Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The following example shows parametric mapping (T1, T2, and extracellular volume) results. For brevity, a limited sample of tests after contrast are shown in this example.The example includes the representation of some device information (i.e., device manufacturer, software, version information, and the specific settings for each subject. Study requirements determine what data is needed. This example shows what device is used (SPDEVID) and the procedures (PR) dataset includes the SPDEVID variable to show what device was used and the PRREFID variable to represent the accession number or procedure reference identifier (PRREFID) associated with the specific procedure for subject DMD-RT-01-301. The SPDEVID variable is was used to relate link this procedures ( PR ) dataset record to other the device records below.

Dataset wrap
Namepr
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

PRSEQ

PRREFID

PRLNKID

PRTRT

PRSTDTC

1

DMD-RT

PR

DMD-RT-01-301

ABC001

1

12345678

04

CARDIAC MAGNETIC RESONANCE IMAGING

2023-08-01

The example cardiovascular system findings (CV) dataset below shows how to represent longitudinal relaxation time, transverse relaxation time and extracellular volume findings from CMR. This example includes records for an unreadable image and an unperformed test. For these records, CVSTAT was populated with "NOT DONE" and CVREASND was populated with the reason the result was not provided or the procedure was not done. A non-standard variable is was used to represent image quality.

Dataset wrap
Namecv
Rowcaps

Rows 1-6:

Show the longitudinal relaxation time and the transverse relaxation time for different segments of the heart prior to contrast (CVTPT = BEFORE and CVTPTREF = CONTRAST ADMINISTRATION).

Rows 7-8:

Show the longitudinal relaxation time and myocardial extracellular volume for different segments of the heart after contrast (CVTPT = AFTER and CVTPTREF = CONTRAST ADMINISTRATION).

Row 9:

Shows an unreadable CMR result for participant DMD-RT-01-302, CVREASND = "NON-EVALUABLE IMAGE".

Row 10:

Shows participant DMD-RT-01-303 did not have a CMR procedure because they were unable to place an intravenous access line, CVREASND = "UNABLE TO PLACE INTRAVENOUS LINE".
Dataset2

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVLNKID

CVTESTCD

CVTEST

CVORRES

CVORRESU

CVSTRESC

CVSTRESN

CVSTRESU

CVSTAT

CVREASND

CVLOC

CVMETHOD

CVLOBFXL

VISITNUM

VISIT

CVTPT

CVTPTREF

CVDTC


CVOIQ

1DMD-RTCVDMD-RT-01-301104T1LONGITUDINAL RELAXATION TIME (T1 TIME)

1315

ms

1315

1315ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
2DMD-RTCVDMD-RT-01-301204T1LONGITUDINAL RELAXATION TIME (T1 TIME)1166ms11661166ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
3DMD-RTCVDMD-RT-01-301304T1LONGITUDINAL RELAXATION TIME (T1 TIME)

980

ms

980

980ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
4DMD-RTCVDMD-RT-01-301404T2TRANSVERSE RELAXATION TIME (T2 TIME)

45

ms4545ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
5DMD-RTCVDMD-RT-01-301504T2TRANSVERSE RELAXATION TIME (T2 TIME)

40

ms4040ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
6DMD-RTCVDMD-RT-01-301604T2TRANSVERSE RELAXATION TIME (T2 TIME)

48

ms4848ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
7DMD-RTCVDMD-RT-01-301704T1LONGITUDINAL RELAXATION TIME (T1 TIME)

450

ms450450ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1AFTERCONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
8DMD-RTCVDMD-RT-01-301804MYECV

MYOCARDIAL EXTRACELLULAR VOLUME

25

%2525%



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1AFTERCONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
9DMD-RTCVDMD-RT-01-3021
CVALLCARDIOVASCULAR SYSTEM FINDINGS




NOT DONE

NON-EVALUABLE IMAGE

HEART

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05
NON-EVALUABLE IMAGE
10DMD-RTCVDMD-RT-01-3031
CVALLCARDIOVASCULAR SYSTEM FINDINGS




NOT DONE

UNABLE TO PLACE INTRAVENOUS LINE

HEART

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05

Nsvmeta
DomainCV

Variable

Label

Type

Role

Origin

CVOIQOverall Image QualitytextNon-standard Record QualifierCRF

...

Dataset wrap
Nameag
Dataset2

Row

STUDYID

DOMAIN

USUBJID

AGSEQ

AGLNKID

AGTRT

AGCAT

AGDOSE

AGDOSU

AGDOSFRM

AGROUTE

AGSTDTC

1

DMD-RT

AG

DMD-RT-01-301

1

04

Gd-DOTA

CONTRAST AGENT

8

mL

SOLUTION

INTRAVENOUS

2023-08-01

...