Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Expand
titletx.xpt (trial sets)
  • During CT definition/reviews will decide appropriate TXPARM and TXVAL; Treatment duration may be controlled;  For now, we just include good example values based on our experience
  • Assumption: The Trial Sets (TX) domain provides the list of distinct sets of subjects having different experimental factors, treatment factors, inherent characteristics, or distinct sponsor designations as specified in the trial design.
  • Where is TK6 cell type?  is this test system (see below)
    • needs to be allowed to vary down to the well level / result level

A1:


A2:                                   

TSTS
RowSTUDYIDASSAYIDDOMAINSETCD
SET (what sponsor calls it)
TXSEQTXPARMCDTXPARMTXVAL

123MNvitTX

A1

(table 1, row 1, ST exposure with S9)

ST+S91METACTMetabolic Activation  (this is the type of activation used)+S9

123MNvitTXA1ST+S92METACTFLY/N presence of metabolic activation (this indicates that metabolic activation was used)Y

123MNvitTXA1ST+S93TRTDRTRGTreatment Duration target. (how do we show 3-6 hour range?  start/end, target and tolerance?, one text field not-analyzable)3

123MNvitTXA1ST+S94TRTDRTOLTreatment Duration Tolerance

123MNvitTXA1ST+S95TRTDURUTreatment Duration Unit (this is for both TRTDURT, TRTDURTOL)H

123MNvitTXA1ST+S96INTRVN

name of the intervention article

(Tobacco ProdA, Bleomycin or Cyclophosphamid A)

Tobacco ProdA

123MNvitTXA1ST+S97ITVTYPE

type of intervention article

choices of values:  product; negative control; positive control

Product

123MNvitTXA1ST+S98ITVCONCConcentration of intervention article0

123MNvitTXA1ST+S99ITVCONCUConcentration Unitug/ml

123MNvitTSTXA1ST+S910SPDEVIDSponsor defined device identifierPUFFMASTER3K

123MNvitTSTXA1ST+S911DUREFIDSmoke RegimenMedium Intensity Regimen

123MNvitTX

A2

(table 1, row 2)


1METACTMetabolic Activation  (should there be two parms? Presence, type)?+S9

123MNvitTXA2
2METACTFLY/N presence of metabolic activation (this indicates that metabolic activation was used)Y

123MNvitTXA2
3TRTDRTRGTreatment Duration target. (how do we show 3-6 hour range?  start/end, target and tolerance?, one text field not-analyzable)3

123MNvitTXA2
4TRTDRTOLTreatment Duration Tolerance

123MNvitTXA2
5TRTDURUTreatment Duration Unit (this is for both TRTDURT, TRTDURTOL)H

123MNvitTXA2
6INTRVNname of the intervention articleTobacco ProdA

123MNvitTXA2
7ITVTYPEtype of intervention articleProduct

123MNvitTXA2
8ITVCONCConcentration of i a 1250

123MNvitTXA2
9ITVCONCUConcentration Unitug/ml

123MNvitTXA2
10SPDEVIDSponsor defined device identifierPUFFMASTER2023

123MNvitTXA2
11DUREFIDSmoke RegimenHigh Intensity Regimen
...








Expand
titledu.xpt smoke regimen definition (a findings domain for device in-use properties)

 We use DU for smoking regimen. Note that a separate DI dataset will be needed to show identifying parameters of the "PUFFMASTER3K" smoking machine, but is currently not shown for brevity.

  • Details of the smoking regimen are represented as device in-use properties, linked to the stability data in PT above by matching values of PTREFID/DUREFID = "Medium Intensity Regimen" (We will update with a realistic value for the regimen, with input).
  • Smoking regimen is represented in --REFID (we made up a value of "Medium Intensity Regimen"; we can update with something realistic)
  • The smoking regimen is carried out by the smoking machine/device shown in SPDEVID, Sponsor defined device identifier, "PUFFMASTER3K"
  • Do we need both SPDEVID AND DUREFID?

du.xpt

Row

STUDYID

DOMAIN

SPDEVID

DUSEQ

DUREFID

DUGRPID

DUTESTCD

DUTEST

DUORRES

DUORRESU

DUSTRESC

DUSTRESN

DUSTRESU

1123DUPUFFMASTER3K1Medium Intensity Regimen
PUFFPROFPuff ProfileSQUARE
SQUARE

2123DUPUFFMASTER3K2Medium Intensity Regimen

PUFFDUR

Puff Duration

1.25

sec

1.25

1.25

sec

3123DUPUFFMASTER3K3Medium Intensity Regimen

PUFFINT

Puff Interval

3

PUFF/min

3

3

PUFF/min

4123DUPUFFMASTER3K4Medium Intensity Regimen

PUFFBLCK

Puff Block

25

%

25

25

%

5123DUPUFFMASTER3K5Medium Intensity Regimen
NUMPUFFTotal Number of Puffs

200

PUFF

200

200

PUFF

6123DUPUFFMASTER3K6Medium Intensity Regimen
PUFFVOLPuff Volume

10

mL

10

10

mL

7123DUPUFFMASTER3K7Medium Intensity Regimen
PUFFRNGPuff Range

100-200


100-200



8123DUPUFFMASTER3K8Medium Intensity Regimen1PUFFPAUSPuff Pause

60

s

60

60

s

9123DUPUFFMASTER3K9Medium Intensity Regimen1PUFFPINTPuff Pause Interval

10

PUFF

10

10

PUFF

10123DUPUFFMASTER20231

Canadian Intense Regime


PUFFPROFPuff ProfileSQUARE
SQUARE

11123DUPUFFMASTER20232Canadian Intense Regime

PUFFDUR

Puff Duration

2.00

sec

2.00

2.00

sec

12123DUPUFFMASTER20233Canadian Intense Regime

PUFFINT

Puff Interval

4

PUFF/min

4

4

PUFF/min

13123DUPUFFMASTER20234

Canadian Intense Regime


PUFFBLCK

Puff Block

0

%

0

0

%

14123DUPUFFMASTER20235Canadian Intense Regime
NUMPUFFTotal Number of Puffs

200

PUFF

200

200

PUFF

15123DUPUFFMASTER20236Canadian Intense Regime
PUFFVOLPuff Volume

10

mL

10

10

mL

16123DUPUFFMASTER20237

Canadian Intense Regime


PUFFRNGPuff Range

100-200


100-200



17123DUPUFFMASTER20238Canadian Intense Regime1PUFFPAUSPuff Pause

60

s

60

60

s

18123DUPUFFMASTER20239Canadian Intense Regime1PUFFPINTPuff Pause Interval

10

PUFF

10

10

PUFF

...