1 Introduction
This document describes the CDISC implementation of the Rising From Floor (RISING FROM FLOOR) instrument.
...
The CDISC Intellectual Property Policy can be found on the CDISC website at: https://www.cdisc.org/about/bylaws.
1.1 Representations and Warranties, Limitations of Liability, and Disclaimers
This document is a supplement to the SDTMIG for Human Clinical Trials and is covered under Appendix F of that document, which describes representations, warranties, limitations of liability, and disclaimers. Please see Appendix F of the SDTMIG for a complete version of this material.
...
Although the United States Food and Drug Administration (US FDA) has provided input with regard to this supplement, this input does not constitute US FDA endorsement of any particular instrument.
2 Copyright Status
CDISC believes this instrument
Jira | ||||||||
---|---|---|---|---|---|---|---|---|
|
Jira | ||||||||
---|---|---|---|---|---|---|---|---|
|
...
McDonald CM, Henricson EK, Abresch RT, et al. The 6-minute walk test and other clinical endpoints in duchenne muscular dystrophy: reliability, concurrent validity, and minimal clinically important differences from a multicenter study. Muscle Nerve. 2013;48(3):357-68. Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-576
3 The FT Domain Model
3.1 Assumptions for FT Domain Model
All assumptions and business rules described in the SDTMIG FT domain are applicable to this supplement. Additional assumptions specific to the RISING FROM FLOOR are listed below.
...
- The numerical value for the time to complete the RISING FROM FLOOR is recorded using ISO 8601 format in FTORRES and FTSTRESC. Because ISO 8601 format is a text format, there are no standard numeric scores or units. The sponsor enters the time on the CRF in minutes and seconds according to their protocol. (e.g., 1 minute 10 seconds is represented in the FT domain in ISO 8601 format as "T1M10SPT1M10S")
For the test grade (where FTTESTCD = "RISEF104"), FTORRES is populated with the text description. The numeric rating is represented in FTSTRESC and FTSTRESN.
If the entire instrument was not done, the first question on the CRF represents the reason the entire instrument was not done. If the reason not done is provided, then FTSTAT = "NOT DONE" and FTREASND is equal to the text written on the form for all the test codes.
If the test was not done due to disease, the record where FTTESTCD = "RISEF101" will have FTORRES and FTSTRESC equal to "No, Due to disease under study" and the test grade (FTTESTCD = "RISEF104") will be represented with a value of 1 = "Unable to walk independently"
.Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-577
- Some items on the RISING FROM FLOOR may be logically skipped
per the instrument instructions. If the test was not done because of disease, FTTESTCD = "RISEF102" and "RISEF103" are not done and are treated as logically skipped items. A record is created in ft.xpt for all items. When an item is considered a logically skipped item, it is represented as follows:Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-578 FTSTAT = "NOT DONE"
FTREASND = "LOGICALLY SKIPPED ITEM"
FTORRES, FTSTRESC, and FTSTRESN are set to null
Terminology:
FTCAT, FTTESTCD, and FTTEST values are included in CDISC Controlled Terminology.
A full list of value sets for result and units fields is provided in Section 4, SDTM Mapping Strategy.
3.2 Example for the RISING FROM FLOOR FT Domain Model
The RISING FROM FLOOR example below shows the terminology used to implement the instrument in the FT domain. This example shows the data for 1 subject collected
at the baseline visit for the RISING FROM FLOOR instrument, and data for 1 subject who did not perform the test. The example uses CDISC Controlled Terminology for FTTESTCD, FTTEST, FTORRESU, FTSTRESU, Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-579
and FTCAT. All original results, matching the CRF item response text, are represented in FTORRES. This result is then represented as a standard numeric score in FTSTRESN and as a standard character representation in FTSTRESC. Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-580
...
Dataset wrap | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
4 SDTM Mapping Strategy
This section is used for reference regarding the CRF data capture and to understand the alignment of the instrument to the SDTM FT domain. It also provides guidance on how the result and unit variables (FTORRES, FTSTRESC, FTSTRESN, FTORRESU, and FTSTRESU)
should be populated. Jira showSummary false server Issue Tracker (JIRA) serverId 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 key QRSSUPP-581
FTTESTCD = "RISEF101" FTTEST = "RISEF1-Was Rising From Floor Performed"
...