Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Dataset wrap
Namepd

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyTOBA-82

Dataset2
RowSTUDYIDDOMAINSPTOBIDPDSEQPDPARMCDPDPARMPDVALTRGPDVALMINPDVALMAXPDVALU
IDGCMPID
1

TOB07

PDCIG01a

1

LENGTHLength

84

83.5

84.5

mm



2TOB07PDCIG01a2CIRCUMFCircumference24.824.625mm

3TOB07PDCIG01a3TBFLMASSTobacco Filler Mass783753814mg

4TOB07PDCIG01a4MOISTUREMoisture131214%

5TOB07PDCIG01a5TOCUTSIZTobacco Cut Size

22

20

24

cuts/in2


Burley tobacco

6TOB07PDCIG01a6TOCUTSIZTobacco Cut Size

27

25

29

mm


Reconstituted tobacco

7TOB07PDCIG01a7FLTRVENTFilter Ventilation

30

23

37

%



8TOB07PDCIG01a8TPNPLGTHTipping Paper Length313032mm

9TOB07PDCIG01a9CIGBPPORCigarette Base Paper PorosityNANANACORESTA Unit (Cu)

10TOB07PDCIG01a10CBPPERMCigarette Base Paper Permeability

50

45

55

CORESTA Unit (Cu)



11TOB07PDCIG01a11CBPPORCigarette Paper Band PorosityNANANACORESTA Unit (Cu) or cm2/s

12TOB07PDCIG01a12CPBPERMCigarette Paper Band Permeability100.213CORESTA Unit (Cu) or cm2/s

13TOB07PDCIG01a13CPBDIFFCigarette Paper Band DiffusivityNANANACORESTA Unit (Cu) or cm2/s

14TOB07PDCIG01a14CPBWIDCigarette Paper Band Width

7

6.7

7.3

mm



15TOB07PDCIG01a15CPBSPCCigarette Paper Band Space20

19.8

20.2

mm



16TOB07PDCIG01a16FLTREFFFilter Efficiency

NA

N/A

N/A

%



17TOB07PDCIG01a17DPFDenier Per Filament43.64.4

g/9000m

Jira
showSummaryfalse
serverIssue Tracker (JIRA)
serverId85506ce4-3cb3-3d91-85ee-f633aaaf4a45
keyTOBA-187



18TOB07PDCIG01a18TDENIERTotal Denier

30000

29100

30900

g/9000m



19TOB07PDCIG01a19FLTRDENFilter Density0.12340.1050.1419g/cm3

20TOB07PDCIG01a20FLTRLGTHFilter Length2524.525.5mm

21TOB07PDCIG01a21FLTPRDRPFilter Pressure Drop605169mm H2O

22TOB07PDCIG01a22TORODDENTobacco Rod Density0.26780.24370.2919g/cm3

23TOB07PDCIG01a23CIGPLGTHCigarette Paper Length535254mm

Nsvmeta
DomainPD
VariableLabelTypeCodelistRoleOrigin
IDGCMPIDIngredient or Component Identifiertext
Non-standard Record QualifierPredecessor

Finally, the Tobacco Product Testing (PT) domain is used to represent the actual results of testing the manufactured cigarette product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a required variable and is set to "DESIGN PARAMETER TESTING" for all records here. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only one replicate per parameter is shown. Note that PTREPNUM (repetition number) =1 for all rows.

...