Page History
The reference specifications introduces the Reference Dataset Structure. A Reference Dataset Structure dataset contains one record per combination of Stratum values. At least one stratum variable is required and up to 99 stratum variables can be present in a reference dataset. There may several reference datasets in a study. This section of the TIG defines the standard variables used in reference datasets.
Reference dataset names must have a prefix of RF. There are then up to 6 characters that should be used to make dataset name meaningful. However, In the ADaM standard there are currently no predefined dataset names besides for ADSL.
- Proposed names for the datasets in the example section are:
- RFBR (Reference Data for Birthrate)
- RFIP (Reference Data for Initial Population)
- RFMIGRAT (Reference Data for Migration Rates)
- RFMORT (Reference Data for Mortality Rates)
- RFTRANSP (Reference Data for Transition Prob)
The identifier variables associated with the reference values are captured in the STRTMy (Stratum y) variables. The actual values of the STRTMy variables are captured in the STRVALy (Stratum y Value) variables As many identifiers as necessary based on the source data should be captured in the reference dataset and the order of the stratum variables has no inherent meaning so ordering is not defined in this section. The convention of y is used as an index value indicating an integer with a value of 1-99 (as described in the ADaM standard section). There is no requirement that the stratum variables start with 1, nor must the variables use consecutive values. Some examples of stratum variables are Year, Sex, Race, Age, Transition type, and product.
...
Variable Name | Variable Label | Type | Codelist/ Controlled Terms | Core | CDISC Notes |
---|---|---|---|---|---|
STRTMy | Stratum y | Char | Req | Indicates stratification factors used when calculating the value of the input parameter. | |
STRVALy | Stratum y Value | Char | Req | Identifies the stratum with which the input parameter is associated. | |
INPRM | Input Parameter | Char | Perm | Indicate the calculated input parameter for the stratum or strata. | |
INPRMVAL | Input Parameter Value | Num | Req | This is the value of the input parameter. | |
INPRMU | Input Parameter Unit | Char | Perm | Unit associated with the input parameter value. | |
REFSRCE | Reference Data Source | Char | Perm | Information identifying the source of the reference data - this may be captured in the dataset or in the define file |
Pagenav |
---|