These product issues and events are represented in the Tobacco Product Issues Events and Events Malfunctions Domain (PIEM).  Events not specifically associated with the product device should not be represented in this PI EM domain.     

The sponsor used a standardized or dictionary-derived text for the description of an issue or events. CDISC does not provide information on what standardized or dictionary-derived text should be used). 

The sponsor decided to use the International Medical Device Regulators Forum (IMDRF) document “IMDRF Terminologies for Categorized Adverse Event Reporting (AER): Terms, Terminology Structure and Codes. Annex A ( 2022) provides the medical problem codes. The name and version of the dictionary used to map terms must be provided in a Define.XML ExternalCodeList element. PIDECODE EMDECOD was the Level 3 IMDRF term. Non-standard variables were used to represent the various coding level variables defined in the dictionary. 

( NOTE: Meta Example to be confirmed with someone - RM. )

Example SUPPPI  SUPPEM  Variable Metadata

Variable Label Type Codelist
PIIMDRCDEMIMDRCDIMDRF CodetextIMDRFANNEXA 
PIIMDRFL2EMIMDRFL2IMDRF Level 2textIMDRFANNEXA
PIIMDRFL1EMIMDRFL1IMDRF Level 1textIMDRFANNEXA

...

Codelist

External Dictionary Name

Dictionary Version

Reference

IMDRFANNEXA IMDRF Terminologies for Categorized Adverse Event Reporting (AER): Terms, Terminology Structure and Codes : Annex A 

Release Number: 2022

https://www.imdrf.org/consultations/imdrf-terminologies-categorized-adverse-event-reporting-aer-terms-terminology-structure-and-codes

The PI EM dataset is shown below. 

Dataset wrap
NamePIEM
Dataset2

Row

STUDYID

DOMAIN

USUBJID

SPTOBID

PISEQEMSEQ

PILNKIDEMLNKID

PITERMEMTERM

PIDECODEMDECOD

PIMODIFYEMMODIFY

PIACNDEVEMACNDEV

PIPATTEMPATT

PISTDTCEMSTDTC

1

TB123

PIEM

2029

VAPE-Z01

1


Broken Heater

Mechanical Problem

Mechanical Problem

DEVICE REPLACED

SINGLE

2009-12-28

2

TB123

PIEM

1059

VAPE-Z01

1


Won’t charge

Charging Problem

Charging Problem

BATTERY REPLACED

SINGLE

2009-01-05

3

TB123

PIEM

3067

VAPE-Z01

1

1

Battery Malfunction

Battery Problem

Battery Problem

BATTERY REPLACED

INTERMITTENT

2009-01-05

Below is the dataset, SUPPPISUPPEM, used to represent the non-standad varibables used for coding the issue or event. The parent domain (RDOMAIN) is PIEM, and IDVAR is PISEQEMSEQ. QNAM holds the name of the supplemental qualifier variable being defined. This only shows the data for subject 2029. The data recorded in QVAL applies to the subject’s records, where IDVAR (PISEQEMSEQ) equals the value specified in IDVARVAL. 

Dataset wrap
NamesuppPIsuppem
Dataset2
RowSTUDYIDRDOMAINUSUBJIDIDVARIDVARVALQNAMQLABELQVALQORIGQEVAL
1TB123PIEM2029PISEQEMSEQ1PIIMDRCDEMIMDRCDIMDR CodeAO5ASSIGNED
2TB123PIEM2029PISEQEMSEQ1PIIMDRL2EMIMDRL2IMDR Level 2Mechanical ProblemASSIGNED
3TB123PIEM2029PISEQEMSEQ1PIIMDRL1EMIMDRL1IMDR Level 1Mechanical ProblemASSIGNED

...

The RELREC dataset was used to record the relationship between the Tobacco Product Issues Events and Events Malfunctions (PIEM) dataset and any reported AE represented in the AE dataset. 

Expand
titlerelrec.xpt

Row

STUDYID

RDOMAIN

USUBJID

IDVAR

IDVARVAL

RELTYPE

RELID

1TB005PXXEM
PILNKIDEMLNKID
ONEAEPI1AEEM1
2TB005AE
AELNKID