Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Dataset wrap
Nameeg
Rowcaps
Row 1:Shows a measurement of ventricular rate. 
Row 2:Shows a measurement of PR interval. 
Rows 3-4:These interval measurements were collected in seconds. However, in this submission, the standard unit for these tests was milliseconds, so the results have been converted in EGSTRESC and EGSTRESN.
Row 5:Shows "QTcB Interval, Aggregate". This result was derived by the sponsorapplicant, as indicated by the “Y” in the EGDRVFL column. Note that EGORRES is null for these derived records.
Row 6:Shows the result of the TEST "Interpretation" (i.e., the interpretation of the ECG strip as a whole), which for this ECG was "ABNORMAL". This result was assessed as clinically significant (EGCLSIG = "Y").
Dataset2
RowSTUDYIDDOMAINUSUBJIDEGSEQEGREFIDEGTESTCDEGTESTEGCATEGPOSEGORRESEGORRESUEGSTRESCEGSTRESNEGSTRESUEGNAMEGMETHODEGDRVFLEGCLSIGVISITNUMVISITEGDTCEGDY
1XYZEGXYZ-US-701-0021334PT89EGHRMNECG Mean Heart RateMEASUREMENTSUPINE62beats/min6262beats/minTest Lab12 LEAD STANDARD

1SCREENING2003-04-15T11:58-36
2XYZEGXYZ-US-701-0022334PT89PRAGPR Interval, AggregateINTERVALSUPINE0.15sec150150msecTest Lab12 LEAD STANDARD

1SCREENING2003-04-15T11:58-36
3XYZEGXYZ-US-701-0023334PT89QRSAGQRS Duration, AggregateINTERVALSUPINE0.103sec103103msecTest Lab12 LEAD STANDARD

1SCREENING2003-04-15T11:58-36
4XYZEGXYZ-US-701-0024334PT89QTAGQT Interval, AggregateINTERVALSUPINE0.406sec406406msecTest Lab12 LEAD STANDARD

1SCREENING2003-04-15T11:58-36
5XYZEGXYZ-US-701-0025334PT89QTCAQTcA Interval, AggregateINTERVALSUPINE

469469msecTest Lab12 LEAD STANDARDY
1SCREENING2003-04-15T11:58-36
6XYZEGXYZ-US-701-00212334PT89INTPInterpretation
SUPINEABNORMAL
ABNORMAL




Y1SCREENING2003-04-15T11:58-36