The example includes the representation of some device information (i.e., device manufacturer, software, version information, and the specific settings for each subject. Study requirements determine what data is needed. The device identifier is represented using SPDEVID and PRREFID. This information shows what device is used and the accession number or procedure reference identifier associated with the specific procedure for subject DMD-RT-01-301. The SPDEVID variable is used to relate this procedures (PR dataset ) dataset to other records by the device (in this case, the CMR machine).

Dataset wrap
Namepr
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

PRSEQ

PRREFID

PRLNKID

PRTRT

PRSTDTC

1

DMD-RT

PR

DMD-RT-01-301

ABC001

1

12345678

04

CARDIAC MAGNETIC RESONANCE IMAGING

2023-08-01

The example cardiovascular system findings (CV) dataset below shows how to represent longitudinal relaxation time, transverse relaxation time and extracellular volume findings from CMR. The timing of the contrast specificity is documented using the CVTPT = BEFORE or AFTER contrast administration. This example includes records for an unreadable image and an unperformed test. CVSTAT was populated with "NOT DONE" and CVREASND was populated with the reason the result was not provided or the procedure was not done. A non-standard variable is used to represent image quality.

Dataset wrap
Namecv
Rowcaps

Rows 1-6:

Show the longitudinal relaxation time and the transverse relaxation time for different segments of the heart prior to contrast.

Rows 7-8:

Show the longitudinal relaxation time and myocardial extracellular volume for different segments of the heart after contrast.

Row 9:

Shows an unreadable CMR result for participant DMD-RT-01-302, CVREASND = "NON-EVALUABLE IMAGE".

Row 10:

Shows participant DMD-RT-01-303 did not have a CMR procedure because they were unable to place an intravenous access line, CVREASND = "UNABLE TO PLACE INTRAVENOUS LINE".
Dataset2

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVTESTCD

CVTEST

CVORRES

CVORRESU

CVSTRESC

CVSTRESN

CVSTRESU

CVSTAT

CVREASND

CVLOC

CVMETHOD

CVLOBFXL

VISITNUM

VISIT

CVTPT

CVTPTREF

CVDTC


CVOIQ

1DMD-RTCVDMD-RT-01-3011T1LONGITUDINAL RELAXATION TIME (T1 TIME)

1315

ms

1315

1315ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
2DMD-RTCVDMD-RT-01-3012T1LONGITUDINAL RELAXATION TIME (T1 TIME)1166ms11661166ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
3DMD-RTCVDMD-RT-01-3013T1LONGITUDINAL RELAXATION TIME (T1 TIME)

980

ms

980

980ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
4DMD-RTCVDMD-RT-01-3014T2TRANSVERSE RELAXATION TIME (T2 TIME)

45

ms4545ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
5DMD-RTCVDMD-RT-01-3015T2TRANSVERSE RELAXATION TIME (T2 TIME)

40

ms4040ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
6DMD-RTCVDMD-RT-01-3016T2TRANSVERSE RELAXATION TIME (T2 TIME)

48

ms4848ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1BEFORECONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
7DMD-RTCVDMD-RT-01-3017T1LONGITUDINAL RELAXATION TIME (T1 TIME)

450

ms450450ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1AFTERCONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
8DMD-RTCVDMD-RT-01-3018MYECV

MYOCARDIAL EXTRACELLULAR VOLUME

25

%2525%



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1AFTERCONTRAST ADMINISTRATION2023-08-01
EVALUABLE IMAGE
9DMD-RTCVDMD-RT-01-3021CVALLCARDIOVASCULAR SYSTEM FINDINGS




NOT DONE

NON-EVALUABLE IMAGE

HEART

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05
NON-EVALUABLE IMAGE
10DMD-RTCVDMD-RT-01-3031CVALLCARDIOVASCULAR SYSTEM FINDINGS




NOT DONE

UNABLE TO PLACE INTRAVENOUS LINE

HEART

CARDIAC MAGNETIC RESONANCE IMAGING
1VISIT 1
CONTRAST ADMINISTRATION2023-08-05

Nsvmeta
DomainCV

Variable

Label

Type

Role

Origin

CVOIQOverall Image QualitytextNon-standard Record QualifierCRF

The example procedure agents (AG) dataset shows details for the gadolinium based contrast used for the procedure.

...