Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. The original scores include a numeric rating (0-100) in increments of 10, and a definition of what the ratings represent at the scale extremes (e.g., 0 = "Strongly Disagree" and 100 = "Strongly Agree"). For the QRS QSU-BRIEF, QSORRES is populated with the text description while the numeric rating is represented in the standardized character and numeric result variables QSSTRESC and QSSTRESN. 

  2. Numeric rating scales used within a questionnaire with a range of text and numeric values are indicated in the SUPPQS domain with:

    QNAM="QSANTXLO"     QNAM="QSANTXHI"

    QNAM="QSANVLLO"     QNAM="QSANVLHI"
    By storing this information in SUPPQS, it is available for interpretation purposes.
    The low and high anchor text is stored in QSORRES with the numeric values stored in QSSTRESC and QSSTRESN.  All other numeric values are stored in QSORRES, QSSTRESC and QSSTRESN.
  3. The time period of evaluation for the QRS QSU-BRIEF is populated in the QSEVINTX field as an evaluation interval text value, since it cannot be precisely described as an ISO 8601 duration. The evaluation interval for the QRS QSU-BRIEF is "DURING QUESTIONNAIRE COMPLETION" (QSEVINTX = "DURING QUESTIONNAIRE COMPLETION").
  4. Records are created in qs.xpt for every instrument item
    1. For items with no data, QSORRES, QSSTRESC, and QSSTRESN are all missing and QSSTAT = "NOT DONE". If the reason is known then that reason is represented in QSREASND (e.g., QSREASND = "PREFER NOT TO ANSWER"). If the reason is unknown, then QSSTAT = "NOT DONE" and QSREASND is missing.

    2. Due to the variability of copyright holder and public domain derived subscore and overall score generation processes, records are not included for derived subscores or overall scores that are not provided.
  5. If the instrument standards currently being developed includes conditionally branched items, insert: Some items on the QRS Short_Name may be conditionally branched per the instrument instructions. Only one of the 2 oxygen saturation scales (RSTESTCD = "NEWS102" or "NEWS103") is completed for each subject. The other will be treated as a conditionally branched item. In addition, item RSTESTCD = "NEWS104A" is only completed when the response to RSTESTCD = "NEWS104" is the amount of oxygen received (in L/min). A record is created in rs.xpt for all items. When an item is considered a conditionally branched item, it is represented as follows:

    When assigned with conditionally branched responses are not documented in the instrument’s instructions or a user manual:

    1. QNAM = “QSCBRFL”, QLABEL = “Conditional Branched Item Flag“, QVAL = “Y” (this is a QS supplemental qualifier variable related to the record).
    2. QSORRES, QSSTRESC, and QSSTRESN are set to null (missing).

    When assigned conditionally branched responses are documented in instructions or a user manual:

    1. QNAM = “QSCBRFL”, QLABEL = “Conditional Branched Item Flag“, QVAL = “Y” (this is a QS supplemental qualifier variable).
    2. The QSORRES responses are represented as follows:
      1. For severity items, QSORRES = "None".
      2. For interference items, QSORRES = "Not at all".
    3. If numeric response values are assigned, they are represented here: QSSTRESC = 0 and QSSTRESN = 0.

       or if no numeric responses are assigned: QSSTRESC = NULL and QSSTRESN = NULL.

  6. Include this point if overall score(s) are submitted to SDTM. Update blue text: The QRS Short_Name instrument includes an overall score (and subscores or other scores as needed.  If so, change "that is" to "that are") that is considered as captured data on the instrument and is not considered as derived in the example below. These scores may be submitted in SDTM or derived in the Analysis Data Model (ADaM) per scoring instructions from [Insert copyright holder's name or other source.].

    1. Subscores and overall scores are represented in--ORRES, --STRESC, and --STRESN.
    2. If subscores or overall scores are received or derived by the sponsor, it is recommended that they are submitted to SDTM and verified in ADaM whenever feasible. It is the sponsors repsonsibility to do this verification based on the instrument's user manual or instructions from the copyright owner.
  7. Please review the decision on not including –EVAL and --EVALID in the QRS Supplement Best Practices topic “--EVAL/–EVALID not included in QRS domains/datasets”.Now we only represent administrative information if it is explicitly collected on an instrument. No assumptions are made for this data; if it's not on the instrument, it's not in the data.

    The SUPPQUAL variables used are a series of non-standard variables that represent collected administrator information, administration device, etc., and these updated SUPPQUAL variables are included in the WIKI non-standard variable registry (Non-standard Variable Registry). For example:

    1. PPRAID which is "Preprinted Administrator Identifier".
    2. COLAVL which is "Collected Administrator Value".

    The supplement version 1.0 of the FAS-NACC UDS V3.0 instrument shows an implementation example.

    The QRS Short_Name instrument collects administrative information as the preprinted examiner’s initials and the collected response. This is represented in the SUPPQUAL variable QNAM = --PPRAID” with QNAM = “Preprinted Administrator Identifier” and QVAL = “EXAMINER’S INITIALS”. The collected initials response is represented with QNAM = “--COLAID” and QNAM = “Collected Administrator Identifier” and QVAL = “ADM1”.

    This is part of the data example for the SUPPQUAL variables.

    The SUPPRS table represents the preprinted and collected administrative items represented on the CRF. 

     supprs.xpt

    STUDYID

    RDOMAIN

    USUBJID

    IDVAR

    IDVARVAL

    QNAM

    QLABEL

    QVAL

    QORIG

    STUDYX

    RS

    100-10001

    RSCAT

    FAS-NACC UDS V3.0

    RSPPRAID

    Preprinted Administrator Identifier

    EXAMINER'S INITIALS

    CRF

    STUDYX

    RS

    100-10001

    RSCAT

    FAS-NACC UDS V3.0

    RSCOLAID

    Collected Administrator Identifier

    ADM1

    CRF

  8. Include this point if there are comments at the end of the instrument. Remove this point if it does not apply.: Comments located at the end of the QRS Short_Name will be recorded in the Comments domain (CO). All assumptions and business rules described in the SDTMIG CO domain are applicable.

  9. Include this point if there are responses over 200 characters. Remove this point if it does not apply: Some responses to the QRS Short_Name items exceeded the 200-character limit for the QSORRES variable and needed to be reduced to fewer than 200 characters. Section 4, SDTM Mapping Strategy, indicates which item responses were revised in order to fit the 200-character limit.

  10. Terminology

    1. QSCAT, QSTESTCD, QSTEST, QSORRES, QSSTRESC, and QSSTRESN (and other variables such as QSORRESU as needed; only include QSORRES, QSSTRESC, and QSSTRESN if the responses are published in CT with public domains instruments) values are included in CDISC Controlled Terminology.

    2. A full list of value sets for the qualifier, timing, resultand unit fields is provided in Section 4, SDTM Mapping Strategy. (Note: Only the result field is always used. Include qualifier, timing, and unit fields as needed and remove this note.)

...