Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Dataset wrap
Namept
Rowcaps
Rows 1-32:Show the tobacco design parameter specification test and the result in ORRES (needs populated).
Row 28:Shows the design parameter specification test condition of 20 degrees Celsius using the TTTSTCND variable for the E-Liquid Viscosity test.
Dataset2
RowSTUDYIDDOMAINSPTOBIDPTSEQPTREFIDPTTESTCDPTTESTPTTSTCNDPTCATPTSCATPTORRESPTORRESUPTSTRESCPTSTRESNPTSTRESUPTREPNUMPTTPTPTTPTNUM
1TOB09PTVAPE-Z27

1


DRWRSTDraw Resistance
DESIGN PARAMETER TESTING

mm H2O

mm H2O1Week 01
2TOB09PTVAPE-Z272
PUFCNTPuff count (for full tank/cartridge)
DESIGN PARAMETER TESTING

NUMBER COUNT

NUMBER COUNT1Week 01
3TOB09PTVAPE-Z273
CRTVOLCartridge volume
DESIGN PARAMETER TESTING

mL

mL1Week 01
4TOB09PTVAPE-Z274
HTELNUMNumber of heating elements
DESIGN PARAMETER TESTING

NUMBER COUNT

NUMBER COUNT1Week 01
5TOB09PTVAPE-Z275
HTELGTHHeating element length
DESIGN PARAMETER TESTING

mm

mm1Week 01
6TOB09PTVAPE-Z276
HTELRSTHeating element resistance
DESIGN PARAMETER TESTING

ohm

ohm1Week 01
7TOB09PTVAPE-Z277
HTELRNGHeating element range
DESIGN PARAMETER TESTING

C

C1Week 01
8TOB09PTVAPE-Z278
HTELCFGHeating element configuration
DESIGN PARAMETER TESTING





1Week 01
9TOB09PTVAPE-Z279
BTVLTORGBattery voltage operating range
DESIGN PARAMETER TESTING

V

V1Week 01
10TOB09PTVAPE-Z2710
BTCRTORGBattery current operating range
DESIGN PARAMETER TESTING

mAh

mAh1Week 01
11TOB09PTVAPE-Z2711
BATCAPCBATCAPABattery capacity
DESIGN PARAMETER TESTING

mAh

mAh1Week 01
12TOB09PTVAPE-Z2712
BATNOMVBattery nominal voltage
DESIGN PARAMETER TESTING

V

V1Week 01
13TOB09PTVAPE-Z2713
BTCRTRTBattery Current Rating
DESIGN PARAMETER TESTING

mA


1Week 01
14TOB09PTVAPE-Z2714
BTCHTPLBattery Charging Temperature Limits
DESIGN PARAMETER TESTING

C


1Week 01
15TOB09PTVAPE-Z2715
BTDCTMPLBattery Discharge Temperature Limits
DESIGN PARAMETER TESTING

C


1Week 01
16TOB09PTVAPE-Z2716
BTENDCVBattery end of discharge voltage
DESIGN PARAMETER TESTING

V


1Week 01
17TOB09PTVAPE-Z2717
BTMXCHCBattery maximum charging current
DESIGN PARAMETER TESTING

mA


1Week 01
18TOB09PTVAPE-Z2718
BTMXDCCBattery maximum discharging current
DESIGN PARAMETER TESTING

mA


1Week 01
19TOB09PTVAPE-Z2719
BTULCHVBattery upper limits charging voltage
DESIGN PARAMETER TESTING

V


1Week 01
20TOB09PTVAPE-Z2720
PDUVORPower Delivery Unit (PDU) voltage operating range
DESIGN PARAMETER TESTING

V


1Week 01
21TOB09PTVAPE-Z2721
PDUCORPDU current operating range
DESIGN PARAMETER TESTING

mA


1Week 01
22TOB09PTVAPE-Z2722
PDUWTORPDU wattage operating range
DESIGN PARAMETER TESTING

W


1Week 01
23TOB09PTVAPE-Z2723
PDUTCTOFPDU temperature cut-off (if applicable)
DESIGN PARAMETER TESTING

C


1Week 01
24TOB09PTVAPE-Z2724
AIRFLRTAirflow rate
DESIGN PARAMETER TESTING

L/min


1Week 01
25TOB09PTVAPE-Z2725
PDUCRCOFPDU current cut-off (if applicable)
DESIGN PARAMETER TESTING

mA


1Week 01
26TOB09PTVAPE-Z2726
INHAERTInhaled aerosol temperature
DESIGN PARAMETER TESTING

C


1Week 01
27TOB09PTVAPE-Z2727
VENTLTNVentilation
DESIGN PARAMETER TESTING

%


1Week 01
28TOB09PTVAPE-Z2728
ELQDVISCE-Liquid viscosityTest performed at 20 degrees CelsiusDESIGN PARAMETER TESTING





1Week 01
29TOB09PTVAPE-Z2729
ELQDVOLE-liquid volume
DESIGN PARAMETER TESTING

mL


1Week 01
30TOB09PTVAPE-Z2730
PNUMCNCParticle number concentration
DESIGN PARAMETER TESTING

#/cm3


1Week 01
31TOB09PTVAPE-Z2731
CTMDDIAMCount median diameter
DESIGN PARAMETER TESTING

nm


1Week 01
32TOB09PTVAPE-Z2732
PMPM 2.5
DESIGN PARAMETER TESTING

ug/m3


1Week 01