The PR dataset shows the procedure of cardiac magnetic resonance imaging using the device associated with SPDEVID ABC001 and the PRREFID of 12345678. This information shows what CMR device is used for the procedure and the accession number or procedure reference identifier associated with the specific procedure for USUBJID 301. The SPDEVID variable is used to relate records by the device (in this case, the CMR machine).
Dataset wrap |
---|
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | SPDEVID | PRSEQ | PRREFID | PRLNKID | PRTRT | PRSTDTC |
---|
1 | DMD-RT | PR | 301 | ABC001 | 1 | 12345678 | 04 | CARDIAC MAGNETIC RESONANCE IMAGING | 2023-08-01 |
|
|
Dataset wrap |
---|
|
Rowcaps |
---|
Rows 1-10: | Show the T1 Longitudinal Relaxation Time, the T2 Transverse Relaxation Time, Native T1 Mapping, and Extracellular volume for different segments of the heart prior to contrast for CMR. | Rows 11-13: | Show the T1 Longitudinal Relaxation Time, Native T1 Mapping, and Extracellular volume for different segments of the heart after contrast for CMR. |
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | CVSEQ | CVTESTCD | CVTEST | CVCAT | CVORRES | CVORRESU | CVSTRESC | CVSTRESN | CVSTRESU | CVSTAT | CVREASND | CVLOC | CVMETHOD | CVLOBFXL | VISITNUM | VISIT | CVDTC |
| CVICNOIS | CVICMOTD | CVFOIND | CVOIQ |
---|
1 | DMD-RT | CV | 301 | 1 | T1 | LONGITUDINAL RELAXATION TIME | | | ms | | 1315 | ms | | | LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 2 | DMD-RT | CV | 301 | 2 | T1 | LONGITUDINAL RELAXATION TIME | Pre-contrast | 1166 | ms | 1166 | 1166 | ms |
|
| LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 3 | DMD-RT | CV | 301 | 3 | T1 | LONGITUDINAL RELAXATION TIME | | | ms | | 980 | ms |
|
| LEFT VENTRICULAR BASAL INFERIOR SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 4 | DMD-RT | CV | 301 | 4 | T2 | TRANSVERSE RELAXATION TIME | | | ms | 45 | 45 | ms | | | LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 5 | DMD-RT | CV | 301 | 5 | T2 | TRANSVERSE RELAXATION TIME | | | ms | 40 | 40 | ms |
|
| LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 6 | DMD-RT | CV | 301 | 6 | T2 | TRANSVERSE RELAXATION TIME | | | ms | 48 | 48 | ms |
|
| LEFT VENTRICULAR BASAL INFERIOR SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 7 | DMD-RT | CV | 301 | 7 |
| NATIVE T1 MAPPING | Pre-contrast | 1070 | ms | | 1070 | ms |
|
|
| CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | NON-EVALUABLE IMAGE | 8 | DMD-RT | CV | 301 | 8 | EXTRAVOL | EXTRACELLULAR VOLUME | | | /s | | 1.5 | /s | | | LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 9 | DMD-RT | CV | 301 | 9 | EXTRAVOL | EXTRACELLULAR VOLUME | | | /s | | 1.2 | /s |
|
| LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 10 | DMD-RT | CV | 301 | 10 | EXTRAVOL | EXTRACELLULAR VOLUME | | | /s | | 1.1 | /s |
|
| LEFT VENTRICULAR BASAL INFERIOR SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 11 | DMD-RT | CV | 301 | 11 | T1 | LONGITUDINAL RELAXATION TIME | | | ms | 450 | 450 | ms | | | LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 12 | DMD-RT | CV | 301 | 12 |
| NATIVE T1 MAPPING | Post-contrast | 840 | ms | | 840 | ms |
|
|
| CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 13 | DMD-RT | CV | 301 | 13 | EXTRAVOL | EXTRACELLULAR VOLUME | | | % | 25 | 25 | % | | | LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-01 |
| LOW NOISE | NO MOTION DISTORTION | NO FOREIGN OBJECTS | EVALUABLE IMAGE | 1 | DMD-RT | CV | 302 | 1 | CVALL | CMR TEST RESULTS | |
|
|
|
|
| | | | CARDIAC MAGNETIC RESONANCE IMAGING |
| 1 | SCREENING | 2023-08-05 |
| HIGH NOISE | YES-NOT ACCEPTABLE MOTION DISTORTION | YES FOREIGN OBJECTS | NON-EVALUABLE IMAGE |
|
Nsvmeta |
---|
| Variable | Label | Type | Role | Origin |
---|
CVICNOIS | Image Condition r/t Noise | text | Non-standard Record Qualifier | CRF | CVICMOTD | Image Condition r/t Motion Distortion | text | Non-standard Record Qualifier | CRF | CVFOIIND | Foreign Object on Image Indicator | text | Non-standard Record Qualifier | CRF | CVOIQ | Overall Image Quality | text | Non-standard Record Qualifier | CRF |
|
|
The AG dataset shows the Gadolinium based contrast that was used for the procedure. In this example, the researchers did not collect the time of the contrast.
...
Dataset wrap |
---|
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | SPDEVID | DUSEQ | DUREFID | DUTESTCD | DUTEST | DUORRES | DUORRESU | DUSTRESC | DUSTRESN | DUSTRESU | DUDTC |
---|
1 | DMD-LGE | DU | 301 | ABC001 | 1 | 12345678 | ANTPLANE | Anatomical Plane | SAGITTAL |
| SAGITTAL |
|
| 2020-02-21 | 2 | DMD-LGE | DU | 301 | ABC001 | 2 | 12345678 | INTDISTM | | 1 | mm | 1 | 1 | mm | 2020-02-21 | 3 | DMD-LGE | DU | 301 | ABC001 | 3 | 12345678 | STHICK | Slice Thickness | 1 | mm | 1 | 1 | mm | 2020-02-21 | 4 | DMD-LGE | DU | 301 | ABC001 | 4 | 12345678 | PIXSPCX | X-axis Pixel Spacing | 2 | mm | 2 | 2 | mm | 2020-02-21 | 5 | DMD-LGE | DU | 301 | ABC001 | 5 | 12345678 | PIXSPCY | Y-axis Pixel Spacing | 2 | mm | 2 | 2 | mm | 2020-02-21 | 6 | DMD-LGE | DU | 301 | ABC001 | 6 | 12345678 | AQMTRXSZ | Image Acquisition Matrix Size | 256X256 | VOXEL | 256X256 | 256X256 | VOXEL | 2020-02-21 | 7 | DMD-LGE | DU | 301 | ABC001 | 7 | 12345678 | FLDVIEW | Field of View | 280X280 | mm | 280X280 | 280X280 | mm | 2020-02-21 | 8 | DMD-LGE | DU | 301 | ABC001 | 8 | 12345678 | NUMSLICE | Number of Slices | 125 |
| 125 | 125 |
| 2020-02-21 | 9 | DMD-LGE | DU | 301 | ABC001 | 9 | 12345678 | ATTCRCT | Attenuation Correction Type | FBP |
| FBP |
|
| 2020-02-21 | 10 | DMD-LGE | DU | 301 | ABC001 | 10 | 12345678 | DECCORR | Decay Correction Indicator | N |
| N |
|
| 2020-02-21 | 11 | DMD-LGE | DU | 301 | ABC001 | 11 | 12345678 | RANDCORR | Randoms Correction Indicator | N |
| N |
|
| 2020-02-21 | 12 | DMD-LGE | DU | 301 | ABC001 | 12 | 12345678 | RECONDAT | Reconstruction of Raw Data Type | ITERATIVE |
| ITERATIVE |
|
| 2020-02-21 |
|
|
The RELREC dataset is used to describe the relationship between 2 or more records in different domains. For more information on relating records see SDTMIG v3.4, Section 8.2.
Dataset wrap |
---|
|
Dataset2 |
---|
Row | STUDYID | RDOMAIN | USUBJID | IDVAR | IDVARVAL | RELTYPE | RELID |
---|
1 | DMD-LGE | PR |
| PRLNKID |
| ONE | 04 | 2 | DMD-LGE | CV |
| CVLNKID |
| MANY | 04 | 3 | DMD-LGE | AG |
| AGLNKID |
| ONE | 04 |
|
|