Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: All JIRA changes
Page properties
Title

4-Stair Descend (4-STAIR DESCEND)

CDISC ReferenceFunctional Test Supplement to the Study Data Tabulation Model Implementation Guide for Human Clinical Trials
QRS Short Name

4-STAIR DESCEND

QRS Permission StatusPublic Domain
TeamDuchenne Muscular Dystrophy (DMD) Standards Team and CDISC Questionnaires, Ratings, and Scales (QRS) Subteam
Supplement Version1.0
StatusDRAFT
Date20222024-0602-0309
NotesThis supplement is intended to be used with other CDISC user guides for specific therapeutic/disease areas and follows the CDISC Study Data Tabulation Model Implementation Guide for Human Clinical Trials.

...

Revision History

DateVersion
20222024-0602-0309
1.0 Draft

© 2022 2024 Clinical Data Interchange Standards Consortium, Inc. All rights reserved. 

1 Introduction

This document describes the CDISC implementation of the 4-Stair Descend (4-STAIR DESCEND) instrument.

...

The CDISC Intellectual Property Policy can be found on the CDISC website at: https://www.cdisc.org/about/bylaws.

1.1 Representations and Warranties, Limitations of Liability, and Disclaimers

This document is a supplement to the SDTMIG for Human Clinical Trials and is covered under Appendix F of that document, which describes representations, warranties, limitations of liability, and disclaimers. Please see Appendix F of the SDTMIG for a complete version of this material.

...

Although the United States Food and Drug Administration (US FDA) has provided input with regard to this supplement, this input does not constitute US FDA endorsement of any particular instrument.

2 Copyright Status

CDISC believes this instrument to be in the public domain, but you should perform your own assessment. CDISC has included the 4-STAIR DESCEND in the library CDISC inventory of QRS data standards supplements. Hence, CDISC developed FTTESTCD and FTTEST for each item based on the actual text on the instrument 

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-613
. There may be many versions of this instrument in the public domain or copyrighted. CDISC has chosen to use this version as the data standard.

...

McDonald CM, Henricson EK, Abresch RT, et al. The 6-minute walk test

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-614
and other clinical endpoints in duchenne muscular dystrophy: reliability, concurrent validity, and minimal clinically important differences from a multicenter study. Muscle Nerve. 2013;48(3):357-68
Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-615
.


3 The FT Domain Model

3.1 Assumptions for FT Domain Model

All assumptions and business rules described in the SDTMIG FT domain are applicable to this supplement. Additional assumptions specific to the 4-STAIR DESCEND are listed below.

...

  1. The numerical value for the time to complete the 4-STAIR DESCEND is recorded using ISO 8601 format in FTORRES and FTSTRESC. Because ISO 8601 format is a text format, there are no standard numeric scores or units. The sponsor enters the time on the CRF in minutes and seconds according to their protocol. (e.g., 1 minute 10 seconds is represented in the FT domain in ISO 8601 format as "T1M10S")
  2. For the test grade (where FTTESTCD = "D4STR104"), FTORRES is populated with the text description. The numeric rating is represented in FTSTRESC and FTSTRESN.

  3. If the entire instrument was not done, the first question on the CRF represents the reason the entire instrument was not done. If the reason not done is provided, then FTSTAT = "NOT DONE" and FTREASND is equal to the text written on the form for all the test codes. 

    1. If the test was not done due to disease, the record where FTTESTCD = "D4STR101" will have FTORRES and FTSTRESC equal to "No, Due to disease under study" and the test grade (FTTESTCD = "D4STR104") will be represented with a value of 1 = "Unable to walk independentlydescend 4 standard stairs."

      Jira
      showSummaryfalse
      serverIssue Tracker (JIRA)
      serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
      keyQRSSUPP-616
      .

  4. Some items on the 4-STAIR

    DESCEND

    ASCEND may be

    logically skipped

    conditionally branched per the instrument instructions. If the test was not done because of disease, FTTESTCD = "D4STR102" and "D4STR103" are not done and are treated as

    logically skipped

    conditionally branched items. A record is created in ft.xpt for all items. When an item is considered a

    logically skipped

    conditionally branched item, it is represented as follows:

    FTSTAT
    1. QNAM = "FTCBRFL", QLABEL = "

    NOT DONE"     
  5. FTREASND = "LOGICALLY SKIPPED ITEM

    Jira
    showSummaryfalse
    serverIssue Tracker (JIRA)
    serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
    keyQRSSUPP-617
    "

    1. Conditionally Branched Item Flag", QVAL = "Y" (this is a FT supplemental qualifier variable related to the record).

    2. FTORRES, FTSTRESC, and FTSTRESN are set to null (missing).

    5. Terminology:
    1. FTCAT, FTTESTCD, and FTTEST values are included in CDISC Controlled Terminology.

    2. A full list of value sets for result and units fields is provided in Section 4, SDTM Mapping Strategy.

3.2 Example for the 4-STAIR DESCEND FT Domain Model

The 4-STAIR DESCEND example below shows the terminology used to implement the instrument in the FT domain. This example shows

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-618
the data for 1 subject collected at the baseline visit for the 4-STAIR DESCEND instrument, and data for 1 subject 2 subjects who did not perform the test, 1 who refused and 1 who could not do the test because of disease progression. The example uses CDISC Controlled Terminology for FTTESTCD, FTTEST, FTORRESU, FTSTRESU,
Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-619
and FTCAT. All original results, matching the CRF item response text, are represented in FTORRES. This result is then represented as a standard numeric score in FTSTRESN and as a standard character representation in FTSTRESC.

...

Dataset wrap
Nameft
Rowcaps
Rows 1-4:

Show a subject who refused to do the test.  All 4 questions were marked as not done with the reason written at the top of the CRF.

Rows 5-8:Show a subject who was not able to do the test due to disease progression. Rows 6 and 7 are logically skipped items because the subject was not able to do the 4-stair descend. The test grade is shown on row 8.
Rows 9-12:Show a subject who was able to complete the test.
Dataset2
RowSTUDYIDDOMAINUSUBJIDFTSEQFTTESTCDFTTESTFTCATFTORRESFTSTRESCFTSTRESNFTSTATFTREASNDFTLOBXFLVISITNUMFTDTC
1STUDYXFT1001-0011D4STR101D4STR1-Was 4-Stair Descend Performed4-STAIR DESCEND


NOT DONEREFUSEDY12015-05-15
2STUDYXFT1001-0012D4STR102D4STR1-Time to Do 4-Stair Descend4-STAIR DESCEND


NOT DONEREFUSEDY12015-05-15
3STUDYXFT1001-0013D4STR103D4STR1-Wear Orthoses4-STAIR DESCEND


NOT DONEREFUSEDY12015-05-15
4STUDYXFT1001-0014D4STR104D4STR1-Test Grade4-STAIR DESCEND


NOT DONEREFUSEDY12015-05-15
5STUDYXFT1001-0021D4STR101D4STR1-Was 4-Stair Descend Performed4-STAIR DESCENDNo, Due to disease under studyNo, Due to disease under study


Y12015-05-15
6STUDYXFT1001-0022D4STR102D4STR1-Time to Do 4-Stair Descend4-STAIR DESCEND


NOT DONELOGICALLY SKIPPED ITEM
Y12015-05-15
7STUDYXFT1001-0023D4STR103D4STR1-Wear Orthoses4-STAIR DESCEND


NOT DONELOGICALLY SKIPPED ITEM
Y12015-05-15
8STUDYXFT1001-0024D4STR104D4STR1-Test Grade4-STAIR DESCENDUnable to descend 4 standard stairs.11

Y12015-05-15
9STUDYXFT1001-0031D4STR101D4STR1-Was 4-Stair Descend Performed4-STAIR DESCENDYesY


Y12015-05-15
10STUDYXFT1001-0032D4STR102D4STR1-Time to Do 4-Stair Descend4-STAIR DESCENDPT1M32SPT1M32S


Y12015-05-15
11STUDYXFT1001-0033D4STR103D4STR1-Wear Orthoses4-STAIR DESCENDNoN


Y12015-05-15
12STUDYXFT1001-0034D4STR104D4STR1-Test Grade4-STAIR DESCENDDescends 4 standard stairs alternating feet, needs handrail for support.55

Y12015-05-15


The conditionally branched item flag text value for data collection needs to be populated in SUPPFT as follows. The standard terminology for QNAM and QLABEL are listed below.

Dataset wrap
Namesuppft
STUDYIDRDOMAINUSUBJIDIDVARIDVARVALQNAMQLABELQVALQORIG
STUDYXFT1001-002QSSEQ2FTCBRFLConditionally Branched Item FlagYCRF
STUDYXFT1001-002QSSEQ3FTCBRFLConditionally Branched Item FlagYCRF


4 SDTM Mapping Strategy

This section is used for reference regarding the CRF data capture and to understand the alignment of the instrument to the SDTM FT domainFT domain. It also provides guidance on how the result and unit variables (FTORRES, FTSTRESC, FTSTRESN, FTORRESU, and FTSTRESU)

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-620
 should be populated.

...