This is a study where subjects were randomized to 3 different concentrations of nicotine e-nicotine liquid, or their usual brand of cigarettes. The subject subjects used the product at home for 2 weeks. This 2-week period allowed subjects to become familiar with the e-cigarette. After two 2 weeks, the subjects were confined to the clinical clinic for one 1 day. They were required to not use any tobacco products for 12 hours prior to the visit. Subjects had to have CO level levels below a pre-specified prespecified level , to attend the visit. If the level , was too high, the visit was re-scheduledrescheduled. Subjects were instructed to take 10 puffs on the e-cigarette/usual brand of cigarettes in the morning and afternoon. Puff topography was measured in the morning and afternoon using the same device for all subjects. Subjects were not allowed to use any tobacco products between the morning and afternoon sessions.
A Device Identifiers (DI), a Study Reference domain, DI, was used to identify the device used to measure puff topography. This provides a consistent sponsor-defined variable (SPDEVID) for linking data. Device Because device identifiers exist independently from subjects; therefore, the DI domain does not contain USUBJID. Only one 1 device was used for all subjects in the study.
Dataset wrap |
---|
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | SPDEVID | DISEQ | DIPARMCD | DIPARM | DIVAL | 1 | TOPT001 | DI | PUFANYXYZ | 1 | DEVTYPE | Device Type | PUFF TOPOGRAPHY ANALYZER | 2 | TOPT001 | DI | PUFANYXYZ | 2 | MODEL | Model | PUFFALYZER 900 | 3 | TOPT001 | DI | PUFANYXYZ | 3 | MANUF | Manufacturer | ACME |
|
|
The sponsor applicant submitted the EX domain to represent the usage Exposure (EX) domain to represent use of the tobacco product. For each subject, the usage Usage for the two 2-week period are is represented , and then for each subject, along with the specified usage use during the in-clinic visit are shown. The sponsor applicant elected not to represent each puff in this EX dataset. Each Puff , although each puff could have been recorded.
Dataset wrap |
---|
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | SPTOBID | EXSEQ | SPTOBID | EXLNKID | EXTRT | EXDOSE | EXDOSTXT | EXDOSU | EXDOSFRM | EXROUTE | EXPSTRG | EXPSTRGU | EXSTDTC | EXENDTC |
---|
1 | TOPT001 | EX | 3001 | 1 | EC-333 | 1 |
| Nicotine e-nicotine liquid |
| AD LIBITUM |
| CARTRIDGE | RESPIRATORY (INHALATION) | 8 | mg/mL | 2020-06-26 | 2020-07-14 | 2 | TOPT001 | EX | 30012 | EC-333 | 2 | 1 | Nicotine e-nicotine liquid | 10 |
| PUFF | CARTRIDGE | RESPIRATORY (INHALATION) | 8 | mg/mL | 2020-07-15T9:00 | 2020-07-15TT9:45 | 3 | TOPT001 | EX | 30013 | EC-333 | 3 | 2 | Nicotine e-nicotine liquid | 10 |
| PUFF | CARTRIDGE | RESPIRATORY (INHALATION) | 8 | mg/mL | 2020-07-15T3:00 | 2020-07-15TT3:45 | 4 | TOPT001 | EX | 4001 | 1 | EC-333 | 1 |
| Nicotine e-nicotine liquid |
| AD LIBITUM |
| CARTRIDGE | RESPIRATORY (INHALATION) | 16 | mg/mL | 2020-09-06 | 2020-09-22 | 5 | TOPT001 | EX | 4001 | 2 | EC-333 | 2 | 1 | Nicotine e-nicotine liquid | 10 |
| PUFF | CARTRIDGE | RESPIRATORY (INHALATION) | 16 | mg/mL | 2020-09-22T9:00 | 2020-09-22T9:30 | 6 | TOPT001 | EX | 4001 | 3 | EC-333 | 3 | 2 | Nicotine e-nicotine liquid | 10 |
| PUFF | CARTRIDGE | RESPIRATORY (INHALATION) | 16 | mg/mL | 2020-09-22T3:00 | 2020-09-22T3:30 | 7 | TOPT001 | EX | 5004 |
| 1 |
| Cigarettes Brand XYZ |
| AD LIBITUM |
| CIGARETTE | RESPIRATORY (INHALATION) | 12.1 | mg/cigarette | 2020-10-08 | 2020-10-22 | 8 | TOPT001 | EX | 5004 |
| 2 | 1 | Cigarettes Brand XYZ | 10 |
| PUFF | CIGARETTE | RESPIRATORY (INHALATION) | 12.1 | mg/cigarette | 2020-10-22T9:00 | 2020-09-22T9:30 | 9 | TOPT0011 | EX | 5004 |
| 3 | 2 | Cigarettes Brand XYZ | 10 |
| PUFF | CIGARETTE | RESPIRATORY (INHALATION) | 12.1 | mg/cigarette | 2020-10-22T3:00 | 2020-09-22T3:30 |
|
|
The FAEX domain was used to represent the puff topography associated with the in-clinic visit. The Findings About Events or Interventions structure ("FA structure") is used to represent collected data that are findings about an event or intervention that cannot be represented within an event or intervention record or as a supplemental qualifier to such a record. Not all findings associated with an event or intervention should be represented in the FA structure.
A puff-by puff analysis was performed. Only selected data for puffs 1 and 10 are shown. No data are shown for 2-9 to simplify dataset review. FATPT was used to represent the time point , (in this case, AM and PM). Typically, the sponsor derives applicants derive summary results using the individual source data records, ; these summary results are represented in ADaM. However, if summary results are collected on a CRF or provided by an external vendor. , these derived results can be represented in FAEX using the variable FACOLSRT. In this example, the sponsor applicant created an ADaM dataset to represent the summary data ( Not Shownnot shown).
Dataset wrap |
---|
|
Jira |
---|
showSummary | false |
---|
server | Issue Tracker (JIRA) |
---|
serverId | 85506ce4-3cb3-3d91-85ee-f633aaaf4a45 |
---|
key | TOBA-288 |
---|
|
Rowcaps |
---|
Rows 1, 6: | Show the Number number of Puffs puffs taken in the time interval specified in FADTC and FAENDTC. This was pre-specified prespecified in the design, but the sponsor applicant reported the actual number of puffs taken. | Rows 2-5: | Show the various measurements recorded for subject 3001 for Puff puff 1 during the morning administration of the tobacco product. FADTC and FAENDTC provides provide the timing of each puff. The individual puff data for the afternoon are not shown. | Rows 67-10: | Show the various measurements recorded for subject 3001 for Puff puff 10 during the afternoon administration of the tobacco product. FADTC and FAENDTC provides provide the timing of each puff. The individual puff data for the morning session are not shown. Note the data : Data for Puffs puffs 2-9 are not shown to save spacesimplify dataset review. | Rows 12-15: | Show the various measurements recorded for subject 4001. Only a few rows are shown to save spacesimplify dataset review. |
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | SPDEVID | SPTOBID | FASEQ | FALNKID | FASPID | FATESTCD | FATEST | FAOBJ | FACAT | FAORRES | FAORRESU | FASTRESC | FASTRESU | VISITNUM | FADTC | FAENDTC | FATPT |
---|
1 | TOPT001 | FA | 3001 | PUFANYXYZ | EC-333 | 1 | 1 |
| PUFF TOT | Total Number of Puffs | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 10 | PUFFS | 10 | PUFFS | 2 | 2020-07-15T09:00 | 2020-07-15TT9:45 | AM | 2 | TOPT001 | FA | 3001 | PUFANYXYZ | EC-333 | 2 | 1 | PUFF 1 | PUFFVOL | Puff Volume | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 36.7 | mL/sec | 37 | mL/sec | 2 | 2020-07-15T09:01.36 | 2020-07-15T09:01.38 | AM | 3 | | FA | 3001 | PUFANYXYZ | EC-333 | 3 | 1 | PUFF 1 | AVGFLOW | Average Flow rate | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 15.5 | mL/sec | 15.5 | mL/sec | 2 | 2020-07-15T09:01.36 | 2020-07-15T09:01.38 | AM | 4 | TOPT001 | FA | 3001 | PUFANYXYZ | EC-333 | 4 | 1 | PUFF 1 | PKFLOW | Peak Flow Rate | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 20.5 | mL/sec | 20.5 | mL/sec | 2 | 2020-07-15T09:01.36 | 2020-07-15T09:01.38 | AM | 5 | TOPT001 | FA | 3001 | PUFANYXYZ | EC-333 | 5 | 1 | PUFF 1 | PUFFDUR | Puff Duration | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 2.0 | msec | 1.6 | msec | 2 | 2020-07-15T09:01.36 | 2020-07-15T09:01.38 | AM | 6 | | FA | 3001 | PUFANYXYZ | EC-333 | 6 | 2 |
| PUFF TOT | Total Number of Puffs | e-nicotin liquid | PUFF TOPOGRAPHY | 9 | PUFFS | 9 | PUFFS | 2 | 2020-07-15T03:00 | 2020-07-15T03:30 | PM | 7 | TOPT001 | FA | 3001 | PUFANYXYZ | EC-333 | 7 | 2 | PUFF 10 | INTPUFIN | Puff Interval | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 910396.8 | sec | 910396.8 | sec | 2 | 2020-07-15T03:30:34 | 2020-07-15T03:30:36 | PM | 8 | TOPT001 | FA | 3001 | PUFANYXYZ | EC-333 | 8 | 2 | PUFF 10 | PUFFVOL | Puff Volume | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 43 | mL/sec | 43 | mL/sec | 2 | 2020-07-15T03:30:34 | 2020-07-15T03:30:36 | PM | 9 | | FA | 3001 | PUFANYXYZ | EC-333 | 9 | 2 | PUFF 10 | AVGFLOW | Average Flow rate | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 14.5 | mL/sec | 14.5 | mL/sec | 2 | 2020-07-15T03:30:34 | 2020-07-15T03:30:36 | PM | 10 | TOPT001 | FA | 3001 | PUFANYXYZ | EC-333 | 10 | 2 | PUFF 10 | PKFLOW | Peak Flow Rate | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 22.5 | mL/sec | 22.5 | mL/sec | 2 | 2020-07-15T03:30:34 | 2020-07-15T03:30:36 | PM | 12 | TOPT001 | FA | 4001 | PUFANYXYZ | EC-333 | 1 | 1 |
| PUFF TOT | Total Number of Puffs | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 10 | PUFFS | 10 | PUFFS | 2 | 2020-08-15T9:00 | 2020-08-15TT9:45 | AM | 13 | | FA | 4001 | PUFANYXYZ | EC-333 | 2 | 1 | PUFF 1 | PUFFVOL | Puff Volume | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 34.7 | mL/sec | 34 | mL/sec | 2 | 2020-08-15T09:01.36 | 2020-08-15T09:01.38 | AM | 14 | TOPT001 | FA | 4001 | PUFANYXYZ | EC-333 | 3 | 1 | PUFF 1 | AVGFLOW | Average Flow rate | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 15.5 | mL/sec | 15.5 | mL/sec | 2 | 2020-08-15T09:01.36 | 2020-08-15T09:01.38 | AM | 15 | TOPT001 | FA | 4001 | PUFANYXYZ | EC-333 | 4 | 1 | PUFF 1 | PKFLOW | Peak Flow Rate | Nicotine e-nicotine liquid | PUFF TOPOGRAPHY | 23.5 | mL/sec | 23.5 | mL/sec | 2 | 2020-08-15T09:01.36 | 2020-08-15T09:01.38 | AM |
|
|
The RELREC dataset was used to record the relationship between the Exposure records in EX and the records in FAEX.
...