The This example includes information about how to represent imaging device information in the event that the research requires this type of data. When the requirements of the study data include the CMR device manufacturer, software and version information, and the specific settings for each subject, how to model this type of information is included in this example. The requirements of the study determine what data is needed. This examples shows how to do it, if it is desired.The PR dataset shows the procedure of cardiac magnetic resonance imaging using the device associated with SPDEVID ABC001 and the PRREFID of 12345678. This information shows what CMR device is used for the procedure and Procedures (PR) dataset includes the SPDEVID variable to show what device was used and the PRREFID variable to represent the accession number or procedure reference identifier associated with the specific procedure for subject 301. The SPDEVID variable is was used to relate records by the device (in this case, the CMR machine). The Device Identifier (DI) domain represents the device information details, the Device Properties (DO) domain represents characteristics of the device that do not vary between subjects. The Device-In-Use (DU) domain represents settings that are set on a device when it is used and may vary between participants.link this PR record to the device records.

Dataset wrap
Namepr
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

PRSEQ

PRREFID

PRLNKID

PRTRT

PRLOC

PRSTDTC

1

DMD-RT

PR

DMD-RT-01-301

ABC001

1

12345678

04

CARDIAC MAGNETIC RESONANCE IMAGING

MRI

HEART

2023-08-01

The Cardiovascular System Findings This example cardiovascular system findings (CV) domain represents physiological and morphological findings related to the cardiovascular system so it holds the assessments from the parametric mapping. The example CV dataset below shows how to represent longitudinal relaxation time, transverse relaxation time, and extracellular volume findings from CMR . The timing of the contrast specificity is noted using the CVTPT to note if the CVTEST was done before or after contrast. CVTPTREF associates the timepoints in CVTPT with "contrast administration." In the example below, row 9 shows an unreadable CMR using the CVSTAT variable imaging. This example includes records for an unreadable image and an unperformed test. For these records, CVSTAT was populated with "NOT DONE" and the CVREASND variable shows was populated with the reason the procedure result was not done, provided or in this case the result not provided which was a non-evaluable image. A similar approach may be used if there is a desire to record that the CMR was not obtained at the specific visit (omitting the poor-quality information) and why in the dataset records. The non-standard variable CVOIQ=Cardiovascular Overall Image Quality is used to represent if the image for the evaluation is "non-evaluable", "evaluable", "evaluable Image - sub-optimal", or "evaluable image - optimal"procedure was not done. An NSV was used to represent image quality.

Dataset wrap
Namecv
Rowcaps

Rows 1-6:

Show the

T1 Longitudinal Relaxation Time, and the T2 Transverse Relaxation Time, (Native T1 Mapping)

longitudinal relaxation time and the transverse relaxation time for different segments of the heart prior to contrast

for CMR

(CVTPT = BEFORE and CVTPTREF = CONTRAST ADMINISTRATION).

Rows 7-8:

Show the

T1 Longitudinal Relaxation Time, Native T1 Mapping, and Extracellular volume for different segments of the heart after contrast for CMR

longitudinal relaxation time and myocardial extracellular volume for the LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT after contrast (CVTPT = AFTER and CVTPTREF = CONTRAST ADMINISTRATION).

Row 9:

Shows an unreadable CMR result for participant 302 had a CMR procedure that was unreadableDMD-RT-01-302, CVREASND = "NON-EVALUABLE IMAGE". This is denoted by CVTESTCD = "CARDIOVASCULAR SYSTEM FINDINGS" and CVMETHOD = "CARDIAC MAGNETIC RESONANCE IMAGING".

Row 10:

Shows participant DMD-RT-01-303 did not have a CMR procedure because they were unable to place an intravenous access line, CVREASND = "UNABLE TO PLACE INTRAVENOUS LINE".
EXTRACELLULAR VOLUME
Dataset2

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVLNKID

CVTESTCD

CVTEST

CVORRES

CVORRESU

CVSTRESC

CVSTRESN

CVSTRESU

CVSTAT

CVREASND

CVLOC

CVMETHOD

CVLOBFXL

VISITNUM

VISIT

CVTPT

CVTPTREF

CVDTC


CVOIQ

1DMD-RTCVDMD-RT-01-301104T1
LONGITUDINAL RELAXATION TIME (T1 TIME)
Longitudinal Relaxation Time

1315

ms

1315

1315ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
2DMD-RTCVDMD-RT-01-301204T1
LONGITUDINAL RELAXATION TIME (T1 TIME)
Longitudinal Relaxation Time1166ms11661166ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
3DMD-RTCVDMD-RT-01-301304T1
LONGITUDINAL RELAXATION TIME (T1 TIME)
Longitudinal Relaxation Time

980

ms

980

980ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
4DMD-RTCVDMD-RT-01-301404T2
TRANSVERSE RELAXATION TIME (T2 TIME)
Transverse Relaxation Time

45

ms4545ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
5DMD-RTCVDMD-RT-01-301504T2
TRANSVERSE RELAXATION TIME (T2 TIME)
Transverse Relaxation Time

40

ms4040ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
6DMD-RTCVDMD-RT-01-301604T2
TRANSVERSE RELAXATION TIME (T2 TIME)
Transverse Relaxation Time

48

ms4848ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
7DMD-RTCVDMD-RT-01-301704T1
LONGITUDINAL RELAXATION TIME (T1 TIME)
Longitudinal Relaxation Time

450

ms450450ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1AFTERCONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
8DMD-RTCVDMD-RT-01-301804
EXTRAVOL
MYECV

Myocardial Extracellular Volume

25

%2525%



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1AFTERCONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
9DMD-RTCVDMD-RT-01-3021
CVALL
CARDIOVASCULAR SYSTEM FINDINGS
Cardiovascular System Findings




NOT DONE

NON-EVALUABLE IMAGE

HEART

CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05
NON-EVALUABLE IMAGE
10DMD-RTCVDMD-RT-01-3031
CVALL
CARDIOVASCULAR SYSTEM FINDINGS
Cardiovascular System Findings




NOT DONE

UNABLE TO PLACE INTRAVENOUS LINE

HEART

CARDIAC MAGNETIC RESONANCE IMAGING
MRI
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05

Nsvmeta
DomainCV

Variable

Label

Type

Role

Origin

CVOIQOverall Image QualitytextNon-standard Record QualifierCRF

The example Procedure Agents (AG) dataset shows details for the Gadolinium gadolinium-based contrast that was used for the procedure. In this example, the researchers did not collect the time of the contrast.

Dataset wrap
Nameag
Dataset2

Row

STUDYID

DOMAIN

USUBJID

AGSEQ

AGLNKID

AGTRT

AGCAT

AGDOSE

AGDOSU

AGDOSFRM

AGROUTE

AGSTDTC

1

DMD-LGERT

AG

DMD-RT-01-301

1

04

Gd-DOTA

CONTRAST AGENT

8

mL

SOLUTION

INTRAVENOUS

2023-08-01

The Device Identifiers (DI) domain represents is used to represent the device identifier information that describes the device used to produce the image that was the basis of the interpretation recorded in the CV domain. Characteristics in DI information details. Characteristics recorded in a DI dataset are those necessary to identify each device to the level of granularity necessary for the study (e.g., to the model level if knowing the actual unit is not necessary, to the serial number level if there is a need to distinguish among units).

Dataset wrap
Namedi
Dataset2

Row

STUDYID

DOMAIN

SPDEVID

DISEQ

DIPARMCD

DIPARM

DIVAL

1

DMD-LGERT

DI

ABC001

1

DEVTYPE

Device Type

CMR Scanner

2

DMD-LGERT

DI

ABC001

2

MANUF

Manufacturer

ACME

3

DMD-LGERT

DI

ABC001

3

TRADENAM

Trade Name

ACME 64

4

DMD-LGERT

DI

ABC001

4

MODEL

Model Number

CMR540

Fixed properties of devices are represented in the Device Properties (DO) domain. The sponsor chose to keep the software version constant throughout the study. DO should contain properties that are important for interpreting the data.

Dataset wrap
Namedo
Dataset2
Row

STUDYID

DOMAIN

SPDEVID

DOSEQ

DOTESTCD

DOTEST

DOORRES

DOORRESU

1

DMD-LGERT

DO

ABC002ABC001

1

SFTWRNAM

Software Name

CMRRLXU2


2

DMD-LGERT

DO

ABC002ABC001

2

SFTWRVER

Software Version

CMRLX.2


3

DMD-LGERT

DO

ABC002ABC001

3IMAQDIMImage Acquisition Dimensionality3

Changeable properties and parameters of devices are represented in the Device-in-Use (DU) domain. These settings could can be linked to the record records in the CV domain dataset by their shared SPDEVID and DTC values. For brevity, only 1 subject's parameters are shown.  For more information on relating records, see SDTMIG v3.4 Section 8.2, Relating Peer Records. 

Dataset wrap
Namedu
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

DUSEQ

DUREFID

DUTESTCD

DUTEST

DUORRES

DUORRESU

DUSTRESC

DUSTRESN

DUSTRESU

DUDTC

1

DMD-

LGE

RT

DU

DMD-RT-01-301

ABC001

1

12345678

ANTPLANAnatomical PlaneSAGITTAL
SAGITTAL

2023-08-01

2

DMD-

LGE

RT

DU

DMD-RT-01-301

ABC001

2

12345678

PULSSEQPulse SequenceSPGR
SPGR

2023-08-01

3

DMD-

LGE

RT

DU

DMD-RT-01-301

ABC001

3

12345678

FLIPANGLFlip Angle50deg5050deg

2023-08-01

4

DMD-

LGE

RT

DU

DMD-RT-01-301

ABC001

4

12345678

INTDISTM

Interslice Distance

1mm11mm

2023-08-01

5

DMD-

LGE

RT

DU

DMD-RT-01-301

ABC001

5

12345678

STHICKSlice Thickness6mm66mm

2023-08-01

6

DMD-

LGE

RT

DU

DMD-RT-01-301

ABC001

6

12345678

FLDVIEWField of View32X38cm32X3832X38cm

2023-08-01

7

DMD-

LGE

RT

DU

DMD-RT-01-301

ABC001

7

12345678

NUMSLICENumber of Slices12
1212

2023-08-01

8

DMD-

LGE

RT

DU

DMD-RT-01-301

ABC001

8

12345678

COILSTRCoil Strength1.5T1.51.5T

2023-08-01

The RELREC dataset is used to describe the relationship between 2 or more records in different domains. For more information on relating records see SDTMIG v3.4, Section 8.2.

Dataset wrap
Namerelrec
Dataset2

Row

STUDYID

RDOMAIN

USUBJID

IDVAR

IDVARVAL

RELTYPE

RELID

1

DMD-LGERT

PR


PRLNKID


ONE

04

2

DMD-LGERT

CV


CVLNKID


MANY

04

3

DMD-LGERT

AG


AGLNKID


ONE

04