Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The PR dataset shows the procedure of cardiac magnetic resonance imaging using the device associated with SPDEVID ABC001 and the PRREFID of 12345678. This information shows what CMR device is used for the procedure and the accession number or procedure reference identifier associated with the specific procedure for USUBJID 301. The SPDEVID variable is used to relate records by the device (in this case, the CMR machine).

Dataset wrap
Namepr
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

PRSEQ

PRREFID

PRLNKID

PRTRT

PRSTDTC

1

DMD-RT

PR

301

ABC001

1

12345678

04

CARDIAC MAGNETIC RESONANCE IMAGING

2023-08-01

Dataset wrap
Namecv
Rowcaps

Rows 1-10:

Show the T1 Longitudinal Relaxation Time, the T2 Transverse Relaxation Time, Native T1 Mapping, and Extracellular volume for different segments of the heart prior to contrast for CMR.

Rows 11-13:

Show the T1 Longitudinal Relaxation Time, Native T1 Mapping, and Extracellular volume for different segments of the heart after contrast for CMR.
Dataset2

Row

STUDYID

DOMAIN

USUBJID

CVSEQ

CVTESTCD

CVTEST

CVCAT

CVORRES

CVORRESU

CVSTRESC

CVSTRESN

CVSTRESU

CVSTAT

CVREASND

CVLOC

CVMETHOD

CVLOBFXL

VISITNUM

VISIT

CVDTC


CVICNOIS

CVICMOTD

CVFOIND

CVOIQ

1DMD-RTCV3011T1LONGITUDINAL RELAXATION TIME

Pre-contrast

1315

ms

1315

1315ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
2DMD-RTCV3012T1LONGITUDINAL RELAXATION TIMEPre-contrast1166ms11661166ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
3DMD-RTCV3013T1LONGITUDINAL RELAXATION TIME

Pre-contrast

980

ms

980

980ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
4DMD-RTCV3014T2TRANSVERSE RELAXATION TIME

Pre-contrast

45

ms4545ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
5DMD-RTCV3015T2TRANSVERSE RELAXATION TIME

Pre-contrast

40

ms4040ms

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
6DMD-RTCV3016T2TRANSVERSE RELAXATION TIME

Pre-contrast

48

ms4848ms

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
7DMD-RTCV3017
NATIVE T1 MAPPINGPre-contrast1070ms

1070

1070ms


CARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSNON-EVALUABLE IMAGE
8DMD-RTCV3018EXTRAVOLEXTRACELLULAR VOLUME

Pre-contrast

1.5

/s

1.5

1.5/s



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
9DMD-RTCV3019EXTRAVOLEXTRACELLULAR VOLUME

Pre-contrast

1.2

/s

1.2

1.2/s

LEFT VENTRICULAR BASAL INFEROSEPTAL SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
10DMD-RTCV30110EXTRAVOLEXTRACELLULAR VOLUME

Pre-contrast

1.1

/s

1.1

1.1/s

LEFT VENTRICULAR BASAL INFERIOR SEGMENTCARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
11DMD-RTCV30111T1LONGITUDINAL RELAXATION TIME

Post-contrast

450

ms450450ms



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
12DMD-RTCV30112
NATIVE T1 MAPPINGPost-contrast840ms

840

840ms


CARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
13DMD-RTCV30113EXTRAVOLEXTRACELLULAR VOLUME

Post-contrast

25

%2525%



LEFT VENTRICULAR BASAL ANTEROSEPTAL SEGMENT

CARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-01
LOW NOISENO MOTION DISTORTIONNO FOREIGN OBJECTSEVALUABLE IMAGE
1DMD-RTCV3021CVALLCMR TEST RESULTS







NOT DONE

NON-EVALUABLE IMAGE

HEART

CARDIAC MAGNETIC RESONANCE IMAGING
1SCREENING2023-08-05
HIGH NOISEYES-NOT ACCEPTABLE MOTION DISTORTIONYES FOREIGN OBJECTSNON-EVALUABLE IMAGE
Nsvmeta
DomainCV

Variable

Label

Type

Role

Origin

CVICNOIS

Image Condition r/t Noise

textNon-standard Record QualifierCRF
CVICMOTDImage Condition r/t Motion DistortiontextNon-standard Record QualifierCRF
CVFOIINDForeign Object on Image IndicatortextNon-standard Record QualifierCRF
CVOIQOverall Image QualitytextNon-standard Record QualifierCRF

The AG dataset shows the Gadolinium based contrast that was used for the procedure. In this example, the researchers did not collect the time of the contrast.

...

Dataset wrap
Namedu
Dataset2
Row

STUDYID

DOMAIN

USUBJID

SPDEVID

DUSEQ

DUREFID

DUTESTCD

DUTEST

DUORRES

DUORRESU

DUSTRESC

DUSTRESN

DUSTRESU

DUDTC

1

DMD-LGE

DU

301

ABC001

1

12345678

ANTPLANEAnatomical PlaneSAGITTAL
SAGITTAL

2020-02-21

2

DMD-LGE

DU

301

ABC001

2

12345678

INTDISTM

Interslice Distance

1mm11mm

2020-02-21

3

DMD-LGE

DU

301

ABC001

3

12345678

STHICKSlice Thickness1mm11mm

2020-02-21

4

DMD-LGE

DU

301

ABC001

4

12345678

PIXSPCXX-axis Pixel Spacing2mm22mm

2020-02-21

5

DMD-LGE

DU

301

ABC001

5

12345678

PIXSPCYY-axis Pixel Spacing2mm22mm

2020-02-21

6

DMD-LGE

DU

301

ABC001

6

12345678

AQMTRXSZImage Acquisition Matrix Size256X256VOXEL256X256256X256VOXEL

2020-02-21

7

DMD-LGE

DU

301

ABC001

7

12345678

FLDVIEWField of View280X280mm280X280280X280mm

2020-02-21

8

DMD-LGE

DU

301

ABC001

8

12345678

NUMSLICENumber of Slices125
125125

2020-02-21

9

DMD-LGE

DU

301

ABC001

9

12345678

ATTCRCTAttenuation Correction TypeFBP
FBP

2020-02-21

10

DMD-LGE

DU

301

ABC001

10

12345678

DECCORRDecay Correction IndicatorN
N

2020-02-21

11

DMD-LGE

DU

301

ABC001

11

12345678

RANDCORRRandoms Correction IndicatorN
N

2020-02-21

12

DMD-LGE

DU

301

ABC001

12

12345678

RECONDATReconstruction of Raw Data TypeITERATIVE
ITERATIVE

2020-02-21

The RELREC dataset is used to describe the relationship between 2 or more records in different domains. For more information on relating records see SDTMIG v3.4, Section 8.2.

Dataset wrap
Namerelrec
Dataset2

Row

STUDYID

RDOMAIN

USUBJID

IDVAR

IDVARVAL

RELTYPE

RELID

1

DMD-LGE

PR


PRLNKID


ONE

04

2

DMD-LGE

CV


CVLNKID


MANY

04

3

DMD-LGE

AG


AGLNKID


ONE

04