This example Procedures (PR) dataset includes the SPDEVID variable to show what device was used and the PRREFID variable to represent the accession number or procedure reference identifier associated with the specific procedure. SPDEVID was used to link this PR record to the device records.

Dataset wrap
Namepr
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

PRSEQ

PRREFID

PRLNKID

PRTRT

PRLOC

PRSTDTC

1

DMD-RT

PR

DMD-RT-01-301

ABC001

1

12345678

04

MRI

HEART

2023-08-01

This example cardiovascular system findings (CV) dataset shows how to represent longitudinal relaxation time, transverse relaxation time, and extracellular volume findings from CMR imaging. This example includes records for an unreadable image and an unperformed test. For these records, CVSTAT was populated with "NOT DONE" and CVREASND was populated with the reason the result was not provided or the procedure was not done. An NSV was used to represent image quality.

Dataset wrap
Namecv
Rowcaps

Rows 1-6:

Show the longitudinal relaxation time and the transverse relaxation time for different segments of the heart prior to contrast (CVTPT = BEFORE and CVTPTREF = CONTRAST ADMINISTRATION).

Rows 7-8:

Show the longitudinal relaxation time and myocardial extracellular volume for the LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT after contrast (CVTPT = AFTER and CVTPTREF = CONTRAST ADMINISTRATION).

Row 9:

Shows an unreadable CMR result for participant DMD-RT-01-302, CVREASND = "NON-EVALUABLE IMAGE".

Row 10:

Shows participant DMD-RT-01-303 did not have a CMR procedure because they were unable to place an intravenous access line, CVREASND = "UNABLE TO PLACE INTRAVENOUS LINE"

"T1 mapping stands for registering the course of recovery of longitudinal magnetism", this means the relaxation time after either the preparation step (saturation or inversion prepulse) followed by the acquisition of images at several time points during the T1 recover/relaxation. T1 value represents the time when recovery of magnetism has reached a percentage of its original state (63%). The recovery rate relates to the myocardial tissue properties that may be altered by pathological tissue presence (https://www.ahajournals.org/doi/10.1161/circresaha.116.307974). T1 mapping values increase with disease, and decrease post contrast.

...

Do we need minimum and maximum values? for SI mean, area, circumference, SI mean, SI min/max?

Do we need timepoints for the T1 measurement or just the point in time of the final assessment?

Does Cardiac Motion correction need to be indicated? If yes, does the type need to be indicated (such as the modified LL (MOLLI) sequence)?  If yes, should this be reflected on each result? (Alana/Jon/Diane - I am considering a "Cardiac Motion Correction Indicator" NSV)

Do we need a postcontrast indicator since those measurement differ? or is that what the terms "native T1" (no contrast) and "post-contrast T1" (after contrast) mean?

Three is a "gold" standard noted as the "T1 mapping based on the acquisition of single images by a T1 turbo spin-echo sequence". It is noted as the ultimate T1 mapping method. Does the method need to be called out by what kind of acquisition sequence was used?

For the location does the intracellular compartment need to be noted? (myocytes, fibroblasts, endothelial cells, smooth muscle cells)

Does the cardiac phase for the specific T1 segment need to be noted? (atrial systole-diastole; isovolumentric contraction-diastole; rapid ejection-systole; reduced ejection-systole; isovolumetric relaxation-diastole; rapid ventricular filling-diastole)

Is it important to record the "MRI scanner type" (Avanto, Siemens; Best, Philips; Acheiva, Philips), the "reception coil" (16-channel; 32-channel), "the T1 mapping sequence" (MOLLI; ShMOLLI)

...

.
Dataset2

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVLNKID

CVTESTCD

CVTEST

CVORRES

CVORRESU

CVSTRESC

CVSTRESN

CVSTRESU

CVSTAT

CVREASND

CVLOC

CVMETHOD

CVLOBFXL

VISITNUM

VISIT

CVTPT

CVTPTREF

CVDTC


CVOIQ

1DMD-RTCVDMD-RT-01-301104T1
LONGITUDINAL RELAXATION TIME
Longitudinal Relaxation Time

1315

ms

1315

1315ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING1

MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION
SCREENING
2023-08-01
EVALUABLE IMAGE
2DMD-RTCVDMD-RT-01-301204T1
LONGITUDINAL RELAXATION TIME
Longitudinal Relaxation Time1166ms11661166ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING1
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION
SCREENING
2023-08-01
EVALUABLE IMAGE
3DMD-RTCVDMD-RT-01-301304T1
LONGITUDINAL RELAXATION TIME
Longitudinal Relaxation Time

980

ms

980

980ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING1
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION
SCREENING
2023-08-01
EVALUABLE IMAGE
4DMD-RTCVDMD-RT-01-301404T2
TRANSVERSE RELAXATION TIME
Transverse Relaxation Time

45

962

ms
962
45
962
45ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING1

MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION
SCREENING
2023-08-01
EVALUABLE IMAGE
5DMD-RTCVDMD-RT-01-301504T2
TRANSVERSE RELAXATION TIME
Transverse Relaxation Time

40

976

ms
976
40
976
40ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING1
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION
SCREENING
2023-08-01
EVALUABLE IMAGE
6DMD-RTCVDMD-RT-01-301604T2
TRANSVERSE RELAXATION TIME
Transverse Relaxation Time

48

985

ms
985
48
985
48ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENT
CARDIAC MAGNETIC RESONANCE IMAGING1
MRI
1VISIT 1BEFORECONTRAST ADMINISTRATION
SCREENING
2023-08-01
EVALUABLE IMAGE
7DMD-RTCVDMD-RT-01-301704
NATIVE
T1
MAPPING1070
Longitudinal Relaxation Time

450

ms
1070
450
1070
450ms
CARDIAC MAGNETIC RESONANCE IMAGING1



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

MRI
1VISIT 1AFTERCONTRAST ADMINISTRATION
SCREENING
2023-08-01
EVALUABLE IMAGE
8DMD-RTCVDMD-RT-01-301804
EXTRAVOLEXTRACELLULAR VOLUME

1.5

/s

1.5

1.5
MYECV

Myocardial Extracellular Volume

25

%2525%
/s



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING1

MRI
1VISIT 1AFTERCONTRAST ADMINISTRATION
SCREENING
2023-08-01
EVALUABLE IMAGE
9DMD-RTCVDMD-RT-01-3021
CVALLCardiovascular System Findings




NOT DONE

NON-EVALUABLE IMAGE

HEART

MRI
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05
NON-EVALUABLE IMAGE
10DMD-RTCVDMD-RT-01-3031
CVALLCardiovascular System Findings




NOT DONE

UNABLE TO PLACE INTRAVENOUS LINE

HEART

MRI
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05

Nsvmeta
DomainCV

Variable

Label

Type

Role

Origin

CVOIQOverall Image QualitytextNon-standard Record QualifierCRF

The example Procedure Agents (AG) dataset shows details for the gadolinium-based contrast used for the procedure.

Dataset wrap
Nameag
Dataset2

Row

STUDYID

DOMAIN

USUBJID

AGSEQ

AGLNKID

AGTRT

AGCAT

AGDOSE

AGDOSU

AGDOSFRM

AGROUTE

AGSTDTC

1

DMD-RT

AG

DMD-RT-01-301

1

04

Gd-DOTA

CONTRAST AGENT

8

mL

SOLUTION

INTRAVENOUS

2023-08-01

The Device Identifiers (DI) domain is used to represent the device information details. Characteristics recorded in a DI dataset are those necessary to identify each device to the level of granularity necessary for the study (e.g., to the model level if knowing the actual unit is not necessary, to the serial number level if there is a need to distinguish among units).

Dataset wrap
Namedi
Dataset2

Row

STUDYID

DOMAIN

SPDEVID

DISEQ

DIPARMCD

DIPARM

DIVAL

1

DMD-RT

DI

ABC001

1

DEVTYPE

Device Type

CMR Scanner

2

DMD-RT

DI

ABC001

2

MANUF

Manufacturer

ACME

3

DMD-RT

DI

ABC001

3

TRADENAM

Trade Name

ACME 64

4

DMD-RT

DI

ABC001

4

MODEL

Model Number

CMR540

Fixed properties of devices are represented in the Device Properties (DO) domain. The sponsor chose to keep the software version constant throughout the study.

Dataset wrap
Namedo
Dataset2
Row

STUDYID

DOMAIN

SPDEVID

DOSEQ

DOTESTCD

DOTEST

DOORRES

DOORRESU

1

DMD-RT

DO

ABC001

1

SFTWRNAM

Software Name

CMRRLXU2


2

DMD-RT

DO

ABC001

2

SFTWRVER

Software Version

CMRLX.2


3

DMD-RT

DO

ABC001

3IMAQDIMImage Acquisition Dimensionality3

Changeable properties and parameters of devices are represented in the Device-in-Use (DU) domain. These settings can be linked to records in the CV dataset by their shared SPDEVID and DTC values. For brevity, only 1 subject's parameters are shown.

SCREENING
Dataset wrap
Namedu
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

DUSEQ

DUREFID

DUTESTCD

DUTEST

DUORRES

DUORRESU

DUSTRESC

DUSTRESN

DUSTRESU

DUDTC

1

DMD-RT

DU

DMD-RT-01-301

ABC001

1

12345678

ANTPLANAnatomical PlaneSAGITTAL
SAGITTAL

2023-08-01

2

DMD-RT

DU

DMD-RT-01-301

ABC001

2

12345678

PULSSEQPulse SequenceSPGR
SPGR

2023-08-01

3

DMD-RT

DU

DMD-RT-01-301

ABC001

3

12345678

FLIPANGLFlip Angle50deg5050deg
3019EXTRAVOLEXTRACELLULAR VOLUME

1.2

/s

1.2

1.2/sLEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING1

2023-08-01

10
4

DMD-RT

DU

DMD-RT-01-301

ABC001

4

12345678

INTDISTM

Interslice Distance

1mm11mm

2023-08-01

5

DMD-RT

DU

DMD-RT-01-301

ABC001

5

12345678

STHICKSlice Thickness6mm66mm

2023-08-01

6

DMD-RT

DU

DMD-RT-01-301

ABC001

6

12345678

FLDVIEWField of View32X38cm32X3832X38cm

2023-08-01

7

DMD-RT

DU

DMD-RT-01-301

ABC001

7

12345678

NUMSLICENumber of Slices12
1212

2023-08-01

8

DMD-RT

DU

DMD-RT-01-301

ABC001

8

12345678

COILSTRCoil Strength1.5T1.51.5T

2023-08-01

The RELREC dataset is used to describe the relationship between 2 or more records in different domains.

2023-08-01
Dataset wrap
Namerelrec
Dataset2

Row

STUDYID

RDOMAIN

USUBJID

IDVAR

IDVARVAL

RELTYPE

RELID

1

DMD-RT

PR


PRLNKID


ONE

04

2

DMD-RT

CV


CVLNKID


MANY

04

3

DMD-RT

AG


AGLNKID


ONE

04

CV30110EXTRAVOLEXTRACELLULAR VOLUME

1.1

/s

1.1

1.1/sLEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING1SCREENING