Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Dataset wrap
Namepd
Dataset2
RowSTUDYIDDOMAINSPTOBIDPDSEQPDPARMCDPDPARMPDVALTRGPDVALMINPDVALMAXPDVALU
1TOB09PDVAPE-Z27

1

DRWRSTDraw Resistance90.080.0120.0mm H2O
2TOB09PDVAPE-Z272PUFCNTPuff Count300290310
3TOB09PDVAPE-Z273CRTVOLCartridge Volume315mL
4TOB09PDVAPE-Z274HTELNUMNumber of Heating Elements111
5TOB09PDVAPE-Z275HTELGTHHeating Element Length32.73.3mm
6TOB09PDVAPE-Z276HTEDIAMHeating Element Diameter32.93.2mm
7TOB09PDVAPE-Z277HTELRSTHeating Element Resistance0.750.251.5ohm
8TOB09PDVAPE-Z278HTELRNGHeating Element Range175100250C
9TOB09PDVAPE-Z279HTELCFGHeating Element ConfigurationSPIRALSPIRALSPIRAL
10TOB09PDVAPE-Z2710BTVLTORG

Battery Voltage Operating Range

4.536V
11TOB09PDVAPE-Z2711BTCRTORG

Battery Current Operating Range

10006501600mAh
12TOB09PDVAPE-Z2712BATCAPCBattery Capacity11008003000mAh
13TOB09PDVAPE-Z2713BATNOMV

Battery Nominal Voltage

4.24.04.5V
14TOB09PDVAPE-Z2714BTCRTRTBattery Current Rating250020002800mA
15TOB09PDVAPE-Z2715BTCHTPLBattery Charging Temperature Limits200100315C
16TOB09PDVAPE-Z2716BTDCTMPLBattery Discharge Temperature Limits20-2060C
17TOB09PDVAPE-Z2717BTENDCVBattery End of Discharge Voltage3.02.03.5V
18TOB09PDVAPE-Z2718BTMXCHCBattery Maximum Charging Current242030mA
19TOB09PDVAPE-Z2719BTMXDCC

Battery Maximum Discharging Current

270024003000mA
20TOB09PDVAPE-Z2720BTULCHVBattery Upper Limits Charging Voltage4.24.14.3V
21TOB09PDVAPE-Z2721PDUVORPDU Voltage Operating Range3.73.24.2V
22TOB09PDVAPE-Z2722PDUCORPDU Current Operating Range12008501800mA
23TOB09PDVAPE-Z2723PDUWTORPDU Wattage Operating Range757080W
24TOB09PDVAPE-Z2724PDUTCTOFPDU Temperature Cut-off705565C
25TOB09PDVAPE-Z2725AIRFLRTAirflow Rate720700740L/min
26TOB09PDVAPE-Z2726PDUCRCOFPDU Current Cut-off352050mA
27TOB09PDVAPE-Z2727INHAERTInhaled Aerosol Temperature373540C
28TOB09PDVAPE-Z2728VENTLTNVentilation504060%
29TOB09PDVAPE-Z2729ELQDVISCE-Liquid Viscosity500751130mPa/s
30TOB09PDVAPE-Z2730ELQDVOLE-liquid Volume6010120mL
31TOB09PDVAPE-Z2731PNUMCNCParticle Number Concentration5001081010/cm3
32TOB09PDVAPE-Z2732CTMDDIAMCount Median Diameter200150250nm
33TOB09PDVAPE-Z2733PM2.5Particulate Matter 2.5251235ug/m3

Finally, the Tobacco Product Testing (PT) domain is used to represent the actual results of testing the manufactured ENDS product for conformance to the tobacco product design parameters shown in PD above. PTCAT is a required variable and is set to "DESIGN PARAMETER TESTING" for all records here. Typically, applicants would submit data on each parameter in multiple replicates. For simplicity of review, only one replicate per parameter is shown. Note that PTREPNUM (repetition number) =1 for all rows. 

...