Page properties
Title

Kurtzke Expanded Disability Status Scale (EDSS)

CDISC ReferenceClinical Classification Supplement to the Study Data Tabulation Model Implementation Guide for Human Clinical Trials
QRS Short Name

EDSS

QRS Permission StatusPublic Domain
TeamMultiple Sclerosis Standards Team and CDISC Questionnaires, Ratings, and Scales (QRS) Subteam
Supplement Version2.0
StatusDRAFT
Date20222023-09-2907
Notes for ReviewersThis supplement is intended to be used with other CDISC user guides for specific therapeutic/disease areas and follows the CDISC Study Data Tabulation Model Implementation Guide for Human Clinical Trials.

...

DateVersionSummary of Changes

20222023-09-2907

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-382

2.0 Draft
  • This measure was re-evaluated to fit the definition of a clinical classification measure. The domain was changed from the QS to RS domain.
  • The EDSS v2.0 supplement was updated to the wiki Clinical Classifications supplement template.
  • The RSEVAL assumption was removed from this supplement, because it is not captured on the CRF and no assumptions are made on the potential values to include in the example.
    Jira
    showSummaryfalse
    serverIssue Tracker (JIRA)
    serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
    keyQRSSUPP-381

  • The example was reduced from 20 to 16 subjects. The original VISITNUM = 2 was revised to 1 and the RSLOBXFL variable was added to represent a baseline response.
  • The example was updated by adding USUBJID = "P0016" to represent how a missing visit is handled when the instrument was not filled out.
  • Added the description of the relationship
    Jira
    showSummaryfalse
    serverIssue Tracker (JIRA)
    serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
    keyQRSSUPP-485
    between the Kurtzke Expanded Disability Status Scale (EDSS) and Kurtzke Functional Systems Scores (KFSS) instruments are (i.e., intended to be used in conjunction with one another) in section Section 3.1
    Assumptions for theRSDomain Model.
  • Updated the example to include a subjects subject's example of the KFSS responses
    Jira
    showSummaryfalse
    serverIssue Tracker (JIRA)
    serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
    keyQRSSUPP-484
    serving as the source to determine the subjects subject's EDSS score.
2013-10-231.0 Final


© 2022 2023 Clinical Data Interchange Standards Consortium, Inc. All rights reserved. 

1 Introduction

This document describes the CDISC implementation of the Kurtzke Expanded Disability Status Scale (EDSS) instrument.

CDISC did not not modify this questionnaires, ratings, and scales (QRS) instrument to meet Clinical Data Acquisition Standards Harmonization (CDASH) case report form (CRF) standards.

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-383

...

The CDISC Intellectual Property Policy can be found on the CDISC website at: https://www.cdisc.org/about/bylaws.

1.1 Representations and Warranties, Limitations of Liability, and Disclaimers

This document is a supplement to the SDTMIG for Human Clinical Trials and is covered under Appendix F of that document, which describes representations, warranties, limitations of liability, and disclaimers. Please see Appendix F of the SDTMIG for a complete version of this material.

...

Although the United States Food and Drug Administration (US FDA) has provided input with regard to this supplement, this input does not constitute US FDA endorsement of any particular instrument.

2 Copyright Status

CDISC believes this instrument to be in the public domain, but you should perform your own assessment. CDISC has included the EDSS in the CDISC library of QRS data standards supplements. Hence, CDISC developed RSTESTCD and RSTEST for each item based on the actual text on the instrument. There may be many versions of this instrument in the public domain or copyrighted. CDISC has chosen to use this version as the data standard.

...

  • Kurtzke JF. Rating neurologic impairment in multiple sclerosis: An
    Jira
    showSummaryfalse
    serverIssue Tracker (JIRA)
    serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
    keyQRSSUPP-385
    expanded disability status scale (EDSS). Neurology. 1983 Nov;33(11):1444-52. 

3 The RS Domain Model

3.1 Assumptions for the RS Domain Model

All assumptions and business rules described in the SDTMIG RS domain are applicable to this supplement. Additional assumptions specific to the EDSS are listed below.

The EDSS is an ordinal clinical rating scale that is used to measure the disability status of subjects. The item response is a range from 0 to 10 in half-point increments that measures the disability status..

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-726

Jira
serverIssue Tracker (JIRA)
columnIdsissuekey,summary,issuetype,created,updated,duedate,assignee,reporter,priority,status,resolution
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-479

The Kurtzke Expanded Disability Status Scale (EDSS) and Kurtzke Functional Systems Scores (KFSS) instruments are intended to be used in conjunction with one another. The The Kurtzke Expanded Disability Status Scale (EDSS) and Kurtzke Functional Systems Scores (KFSS) instruments are intended to be used in conjunction with one another. The KFSS should first be administered by the evaluator and ; results from this assessment are then applied to determine an EDSS scale score (Kurtzke, 1983). A change in the EDSS should only occur if there has been a change of one or more in theFunctional System (FS)

Jira
serverIssue Tracker (JIRA)
columnIdsissuekey,summary,issuetype,created,updated,duedate,assignee,reporter,priority,status,resolution
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-479
scoresEDSS scale score (Kurtzke, 1983). A change in the EDSS should only occur if there has been a change of 1 or more Functional System (FS). Please review the published Kurtzke Functional Systems Scores (KFSS) for details on the functional system scores. JirashowSummaryfalsefor details.
Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-482

Jira
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-
482
727

  1. The scale points original scores include a numeric rating (0-10) and a definition of what is represented by the rating (e.g., 2.5 = "Minimal disability in two

    Jira
    showSummaryfalse
    serverIssue Tracker (JIRA)
    serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
    keyQRSSUPP-387
    FS
    Jira
    showSummaryfalse
    serverIssue Tracker (JIRA)
    serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
    keyQRSSUPP-386
    ."). For the EDSS, RSORRES is populated with the text description while the numeric rating is represented in the standardized character and numeric result variables RSSTRESC and RSSTRESN.

  2. Three responses to the EDSS ratings exceeded the 200-character limit for the RSORRES variable and needed to be reduced to fewer than 200 characters. Section 4, SDTM Mapping Strategy, indicates which item responses were revised in order to fit the 200-character limit.

  3. Terminology

    1. RSCAT, RSTESTCD, and RSTEST values are included in CDISC Controlled Terminology.

    2. A full list of value sets for the result fields is provided in Section 4, SDTM Mapping Strategy.

3.2 Example for the EDSS RS Domain Model

The EDSS example below shows the terminology used to implement the instrument in the RS domain. This example shows the data for 1 subject collected at the baseline and visit 2

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-388
for the EDSS instrument. The example uses CDISC Controlled Terminology for RSTESTCD, RSTEST, and RSCAT. All original results, matching the CRF item response text, are represented in QSORRES.This result is then represented as a standard numeric score in QSSTRESN and as a standard character representation in QSSTRESC.

...

The KFSS responses are used to determine the EDSS score.determine the EDSS score.

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-488

Dataset wrap
rskfss
Namerskfss
Rowcaps

Rows 12-22: Show the subject was not evaluated on this instrument at visit 2. Since the visit was missed, the reason for not completing the visit was not collected, no date is assumed for when the visit would have occurred.

Dataset2
RowSTUDYIDDOMAINUSUBJIDRSSEQRSTESTCDRSTESTRSCATRSORRESRSSTRESCRSSTRESNRSSTATRSLOBXFLVISITNUMRSDTC
1STUDYXRSP00011KFSS101KFSS1-Pyramidal Functions
Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-728
KFSSMinimal disability22
Y12012-11-16
2STUDYXRSP00012KFSS102KFSS1-Cerebellar FunctionsKFSSMild ataxia22
Y12012-11-16
3STUDYXRSP00013KFSS102AKFSS1-Weakness Interferes With TestingKFSSNOT CHECKEDNOT CHECKED

Y12012-11-16
4STUDYXRSP00014KFSS103KFSS1-Brain Stem FunctionsKFSSNormal00
Y12012-11-16
5STUDYXRSP00015KFSS104KFSS1-Sensory FunctionsKFSSVibration or figure-writing decrease only, in one or two limbs11
Y12012-11-16
6STUDYXRSP00016KFSS105KFSS1-Bowel and Bladder FunctionsKFSSNormal00
Y12012-11-16
7STUDYXRSP00017KFSS106KFSS1-Visual or Optic FunctionsKFSSScotoma with visual acuity (corrected) better than 20/3011
Y12012-11-16
8STUDYXRSP00018KFSS106AKFSS1-Presence of Temporal PallorKFSSCHECKEDCHECKED

Y12012-11-16
9STUDYXRSP00019KFSS107KFSS1-Cerebral or Mental FunctionsKFSSUnknownUnknown

Y12012-11-16
10STUDYXRSP000110KFSS108KFSS1-Other FunctionsKFSSNone00
Y12012-11-16
11STUDYXRSP000111KFSS108AKFSS1-Other Functions SpecifyKFSS


NOT DONEY12012-11-16
12STUDYXRSP000112KFSS101KFSS1-Pyramidal FunctionsKFSS


NOT DONE
22012-12-16
13STUDYXRSP000113KFSS102KFSS1-Cerebellar FunctionsKFSS


NOT DONE
22012-12-16
14STUDYXRSP000114KFSS102AKFSS1-Weakness Interferes With TestingKFSS


NOT DONE
22012-12-16
15STUDYXRSP000115KFSS103KFSS1-Brain Stem FunctionsKFSS


NOT DONE
2
2012-12-1616STUDYXRSP000116KFSS104KFSS1-Sensory FunctionsKFSS


NOT DONE2
22012-12-16
17STUDYXRSP000117KFSS105KFSS1-Bowel and Bladder FunctionsKFSS


NOT DONE
22012-12-16
18STUDYXRSP000118KFSS106KFSS1-Visual or Optic FunctionsKFSS


NOT DONE
22012-12-16
19STUDYXRSP000119KFSS106AKFSS1-Presence of Temporal PallorKFSS


NOT DONE
22012-12-16
20STUDYXRSP000120KFSS107KFSS1-Cerebral or Mental FunctionsKFSS


NOT DONE
22012-12-16
21STUDYXRSP000121KFSS108KFSS1-Other FunctionsKFSS


NOT DONE
22012-12-16
22STUDYXRSP000122KFSS108AKFSS1-Other Functions SpecifyKFSS


NOT DONE
22012-12-16


Dataset wrap
Namersedss
Rowcaps
Row 1:Represent he subjects Represents the subject's EDSS score based on the subjects subject's KFSS visit 1 responses, including 2 FS grade 2 and others either 0 or 1 responses.
Row 2:

Represent Represents that the subject

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-391
that was not evaluated on this instrument at visit 2. Since Because the visit was missed, the reason for not completing the visit was not collected, ; no date is assumed for when the visit would have occurred

Dataset2
RowSTUDYIDDOMAINUSUBJIDRSSEQRSTESTCDRSTESTRSCATRSORRESRSSTRESCRSSTRESNRSSTATRSLOBXFLVISITNUMRSDTC
1STUDYXRSP00011EDSS0101EDSS01-Expanded Disability ScoreEDSSMinimal disability in two FS.2.52.5
Y12012-11-16
2STUDYXRSP00011EDSS0101EDSS01-Expanded Disability ScoreEDSS


NOT DONE

2

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyQRSSUPP-390



4 SDTM Mapping Strategy

This section is used for reference regarding the CRF data capture and to understand the alignment of the instrument to the SDTM RS domain. It also provides guidance on how the result variables (RSORRES, RSSTRESC, and RSSTRESN) should be populated.

...