Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The example shows the representation of device information, such as the CMR device manufacturer, software and version information, and the specific settings for each subject. Study requirements determine what data is needed.

The example PR dataset shows the cardiac MRI. The device identifier data is represented using SPDEVID and PRREFID. This information shows what device is used and the This example Procedures (PR) dataset includes the SPDEVID variable to show what device was used and the PRREFID variable to represent the accession number or procedure reference identifier associated with the specific procedure for subject DMD-RT-01-301. The SPDEVID variable is was used to relate link this PR dataset record to other records by the device (in this case, the CMR machine)records.

Dataset wrap
Namepr
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

PRSEQ

PRREFID

PRLNKID

PRTRT

PRLOC

PRSTDTC

1

DMD-RT

PR

DMD-RT-01-301

ABC001

1

12345678

04

MRI

HEARTCARDIAC MAGNETIC RESONANCE IMAGING

2023-08-01

The This example cardiovascular system findings (CV) dataset below shows how to represent longitudinal relaxation time, transverse relaxation time, and extracellular volume findings from CMR . The timing of the contrast specificity is noted using the CVTPT to note if the CVTEST was done before or after contrast. CVTPTREF associates the timepoints in CVTPT with "contrast administration." imaging. This example includes records for an unreadable image and an unperformed test. For these records, CVSTAT was populated with "NOT DONE" and CVREASND was populated with the reason the result was not provided or the procedure was not done. The non-standard variable CVOIQ = Overall Image Quality is An NSV was used to represent image quality.

Dataset wrap
Namecv
Rowcaps

Rows 1-6:

Show the longitudinal relaxation time and the transverse relaxation time for different segments of the heart prior to contrast (CVTPT = BEFORE and CVTPTREF = CONTRAST ADMINISTRATION).

Rows 7-8:

Show the longitudinal relaxation time and myocardial extracellular volume for

different segments of the heart after contrast

the LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT after contrast (CVTPT = AFTER and CVTPTREF = CONTRAST ADMINISTRATION).

Row 9:

Shows an unreadable CMR result for participant DMD-RT-01-302, CVREASND = "NON-EVALUABLE IMAGE".

Row 10:

Shows participant DMD-RT-01-303 did not have a CMR procedure because they were unable to place an intravenous access line, CVREASND = "UNABLE TO PLACE INTRAVENOUS LINE".
Dataset2

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVLNKID

CVTESTCD

CVTEST

CVORRES

CVORRESU

CVSTRESC

CVSTRESN

CVSTRESU

CVSTAT

CVREASND

CVLOC

CVMETHOD

CVLOBFXL

VISITNUM

VISIT

CVTPT

CVTPTREF

CVDTC


CVOIQ

1DMD-RTCVDMD-RT-01-301104T1LONGITUDINAL RELAXATION TIME (T1 TIME)Longitudinal Relaxation Time

1315

ms

1315

1315ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
2DMD-RTCVDMD-RT-01-301204T1LONGITUDINAL RELAXATION TIME (T1 TIME)Longitudinal Relaxation Time1166ms11661166ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
3DMD-RTCVDMD-RT-01-301304T1LONGITUDINAL RELAXATION TIME (T1 TIME)Longitudinal Relaxation Time

980

ms

980

980ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
4DMD-RTCVDMD-RT-01-301404T2TRANSVERSE RELAXATION TIME (T2 TIME)Transverse Relaxation Time

45

ms4545ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
5DMD-RTCVDMD-RT-01-301504T2TRANSVERSE RELAXATION TIME (T2 TIME)Transverse Relaxation Time

40

ms4040ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
6DMD-RTCVDMD-RT-01-301604T2TRANSVERSE RELAXATION TIME (T2 TIME)Transverse Relaxation Time

48

ms4848ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
7DMD-RTCVDMD-RT-01-301704T1LONGITUDINAL RELAXATION TIME (T1 TIME)Longitudinal Relaxation Time

450

ms450450ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1AFTERCONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
8DMD-RTCVDMD-RT-01-301804MYECV

MYOCARDIAL EXTRACELLULAR VOLUMEMyocardial Extracellular Volume

25

%2525%



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1AFTERCONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
9DMD-RTCVDMD-RT-01-3021
CVALLCARDIOVASCULAR SYSTEM FINDINGSCardiovascular System Findings




NOT DONE

NON-EVALUABLE IMAGE

HEART

CARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05
NON-EVALUABLE IMAGE
10DMD-RTCVDMD-RT-01-3031
CVALLCARDIOVASCULAR SYSTEM FINDINGSCardiovascular System Findings




NOT DONE

UNABLE TO PLACE INTRAVENOUS LINE

HEART

CARDIAC MAGNETIC RESONANCE IMAGINGMRI
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05

Nsvmeta
DomainCV

Variable

Label

Type

Role

Origin

CVOIQOverall Image QualitytextNon-standard Record QualifierCRF

The example Procedure Agents (AG) dataset shows details for the gadolinium-based contrast that was used for the procedure.

Dataset wrap
Nameag
Dataset2

Row

STUDYID

DOMAIN

USUBJID

AGSEQ

AGLNKID

AGTRT

AGCAT

AGDOSE

AGDOSU

AGDOSFRM

AGROUTE

AGSTDTC

1

DMD-RT

AG

DMD-RT-01-301

1

04

Gd-DOTA

CONTRAST AGENT

8

mL

SOLUTION

INTRAVENOUS

2023-08-01

The device identifiers Device Identifiers (DI) domain is used to represent the device information details. Characteristics recorded in a DI dataset are those necessary to identify each device to the level of granularity necessary for the study (e.g., to the model level if knowing the actual unit is not necessary, to the serial number level if there is a need to distinguish among units).

...

Fixed properties of devices are represented in the Device Properties (DO) domain. The sponsor chose to keep the software version constant throughout the study. DO should contain properties that are important for interpreting the data.

Dataset wrap
Namedo
Dataset2
Row

STUDYID

DOMAIN

SPDEVID

DOSEQ

DOTESTCD

DOTEST

DOORRES

DOORRESU

1

DMD-RT

DO

ABC002ABC001

1

SFTWRNAM

Software Name

CMRRLXU2


2

DMD-RT

DO

ABC002ABC001

2

SFTWRVER

Software Version

CMRLX.2


3

DMD-RT

DO

ABC002ABC001

3IMAQDIMImage Acquisition Dimensionality3

Changeable properties and parameters of devices are represented in the device Device-in-use Use (DU) domain. These settings could can be linked to the record records in the CV domain dataset by their shared SPDEVID and DTC values. For brevity, only 1 subject's parameters are shown.

...

The RELREC dataset is used to describe the relationship between 2 or more records in different domains. For more information on relating records, see SDTMIG v3.4, Section 8.2.

Dataset wrap
Namerelrec
Dataset2

Row

STUDYID

RDOMAIN

USUBJID

IDVAR

IDVARVAL

RELTYPE

RELID

1

DMD-RT

PR


PRLNKID


ONE

04

2

DMD-RT

CV


CVLNKID


MANY

04

3

DMD-RT

AG


AGLNKID


ONE

04