1 Introduction
This document describes the CDISC implementation of the Non-Small Cell Lung Cancer Symptom Assessment Questionnaire v1.0 (NSCLC-SAQ V1.0), a patient-reported outcome (PRO) questionnaire) instrument
. Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-268
CDISC does not modify questionnaires, ratings, and scales (QRS) instruments to meet Clinical Data Acquisition Standards Harmonization (CDASH) case report form (CRF) standards.
The representation of data collected for this questionnaire instrument is based
Jira | ||||||||
---|---|---|---|---|---|---|---|---|
|
Jira | ||||||||
---|---|---|---|---|---|---|---|---|
|
These specific implementation details for this questionnaire instrument are meant to be used in conjunction with the SDTMIG. All CDISC QRS documentation packages can be found on the CDISC website at: https://www.cdisc.org/foundational/qrs.
The CDISC Intellectual Property Policy can be found on the CDISC website at: https://www.cdisc.org/about/bylaws.
1.1 Representations and Warranties, Limitations of Liability, and Disclaimers
This document is a supplement to the SDTMIG for Human Clinical Trials and is covered under Appendix F of that document, which describes representations, warranties, limitations of liability, and disclaimers. Please see Appendix F of the SDTMIG for a complete version of this material.
CDISC specifies how to structure the data that has been collected in a database, not what should be collected or how to conduct clinical assessments or protocols. CDISC disclaims
any liability for your use of this material. Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-274
Although the United States Food and Drug Administration (US FDA) has provided input with regard to this supplement, this input does not constitute US FDA endorsement of any particular instrument.
2 Copyright Status
Critical Path Institute owns the copyright for the NSCLC-SAQ V1.0 and has granted CDISC permission to include this supplement in the CDISC library of QRS data standards supplements.
Hence, CDISC developed QSTESTCD and QSTEST for each item based on the actual text on the instrument. Jira showSummary false server Issue Tracker (JIRA) columns key,summary,type,created,updated,due,assignee,reporter,priority,status,resolution serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-224
The CDISC The CDISC documentation of this instrument consists of: (1) controlled terminology, (2) standard database structure with examples, and (3) CRF(s) annotated with the CDISC SDTMIG variables with submission values.
...
CDISC has developed this documentation at no cost to the copyright holder or any additional cost to users of the instrument beyond the normal license fees charged by the copyright holder.
CDISC acknowledges Critical acknowledges the Critical Path Institute for approval
to include the NSCLC-SAQ V1.0 in the CDISC data standards. Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-225
Reference for the Non-Small Cell Lung Cancer Symptom Assessment Questionnaire v1.0 ( NSCLC-SAQ V1.0): Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-226
- Patient-Reported Outcome (PRO) Consortium - Non-Small Cell Lung Cancer Symptom Assessment Questionnaire (NSCLC-SAQ) Provisional User Manual, Version 6: March 24, 2017.
Jira showSummary false server Issue Tracker (JIRA) columns Jira server Issue Tracker (JIRA) columns key,summary,type,created,updated,due,assignee,reporter,priority,status,resolution serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-227 - McCarrier KP, Atkinson TM, DeBusk KP, Liepa AM, Scanlon M, Coons SJ and on behalf of the Patient-Reported Outcome Consortium. Qualitative Development and Content Validity of the Non-small Cell Lung Cancer Symptom Assessment Questionnaire (NSCLC-SAQ), A Patient-reported Outcome Instrument. Clinical Therapeutics
2016; 38(4):794-810.Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-228
3 The QS Domain Model
3.1 Assumptions for the QS Domain Model
All assumptions and business rules described in the SDTMIG QS domain are applicable to this supplement. Additional assumptions specific to the NSCLC-SAQ V1.0 are listed below. This instrument is intended to be administered electronically per the user manual but a paper option exists if electronic administration is not possible. See the user manual for further details.The NSCLC-SAQ V1.0 is a PRO questionnaire to assess key symptoms
Jira | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
The NSCLC-SAQ V1.0 is a PRO instrument that assesses key symptoms
of 229 of advanced non-small cell lung cancer (NSCLC) over the past 7 days as an endpoint measure in clinical trials. Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-229
These concept domains are described in the manual which will be received upon user copyright approval. Jira showSummary false server Issue Tracker (JIRA) columns key,summary,type,created,updated,due,assignee,reporter,priority,status,resolution serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-230
Respondents respond to each of Each of the 7 items using is rated on a 5-point verbal rating scale
from either "No <symptom> at All" to "Very Severe <symptom>", or from "Never" to "Always" , (depending on the item's question structure), relative to either intensity or frequency. For the NSCLC-SAQ V1.0, QSORRES is populated with the text description of the rating scale response chosen.Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-231 Jira server Issue Tracker (JIRA) columns key,summary,type,created,updated,due,assignee,reporter,priority,status,resolutionserverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 No score is displayed for any item on the questionnaire instrument in either the paper form or the electronic format; however, the user manual for the CRF includes the standardized representation of 0 zero (e.g., "No Coughing at All”, “No Pain at All”, “Never”) through 4 (e.g., “Very Severe Coughing”, "Very Severe Pain", “Always”). Because (a) electronic administration is expected frequently, (b) instructions are provided in the user manualkey QRSSUPP-232
for scoring from C-Path's PRO Consortium, and (c) the numeric score for each question is expected to be submitted with the data, CDISC will represent the standardized scores in QSSTRESC and QSSTRESN.Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-233 The time period of evaluation for the NSCLC-SAQ V1.0 is populated in the QSEVLINT field in ISO 8601 format when the evaluation interval can be precisely described as duration. The evaluation interval for the NSCLC-SAQ V1.0 is the past 7 days.
If no response is provided for an item, then QSORRES, QSSTRESC, and QSSTRESN are all set to null and QSSTAT = “NOT DONE”.
A total score, ranging from 0-20, and 5 subscores, not collected on the NSCLC-SAQ V1.0 CRF , may be submitted as an Electronic Data Transfer (eDT)but documented in the user manual, are considered as captured data and are not considered as derived in the example below.
along with the individual item data for the NSCLC-SAQ V1.0. This original result will be recorded in QSORRES and a standardized representation of the score will be populated in QSSTRESC and QSSTRESN when it is included.Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-234
These scores may be submitted in SDTM or derived in the Analysis Data Model (ADaM) per scoring instructions from user manual.Jira showSummary false server Issue Tracker (JIRA) columns key,summary,type,created,updated,due,assignee,reporter,priority,status,resolution serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-235 If If operationally defined by the sponsor, it is the sponsor's responsibility to set the --DRVFL flag based on their eCRF process to derive subtotals and total scores. An investigator-derived score written on a CRF will be considered a captured score and not flagged. When subtotal and total scores are derived by the sponsor, the derived flag (--DRVFL) is set to Y.
However, when the subtotal and total scores are received from a central provider or vendor, the value would go into QSORRES and QSDRVFL would be null (See SDTMIG Section: 4.1.Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-236
would be null (See SDTMIG Section 4.1.8.1, Origin Metadata for Variables).Jira showSummary false server Issue Tracker (JIRA) columns key,summary,type,created,updated,due,assignee,reporter,priority,status,resolution serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-237
Subscores for the NSCLC-SAQ V1.0 concept domains (e.g., cough) will be derived in the Analysis Data Model (ADaM).
- Terminology
QSCAT, QSTESTCD, and QSTEST values are included in CDISC Controlled Terminology.
A full list of value sets for the result field is provided in Section 4, SDTM Mapping Strategy.
3.2 Example for the NSCLC-SAQ V1.0 QS Domain Model
The NSCLC-SAQ V1.0 example below shows the terminology used to implement the instrument in the QS domain. This example shows the data for 1 subject collected at the baseline visit for a NSCLC-SAQ V1.0 instrument. The example uses CDISC Controlled Terminology for QSTESTCD, QSTEST, and QSCAT. All original results are represented with preferred terminology in QSORRES. This result is then transformed into the standard numeric score in QSSTRESN and a character representation of the standard numeric score in QSSTRESC.
The table represents the questions from the NSCLC-SAQ V1.0 form. This example is based on a questionnaire with an evaluation interval of the past 7 days. Row 8 shows the total score for the NSCLC-SAQ V1.0.
If scores are received by the sponsor, it is recommended that they are submitted to SDTM and verified in ADaM.
Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-238 Jira showSummary false server Issue Tracker (JIRA) columns key,summary,type,created,updated,due,assignee,reporter,priority,status,resolution serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-239
- Terminology
QSCAT, QSTESTCD, and QSTEST values are included in CDISC Controlled Terminology.
A full list of value sets for the result field is provided in Section 4, SDTM Mapping Strategy.
3.2 Example for the NSCLC-SAQ V1.0 QS Domain Model
The NSCLC-SAQ V1.0 example below shows the terminology used to implement the instrument in the QS domain. This example shows the data for 2 subjects collected at the baseline visit for a NSCLC-SAQ V1.0 instrument. The example uses CDISC Controlled Terminology for QSTESTCD, QSTEST, and QSCAT. All original results are represented with preferred terminology in QSORRES. This result is then transformed into the standard numeric score in QSSTRESN and a character representation of the standard numeric score in QSSTRESC.
The table represents the items from the NSCLC-SAQ V1.0 instrument
. Rows 14-26 show the subject was not evaluated on this instrument at visit 1. Because the reason for not completing the visit was not collected, no date is assumed for when the visit would have occurred. Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-240
Jira | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
Info | ||
---|---|---|
| ||
The second subject's missing VISITNUM-1 items were abbreviated by representing the first 3 items and then using the "..." approach to indicate that all items up to the last item represented were missing. We would like input regarding whether you (1) agree with this approach or (2) prefer that all items should be listed in the missing-visit use case moving forward. |
Dataset wrap | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dataset wrap | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
4 SDTM Mapping Strategy
This section is used for reference regarding the CRF data capture and to understand the alignment of the instrument to the SDTM QS domain. It also provides guidance on how the result variables (QSORRES, QSSTRESC, and QSSTRESN) should be populated.
...