPTESTCDDPTESTDPCATDPSCATDPORRESDPORRESUDPSTRESCDPSTRESNDPSTRESUDPCOLSRT
1TOB07DPCIG01a1PACKTYPPackage TypeCIGARETTEFILTERED, COMBUSTEDHARD PACK
HARD PACK


2TOB07DPCIG01a2PRDQUANProduct QuantityCIGARETTEFILTERED, COMBUSTED20CIGARETTE2020CIGARETTE
3TOB07DPCIG01a3LENGTHLengthCIGARETTEFILTERED, COMBUSTED86.0mm86.086.0mm
4TOB07DPCIG01a4CIRCUMCircumferenceCIGARETTEFILTERED, COMBUSTED26.0mm26.026.0mm
5TOB07DPCIG01a5VENTLTNVentilationCIGARETTEFILTERED, COMBUSTED10.0%10.010.0%
6TOB07DPCIG01a6CHARFLAVCharacterizing FlavorCIGARETTEFILTERED, COMBUSTEDMENTHOL
MENTHOL


7TOB07DPCIG01a7HTSOURCEHeat SourceCIGARETTEFILTERED, COMBUSTEDxxx
xxx


8

TOB07

DP

Cigarette lengthDESIGN PARAMETER SPECIFICATION
mm




TARGET
9TOB07DP

Cigarette lengthDESIGN PARAMETER SPECIFICATION
mm




MINIMUM
10TOB07DP

Cigarette lengthDESIGN PARAMETER SPECIFICATION
mm




MAXIMUM
11TOB07DP

Cigarette circumference or diameter 2DESIGN PARAMETER SPECIFICATION
mm




TARGET
12TOB07DP

Cigarette circumference or diameter 2DESIGN PARAMETER SPECIFICATION
mm




MINIMUM
13TOB07DP

Cigarette circumference or diameter 2DESIGN PARAMETER SPECIFICATION
mm




MAXIMUM
14TOB07DP

Tobacco Filler massDESIGN PARAMETER SPECIFICATION
mg




TARGET
15TOB07DP

Tobacco Filler massDESIGN PARAMETER SPECIFICATION
mg




MINIMUM
16TOB07DP

Tobacco Filler massDESIGN PARAMETER SPECIFICATION
mg




MAXIMUM
17TOB07DP

Tobacco moisture or Oven VolatilesDESIGN PARAMETER SPECIFICATION
%




TARGET
18TOB07DP

Tobacco moisture or Oven VolatilesDESIGN PARAMETER SPECIFICATION
%




MINIMUM
19TOB07DP

Tobacco moisture or Oven VolatilesDESIGN PARAMETER SPECIFICATION
%




MAXIMUM
20TOB07DP

Tobacco cut size

mm or cuts per inch 2




TARGET
21TOB07DP

Tobacco cut size

mm or cuts per inch 2




MINIMUM
22TOB07DP

Tobacco cut size

mm or cuts per inch 2




MAXIMUM
23TOB07DP

Filter Ventilation

%




TARGET
24TOB07DP

Filter Ventilation

%




MINIMUM
25TOB07DP

Filter Ventilation

%




MAXIMUM
26TOB07DP

Tipping Paper Length

mm




TARGET
27TOB07DP

Tipping Paper Length

mm




MINIMUM
28TOB07DP

Tipping Paper Length

mm




MAXIMUM
29TOB07DP

Cigarette base paper Porosity or Permeability

CORESTA Unit (Cu)




TARGET
30TOB07DP

Cigarette base paper Porosity or Permeability

CORESTA Unit (Cu)




MINIMUM
31TOB07DP

Cigarette base paper Porosity or Permeability

CORESTA Unit (Cu)




MAXIMUM
32TOB07DP

Cigarette Paper band porosity or permeability or band diffusivity

CORESTA Unit (Cu) or cm2/s




TARGET
33TOB07DP

Cigarette Paper band porosity or permeability or band diffusivity

CORESTA Unit (Cu) or cm2/s




MINIMUM
34TOB07DP

Cigarette Paper band porosity or permeability or band diffusivity

CORESTA Unit (Cu) or cm2/s




MAXIMUM
35TOB07DP

Cigarette Paper band width

mm




TARGET
36TOB07DP

Cigarette Paper band width

mm




MINIMUM
37TOB07DP

Cigarette Paper band width

mm




MAXIMUM
38TOB07DP

Cigarette Paper band space

mm




TARGET
39TOB07DP

Cigarette Paper band space

mm




MINIMUM
40TOB07DP

Cigarette Paper band space

mm




MAXIMUM
41TOB07DP

Filter efficiency 1

%




TARGET
42TOB07DP

Filter efficiency 1

%




MINIMUM
43TOB07DP

Filter efficiency 1

%




MAXIMUM
44TOB07DP

Denier per Filament

DPF




TARGET
45TOB07DP

Denier per Filament

DPF




MINIMUM
46TOB07DP

Denier per Filament

DPF




MAXIMUM
47TOB07DP

Total Denier

g/9000 m




TARGET
48TOB07DP

Total Denier

g/9000 m




MINIMUM
49TOB07DP

Total Denier

g/9000 m




MAXIMUM
50TOB07DP

Filter Density

g/cm3




TARGET
51TOB07DP

Filter Density

g/cm3




MINIMUM
52TOB07DP

Filter Density

g/cm3




MAXIMUM
53TOB07DP

Filter Length

mm




TARGET
54TOB07DP

Filter Length

mm




MINIMUM
55TOB07DP

Filter Length

mm




MAXIMUM
56TOB07DP

Filter Pressure Drop

mm H2O




TARGET
57TOB07DP

Filter Pressure Drop

mm H2O




MINIMUM
58TOB07DP

Filter Pressure Drop

mm H2O




MAXIMUM
59TOB07DP

Tobacco Rod Density

g/cm3




TARGET
60TOB07DP

Tobacco Rod Density

g/cm3




MINIMUM
61TOB07DP

Tobacco Rod Density

g/cm3




MAXIMUM
62TOB07DP

Cigarette Paper Length

mm




TARGET
63TOB07DP

Cigarette Paper Length

mm




MINIMUM
64TOB07DP

Cigarette Paper Length

mm




MAXIMUM

Dataset Debug Message

Please remove all formatting (see How to Clear Formatting).

Dataset Wrapper Debug Message

Please add a row column to your dataset.

Rows 1-4: 
Row 5:S
Row 6: 
Row 7: 

Row Captions Debug Message

Please provide a caption for every row caption label.

tt.xpt

tt.xpt

RowSTUDYIDDOMAINSPTOBIDTTSEQTTGRPIDTTTESTCDTTTESTTTCATTTORRESTTORRESUTTSTRESCTTSTRESNTTSTRESUTTCOLSRT
1TOB07TTCIG01a1

Tobacco Filler mass

mg

mg


2TOB07TTCIG01a2

Tobacco moisture or Oven Volatiles

%

%
3TOB07TTCIG01a3

Tobacco cut size

mm or cuts per inch 2

mm or cuts per inch 2
4TOB07TTCIG01a4

Tobacco Rod density

g/cm3

g/cm3
5TOB07TTCIG01a5

Filter Ventilation

%

%
6TOB07TTCIG01a6

Cigarette base paper Porosity or Permeability

CORESTA Unit (Cu)

CORESTA Unit (Cu)
7TOB07TTCIG01a7

Cigarette Paper band porosity or permeability or band diffusivity

CORESTA Unit (Cu) or cm2/s

CORESTA Unit (Cu) or cm2/s
8TOB07TTCIG01a8

Filter efficiency 1

%

%
9TOB07TTCIG01a9

Denier per Filament

DPF

DPF
10TOB07TTCIG01a10

Total Denier

g/9000 m

g/9000 m
11TOB07TTCIG01a11

Filter Density

g/cm3

g/cm3
12TOB07TTCIG01a12

Filter Pressure Drop

mm H2O

mm H2O


Dataset Debug Message

Please remove all formatting (see How to Clear Formatting).

Dataset Wrapper Debug Message

Please add a row column to your dataset.



This images shows the filtration zone where the ventilation occurs.

Question - is this helpful?  Will need permission.  This is from the second reference.



References:

  1. https://www.iso.org/obp/ui/#iso:std:iso:9512:ed-3:v1:en
  2. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6059254/


  • No labels