The associated These SDTM datasets for represent the data collected above are provided below. The An abbreviated Tobacco Product Identifier Identifiers and Descriptors (TO) domain which example is also provided for reference.

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyTOBA-121
TO provides a mechanism for uniquely identifying a tobacco product was used.  Only one and is the source of the SPTOBID variable. For more information on this domain, see Section 3.1.1, Tobacco Product Identifiers and Descriptors. Only 1 tobacco product was of interest in the study. 

Dataset wrap
NameTO
Dataset2
RowSTUDYIDDOMAINSPTOBIDTOSEQTOTESTCDTOPARMCDTOTESTTOPARMTOCATTOORRESTOORRESUTOSTRESCTOSTRESNTOSTRESUTOVAL
1TB123TOVAPE-Z01

1

TBPRDCATTobacco Product CategoryPRODUCT IDENTIFIERENDS (VAPES)ENDS (VAPES)
2TB123TOVAPE-Z012TBPRSCATTobacco Product SubcategoryPRODUCT IDENTIFIERCLOSED E-CIGARETTECLOSED E-CIGARETTE
3TB123TOVAPE-Z013MANUFManufacturerPRODUCT IDENTIFIERXXX VAPES USAXXX VAPES USA

These product issues malfunctions and events are represented in the Tobacco Product Events and Malfunctions Domain ( EM).   Events not specifically associated with the product device should not be represented in this EM domain.     

The sponsor applicant used a standardized or dictionary-derived text for the description of an issue or events. (Note: CDISC does not provide information on prescribe what standardized or dictionary-derived text should be used.). The sponsor applicant decided to use the International Medical Device Regulators Forum (IMDRF) document IMDRF Terminologies for Categorized Adverse Event Reporting (AER): Terms, Terminology Structure and Codes. Annex A ( 2022) provides terminologies for categorized adverse event reporting for the medical problem codes. The name and version of the dictionary used to map terms must be provided in a Define.XML ExternalCodeList element (see Section 2.10, Standards for Data Exchange).

EMDECOD was the Level 3 IMDRF term. Non-standard variables NSVs were used to represent the various coding level variables defined in the dictionary. 

( NOTE: Meta Example to be confirmed with someone - RM. )

Example SUPPEM  Example SUPPEM Variable Metadata

Variable Label Type Codelist
EMIMDRCDIMDRF CodetextIMDRFANNEXA 
EMIMDRFL2IMDRF Level 2textIMDRFANNEXA
EMIMDRFL1IMDRF Level 1textIMDRFANNEXA

...

Codelist

External Dictionary Name

Dictionary Version

Reference

IMDRFANNEXA IMDRF Terminologies for Categorized Adverse Event Reporting (AER): Terms, Terminology Structure and Codes: Annex A 

Release Number: 2022

https://www.imdrf.org/consultations/imdrf-terminologies-categorized-adverse-event-reporting-aer-terms-terminology-structure-and-codes

The SDTM EM dataset is shown below. 

Dataset wrap
NameEM
Dataset2

Row

STUDYID

DOMAIN

USUBJID

SPTOBID

EMSEQ

EMLNKID

EMTERM

EMDECOD

EMMODIFY

EMACNDEV

EMPATT

EMSTDTC

1

TB123

EM

2029

VAPE-Z01

1


Broken Heater

Mechanical Problem

Mechanical Problem

DEVICE REPLACED

SINGLE

2009-12-28

2

TB123

EM

1059

VAPE-Z01

1


Won’t charge

Charging Problem

Charging Problem

BATTERY REPLACED

SINGLE

2009-01-05

3

TB123

EM

3067

VAPE-Z01

1

1

Battery Malfunction

Battery Problem

Battery Problem

BATTERY REPLACED

INTERMITTENT

2009-01-05

Below is the dataset, SUPPEM, The SUPPEM dataset is used to represent the non-standad varibables NSVs used for coding the issue malfunction or event. The parent domain (RDOMAIN) is EM, and IDVAR is EMSEQ. QNAM holds the name of the supplemental qualifier variable being defined. This only shows the data for subject 2029. The data recorded in QVAL applies to the subject’s records, where IDVAR (EMSEQ) equals the value specified in IDVARVAL. 

...

The RELREC dataset was used to record the relationship between the Tobacco Product Events and Malfunctions ( EM ) dataset and any reported AE represented in the AE dataset. 

...