In this study, subjects were randomized to one of three nicotine dosage levels. At the baseline visit (Week 0), they receiving received an ENDS device that used used 0, 8 or 24 mg/ml nicotine liquid. Self-reported daily cigarette consumption were was recorded for each day of the study for 4 weeks. The subjects were supplied replacement nicotine cartridges at each weekly visit. The sponsor used an electronic diary application to track when the cartridges were inserted and removed, and the daily number of cigarettes smoked. The subject used their normal brand cigarettes, and these were not supplied by the sponsor, and not considered a study product. Each cartridge was 8 mL. No other nicotine replacement products were allowed to be used. Multiple cartridges were dispensed at a visit.
The sponsor reported represented the cigarettes used in the in the SU domain. The number of cigarettes smoked for each day of the study after the first visit were represented. If no cigarettes were smoked, a 0 was recorded as the data was collected. Only a few rows are shown.
Dataset wrap |
---|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | SUSEQ | SUTRT | SUCAT | SUDOSE | SUDOSU | SUDOSFRQ | SUSTDTC | SUENDTC |
---|
1 | TENDS01 | SU | TEN01001 | 1 | CIGARETTES | TOBACCO | 6 | CIGARETTE | PER DAYQD | 2020-06-27 | 2020-06-27 | 2 | TENDS01 | SU | TEN01001 | 2 | CIGARETTES | TOBACCO | 1 | CIGARETTE | PER DAYQD | 2020-06-28 | 2020-06-28 | 3 | TENDS01 | SU | TEN01001 | 3 | CIGARETTES | TOBACCO | 0 | CIGARETTE | PER DAYQD | 2020-06-29 | 2020-06-29 |
|
|
A Product Accountability domain was submitted to represent dispensed and returned amounts. The ENDS product used in the study was assigned a Sponsor Tobacco Product Identifier (VAPE-Z27) and each cartridge had a uniquely assigned number. This unique number was represented in DAREFID. Multiple cartridges were dispensed at weekly visits, but each cartridge was tracked. At each weekly visit, all previously dispended dispensed cartridges were returned, and new cartridges dispensed. Cartridges were replaced at each visit. DADTC are the visit dates when the cartridge was returned or dispensed. Cartridges not used were record recorded as having the full volume returned.
Dataset wrap |
---|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | DASEQ | SPTOBID | DAREFID | DATESTCD | DATEST | DACAT | DAORRES | DAORRESU | DASTRESC | DASTRESN | DASTRESU | VISITNUM | DADTC |
---|
1 | TENDS01 | DA | TEN01001 | | VAPE-Z27 | CRT8754 | DISPAMT | Dispensed Amount | STUDY PRODUCT | 8 | mL | 8 | 8 | mL | 1 | 2004-06-26 | 2 | TENDS01 | DA | TEN01001 | | VAPE-Z27 | CRT8768 | DISPAMT | Dispensed Amount | STUDY PRODUCT | 8 | mL | 8 | 8 | mL | 1 | 2004-06-26 | 3 | TENDS01 | DA | TEN01001 | | VAPE-Z27 | CRT8769 | DISPAMT | Dispensed Amount | STUDY PRODUCT | 8 | mL | 8 | 8 | mL | 1 | 2004-06-26 | 4 | TENDS01 | DA | TEN01001 | | VAPE-Z27 | CRT8754 | RETAMT | Returned Amount | STUDY PRODUCT | 2 | mL | 626 | 2 | mL | 2 | 2020-07-06 | 2 | TENDS01 | DA | TEN01001 | | VAPE-Z27 | CRT8768 | RETAMT | Returned Amount | STUDY PRODUCT | 1.6 | mL | 8 | 1.6 | 1.68 | mL | 2 | 2020-07-06 | 3 | TENDS01 | DA | TEN01001 | | VAPE-Z27 | CRT8769 | RETAMT | Returned Amount | STUDY PRODUCT | 8 | mL | 8 | 8 | mL | 2 | 2020-07-06 | 5 | TENDS01 | DA | TEN01001 | | VAPE-Z27 | CRT9756 | DISPAMT | Dispensed Amount | STUDY PRODUCT | 8 | mL | 8 | 8 | mL | 2 | 2020-07-06 | 6 | TENDS01 | DA | TEN01001 | | VAPE-Z27 | CRT9756 | RETAMT | Returned Amount | STUDY PRODUCT | 1.0 | mL | 1.30 | 1.30 | mL | 3 | 2020-07-10 |
|
|
Since the data in Exposure as collected (EC) would be practically identically identical to the summarized EX domain, the sponsor did not submit the EC domain. The sponsor unblinded the study before creating the EX domain. The unblinded product name is provided in EXTRT, here a dummy name is used for the tobacco product.
...
Dataset wrap |
---|
|
Dataset2 |
---|
Row | STUDYID | DOMAIN | USUBJID | EXSEQ | SPTOBID | EXREFID | EXTRT | EXDOSE | EXDOSU | EXROUTE | EXPSTRG | EXPSTRGU | EXSTDTC | EXENDTC |
---|
1 | TENDS01 | EX | TEN01001 | 1 | VAPE-Z27 | CRT8754 | e-nicotine liquid | 6 | mL | INHALED | 8 | mg/mL | 2020-06-26 | 2020-07-01 | 2 | TENDS01 | EX | TEN01001 | 2 | VAPE-Z27 | CRT8768 | e-nicotine liquid | 6.4 | mL | INHALED | 8 | mg/mL | 2020-07-01 | 2020-07-06 | 3 | TENDS01 | EX | TEN01001 | 3 | VAPE-Z27 | CRT9756 | e-nicotine liquid | 7 | mL | INHALED | 8 | mg/mL | 2020-07-06 | 2020-07-10 | 3 | TENDS01 | EX | TEN01001 | 4 | VAPE-Z27 | CRT9778 | e-nicotine liquid | 8 | mL | INHALED | 8 | mg/mL | 2020-07-10 | 2020-07-14 | 4 | TENDS01 | EX | TEN10002 | 1 | VAPE-Z27 | CRT8000 | e-nicotine liquid | 5 | mL | INHALED | 240 | mg/mL | 2020-09-01 | 2020-09-07 | 5 | TENDS01 | EX | TEN10002 | 2 | VAPE-Z27 | CRT9006 | e-nicotine liquid | 7 | mL | INHALED | 240 | mg/mL | 2020-09-07 | 2020-09-14 | 6 | TENDS01 | EX | TEN10002 | 3 | VAPE-Z27 | CRT9008 | e-nicotine liquid | 8 | mL | INHALED | 240 | mg/mL | 2020-09-14 | 2020-09-21 | 7 | TENDS01 | EX | TEN10002 | 4 | VAPE-Z27 | CRT9017 | e-nicotine liquid | 6 | mL | INHALED | 240 | mg/mL | 2020-09-21 | 2020-09-28 | 8 | TENDS01 | EX | TEN10002 | 5 | VAPE-Z27 | CRT9089 | e-nicotine liquid | 7 | mL | INHALED | 240 | mg/mL | 2020-09-28 | 2020-09-31 | 9 | TENDS01 | EX | TEN10002 | 6 | VAPE-Z27 | CRT9128 | e-nicotine liquid | 8 | mL | INHALED | 240 | mg/mL | 2020-10-31 | 2020-10-08 | 10 | TENDS01 | EX | TEN10002 | 7 | VAPE-Z27 | CRT6868 | e-nicotine liquid | 6.7 | mL | INHALED | 240 | mg/mL | 2020-10-08 | 2020-10-15 | 11 | TENDS01 | EX | TEN10002 | 8 | VAPE-Z27 | CRT7868 | e-nicotine liquid | 5.5 | mL | INHALED | 240 | mg/mL | 2020-10-15 | 2020-10-22 |
|
|